Literature DB >> 29602537

Intraoperative Comparison of Measured Resection and Gap Balancing Using a Force Sensor: A Prospective, Randomized Controlled Trial.

Krishna R Cidambi1, Nicholas Robertson2, Camille Borges2, Nader A Nassif2, Steven L Barnett2.   

Abstract

BACKGROUND: For establishing femoral component position, gap-balancing (GB) and measured resection (MR) techniques were compared using a force sensor.
METHODS: Ninety-one patients were randomized to undergo primary total knee arthroplasty using either MR (n = 43) or GB (n = 48) technique using a single total knee arthroplasty design. GB was performed with an instrumented tensioner. Force sensor data were obtained before the final implantation.
RESULTS: GB resulted in greater range of femoral component rotation vs MR (1.5° ± 2.9° vs 3.1° ± 0.5°, P < .05) and posterior condylar cut thickness medially (10.2 ± 2.0 mm vs 9.0 ± 1.3 mm) and laterally (8.5 ± 1.9 mm vs 6.4 ± 1.0 mm). Force sensor data showed a decreased intercompartmental force difference at full flexion in GB (.8 ± 2.3 vs 2.0 ± 3.3u, 1u ≈ 15 N, P < .05).
CONCLUSION: GB resulted in a greater range of femoral component rotation and thicker posterior condylar cuts resulting in an increased flexion space relative to MR. Intercompartmental force difference trended toward a more uniform distribution between full extension and full flexion in the GB vs MR group.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  FuZion balancer; TEA; TKA; eLIBRA sensor; gap balancing; measured resection

Mesh:

Year:  2018        PMID: 29602537     DOI: 10.1016/j.arth.2018.02.044

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

1.  Intra- and postoperative assessment of femoral component rotation in total knee arthroplasty: an EKA knee expert group clinical review.

Authors:  Paweł Skowronek; Markus Arnold; Christian Starke; Agnieszka Bartyzel; Lukas B Moser; Michael T Hirschmann
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-30       Impact factor: 4.342

2.  Gap balancing versus measured resection for primary total knee arthroplasty: a meta-analysis study.

Authors:  Filippo Migliorini; Jörg Eschweiler; Yasser El Mansy; Valentin Quack; Hanno Schenker; Markus Tingart; Arne Driessen
Journal:  Arch Orthop Trauma Surg       Date:  2020-05-14       Impact factor: 3.067

3.  High accuracy of a new robotically assisted technique for total knee arthroplasty: an in vivo study.

Authors:  Stefano Marco Paolo Rossi; Rudy Sangaletti; Loris Perticarini; Flavio Terragnoli; Francesco Benazzo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2022-01-04       Impact factor: 4.342

4.  Relationship between surgical balancing and outcome measures in total knees.

Authors:  Lauren M Chu; Patrick A Meere; Cheongeun Oh; Peter S Walker
Journal:  Arthroplast Today       Date:  2019-03-02

5.  Gap balancing improve squat function and knee function: a randomized controlled trial comparing gap balancing and measured resection.

Authors:  Qingfang Xiao; Bo Liu; Binghao Zhao
Journal:  J Orthop Surg Res       Date:  2021-04-08       Impact factor: 2.359

6.  Spacer-based gap balancing is useful in total knee arthroplasty: a 3-year follow-up of a retrospective study.

Authors:  Yanhui Hu; Da Song; Yi Liu; Yong Zhao; Wenpu Ma; Yiqun Yang; Zhenfeng Yuan
Journal:  J Orthop Surg Res       Date:  2021-10-21       Impact factor: 2.359

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.