Krishna R Cidambi1, Nicholas Robertson2, Camille Borges2, Nader A Nassif2, Steven L Barnett2. 1. Department of Orthopedic Surgery, Hoag Orthopedic Institute, Irvine, CA; Department of Orthopaedic Surgery, University of California, San Diego, San Diego, CA. 2. Department of Orthopedic Surgery, Hoag Orthopedic Institute, Irvine, CA.
Abstract
BACKGROUND: For establishing femoral component position, gap-balancing (GB) and measured resection (MR) techniques were compared using a force sensor. METHODS: Ninety-one patients were randomized to undergo primary total knee arthroplasty using either MR (n = 43) or GB (n = 48) technique using a single total knee arthroplasty design. GB was performed with an instrumented tensioner. Force sensor data were obtained before the final implantation. RESULTS:GB resulted in greater range of femoral component rotation vs MR (1.5° ± 2.9° vs 3.1° ± 0.5°, P < .05) and posterior condylar cut thickness medially (10.2 ± 2.0 mm vs 9.0 ± 1.3 mm) and laterally (8.5 ± 1.9 mm vs 6.4 ± 1.0 mm). Force sensor data showed a decreased intercompartmental force difference at full flexion in GB (.8 ± 2.3 vs 2.0 ± 3.3u, 1u ≈ 15 N, P < .05). CONCLUSION:GB resulted in a greater range of femoral component rotation and thicker posterior condylar cuts resulting in an increased flexion space relative to MR. Intercompartmental force difference trended toward a more uniform distribution between full extension and full flexion in the GB vs MR group.
RCT Entities:
BACKGROUND: For establishing femoral component position, gap-balancing (GB) and measured resection (MR) techniques were compared using a force sensor. METHODS: Ninety-one patients were randomized to undergo primary total knee arthroplasty using either MR (n = 43) or GB (n = 48) technique using a single total knee arthroplasty design. GB was performed with an instrumented tensioner. Force sensor data were obtained before the final implantation. RESULTS:GB resulted in greater range of femoral component rotation vs MR (1.5° ± 2.9° vs 3.1° ± 0.5°, P < .05) and posterior condylar cut thickness medially (10.2 ± 2.0 mm vs 9.0 ± 1.3 mm) and laterally (8.5 ± 1.9 mm vs 6.4 ± 1.0 mm). Force sensor data showed a decreased intercompartmental force difference at full flexion in GB (.8 ± 2.3 vs 2.0 ± 3.3u, 1u ≈ 15 N, P < .05). CONCLUSION:GB resulted in a greater range of femoral component rotation and thicker posterior condylar cuts resulting in an increased flexion space relative to MR. Intercompartmental force difference trended toward a more uniform distribution between full extension and full flexion in the GB vs MR group.
Authors: Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann Journal: Knee Surg Sports Traumatol Arthrosc Date: 2020-04-30 Impact factor: 4.342