Literature DB >> 29607538

Free-breathing cine DENSE MRI using phase cycling with matchmaking and stimulated-echo image-based navigators.

Xiaoying Cai1, Frederick H Epstein1,2.   

Abstract

PURPOSE: This study aimed to develop a self-navigated method for free-breathing spiral cine displacement encoding with stimulated echoes (DENSE), a myocardial strain imaging technique that uses phase-cycling for artifact suppression. The method needed to address 2 consequences of motion for DENSE: striping artifacts from incomplete suppression of the T1 -relaxation echo and blurring.
METHODS: The method identifies phase-cycled spiral interleaves at matched respiratory phases by minimizing the residual signal due to T1 relaxation after phase-cycling subtraction. Next, the method reconstructs image-based navigators from matched phase-cycled interleaves that are comprised of the stimulated echo (ste-iNAVs). Ste-iNAVs are used for motion estimation and compensation of k-space data. The method was demonstrated in phantoms and compared to diaphragm-based navigator (dNAV) and conventional iNAV (c-iNAV) methods for the reconstruction of free-breathing volunteer data sets (N = 10).
RESULTS: Phantom experiments demonstrated that the proposed method removes striping artifacts and blurring due to motion. Volunteer results showed that respiratory motion measured by ste-iNAVs was better correlated than c-iNAVs to dNAV data (R2  = 0.82 ± 0.03 vs. 0.70 ± 0.05, P < 0.05). Match-making reconstructions of free-breathing data sets achieved lower residual T1 -relaxation echo energy (1.04 ± 0.01 vs. 1.18 ± 0.04 for dNAV and 1.18 ± 0.03 for c-iNAV, P < 0.05), higher apparent SNR (11.93 ± 1.05 vs. 10.68 ± 1.06 for dNAV and 10.66 ± 0.99 for c-iNAV, P < 0.05), and better phase quality (0.147 ± 0.012 vs. 0.166 ± 0.017 for dNAV, P = 0.06, and 0.168 ± 0.015 for c-iNAV, P < 0.05) than dNAV and c-iNAV methods.
CONCLUSION: For free-breathing cine DENSE, the proposed method addresses both types of breathing-induced artifacts and provides better quality images than conventional dNAV and iNAV methods.
© 2018 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  cardiac MRI; cine DENSE; free-breathing; image-based navigator; self-navigating

Mesh:

Year:  2018        PMID: 29607538      PMCID: PMC6107388          DOI: 10.1002/mrm.27199

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  36 in total

1.  Adaptive reconstruction of phased array MR imagery.

Authors:  D O Walsh; A F Gmitro; M W Marcellin
Journal:  Magn Reson Med       Date:  2000-05       Impact factor: 4.668

2.  Generalized spatiotemporal myocardial strain analysis for DENSE and SPAMM imaging.

Authors:  Alistair A Young; Bo Li; Robert S Kirton; Brett R Cowan
Journal:  Magn Reson Med       Date:  2011-08-29       Impact factor: 4.668

3.  In vivo 3T spiral imaging based multi-slice T(1rho) mapping of knee cartilage in osteoarthritis.

Authors:  Xiaojuan Li; Eric T Han; C Benjamin Ma; Thomas M Link; David C Newitt; Sharmila Majumdar
Journal:  Magn Reson Med       Date:  2005-10       Impact factor: 4.668

4.  A phase rotation scheme for achieving very short echo times with localized stimulated echo spectroscopy.

Authors:  Jack Knight-Scott; Dattesh D Shanbhag; S Andrea Dunham
Journal:  Magn Reson Imaging       Date:  2005-10-13       Impact factor: 2.546

5.  Balanced multipoint displacement encoding for DENSE MRI.

Authors:  Xiaodong Zhong; Patrick A Helm; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

6.  Imaging left-ventricular mechanical activation in heart failure patients using cine DENSE MRI: Validation and implications for cardiac resynchronization therapy.

Authors:  Daniel A Auger; Kenneth C Bilchick; Jorge A Gonzalez; Sophia X Cui; Jeffrey W Holmes; Christopher M Kramer; Michael Salerno; Frederick H Epstein
Journal:  J Magn Reson Imaging       Date:  2017-01-09       Impact factor: 4.813

7.  Heart wall motion: improved method of spatial modulation of magnetization for MR imaging.

Authors:  L Axel; L Dougherty
Journal:  Radiology       Date:  1989-08       Impact factor: 11.105

8.  Spectrally-Presaturated Modulation (SPM): An efficient fat suppression technique for STEAM-based cardiac imaging sequences.

Authors:  Ahmed S Fahmy; El-Sayed H Ibrahim; Nael F Osman
Journal:  Magn Reson Imaging       Date:  2016-11-05       Impact factor: 2.546

9.  Comparison of Displacement Encoding With Stimulated Echoes to Magnetic Resonance Feature Tracking for the Assessment of Myocardial Strain in Patients With Acute Myocardial Infarction.

Authors:  Yoshitaka Goto; Masaki Ishida; Shinichi Takase; Andreas Sigfridsson; Mio Uno; Motonori Nagata; Yasutaka Ichikawa; Kakuya Kitagawa; Hajime Sakuma
Journal:  Am J Cardiol       Date:  2017-02-28       Impact factor: 2.778

10.  A dual-projection respiratory self-gating technique for whole-heart coronary MRA.

Authors:  Peng Lai; Andrew C Larson; Xiaoming Bi; Renate Jerecic; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2008-09       Impact factor: 4.813

View more
  1 in total

1.  Suppression of artifact-generating echoes in cine DENSE using deep learning.

Authors:  Mohamad Abdi; Xue Feng; Changyu Sun; Kenneth C Bilchick; Craig H Meyer; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2021-05-22       Impact factor: 3.737

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.