Literature DB >> 29607723

Complete nasal obstruction secondary to pacemaker insertion.

T Lloyd Jones1, V B Wreesmann1, E Nilssen1, J Hilton1, S M Hayes1.   

Abstract

We present the case of a 71-year-old man who presented to the ear, nose and throat department with complete nasal obstruction and facial plethora on bending forward. Clinical examination was positive for Pemberton's sign. Computed tomography and ultrasonography demonstrated bilateral brachiocephalic vein thrombosis secondary to pacemaker insertion. This case highlights a novel complication of pacemaker insertion.

Entities:  

Keywords:  Brachiocephalic vein thrombosis; Nasal obstruction; Pacemaker

Mesh:

Year:  2018        PMID: 29607723      PMCID: PMC5956605          DOI: 10.1308/rcsann.2018.0055

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  3 in total

1.  Managing superior vena cava syndrome as a complication of pacemaker implantation: a pooled analysis of clinical practice.

Authors:  Robert F Riley; Steffen E Petersen; John D Ferguson; Yaver Bashir
Journal:  Pacing Clin Electrophysiol       Date:  2009-12-28       Impact factor: 1.976

2.  The superior vena cava syndrome: clinical characteristics and evolving etiology.

Authors:  Todd W Rice; R Michael Rodriguez; Richard W Light
Journal:  Medicine (Baltimore)       Date:  2006-01       Impact factor: 1.889

3.  Pemberton's sign: explained nearly 70 years later.

Authors:  Elena A De Filippis; Amin Sabet; Maryellen R M Sun; Jeffrey R Garber
Journal:  J Clin Endocrinol Metab       Date:  2014-03-19       Impact factor: 5.958

  3 in total