Literature DB >> 29606632

Patient Perceptions of Breast Cancer Risk in Imaging-Detected Low-Risk Scenarios and Thresholds for Desired Intervention: A Multi-Institution Survey.

Lars J Grimm1, Rebecca A Shelby2, Emily E Knippa3, Eun L Langman4, Lauren S Miller5, Beth E Whiteside6, Mary Scott C Soo4.   

Abstract

PURPOSE: To determine women's perceptions of breast cancer risk and thresholds for desiring biopsy when considering BI-RADS 3 and 4A scenarios and recommendations, respectively.
MATERIALS AND METHODS: Women presenting for screening mammography from five geographically diverse medical centers were surveyed. Demographic information and baseline anxiety were queried. Participants were presented with scenarios of short-term imaging follow-up recommendations (ie, BI-RADS 3) and biopsy recommendations (ie, BI-RADS 4A) for low-risk mammographic abnormalities and asked to estimate their breast cancer risk for each scenario. Participants reported the threshold (ie, likelihood of cancer) where they would feel comfortable undergoing short-term imaging follow-up and biopsy and their anticipated regret for choosing short-term follow-up versus biopsy.
RESULTS: Analysis of 2,747 surveys showed that participants estimated breast cancer risk of 32.8% for a BI-RADS 3 and 41.1% for a BI-RADS 4A scenarios are significantly greater rates than clinically established rates (<2% [P < .001] and 2%-10% [P < .001], respectively). Over one-half (55.4%) of participants reported they would never want imaging follow-up if there was any chance of cancer; two-thirds (66.2%) reported they would desire biopsy if there was any chance of cancer. Participants reported greater anticipated regret (P < .001) and less relief and confidence (P < .001) with the decision to undergo follow-up imaging versus biopsy.
CONCLUSION: Women overestimate breast cancer risk associated with both BI-RADS 3 and 4A scenarios and desire very low biopsy thresholds. Greater anticipated regret and less relief and confidence was reported with the choice to undergo short-term imaging follow-up compared with biopsy.
Copyright © 2018 American College of Radiology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  BI-RADS; Breast cancer; patient perception; risk; shared decision making

Mesh:

Year:  2018        PMID: 29606632     DOI: 10.1016/j.jacr.2018.02.010

Source DB:  PubMed          Journal:  J Am Coll Radiol        ISSN: 1546-1440            Impact factor:   5.532


  2 in total

1.  Evaluation of Real-world Data for Breast-MRI BI-RADS IV Lesions.

Authors:  Jens Hachenberg; Christian Eichler; Lena Steinkasserer; Wolfram Malter; Fabinshy Thangarajah; Mathias Warm; Axel Gossmann; Markus Brod; Caroline Pahmeyer
Journal:  In Vivo       Date:  2022 Sep-Oct       Impact factor: 2.406

Review 2.  Exosomes: A Promising Avenue for the Diagnosis of Breast Cancer.

Authors:  Yiming Meng; Jing Sun; Xiaonan Wang; Tingting Hu; Yushu Ma; Cuicui Kong; Haozhe Piao; Tao Yu; Guirong Zhang
Journal:  Technol Cancer Res Treat       Date:  2019-01-01
  2 in total