False lumen intervention to promote remodelling and thrombosis-The FLIRT concept in aortic dissection.

Xun Yuan1,2, Andreas Mitsis1, Thomas Semple3, Mireya Castro Verdes1, Esther Cambronero-Cortinas1, Yida Tang2, Christoph A Nienaber1.   

Abstract

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) has changed the management of aortic dissection by induced remodelling. Beyond reconstructing the true lumen, we describe the concept of False Lumen Intervention to promote Remodelling and Thrombosis (FLIRT) in both type A and B aortic dissection.
METHODS: Between 2011 and 2017, 10 patients with aortic dissection (5 type A; 5 type B) underwent FLIRT using a combination of patent foramen ovale (PFO) or atrial septal defect (ASD) occluders, coils and glue. Patients were followed by computed tomography (CT) angiogram prior to, and 6 months following, discharge to evaluate false lumen (FL) thrombosis and aortic remodelling. Outcomes analyzed comprised successful device delivery, completeness of FL thrombosis and aortic remodelling, procedure related complications and mortality.
RESULTS: FLIRT induced aortic remodelling in all cases of proximal dissection, with aortic shrinkage from 63.8 ± 7.5 pre-FLIRT, to 50.2 ± 6.6 mm (P = 0.057) and an increase in true lumen area from 5.8 ± 3.6 to 11.4 ± 2.5 cm2 (P = 0.006). In distal dissection (after previous TEVAR with residual FL flow), FLIRT successfully induced FL thrombosis in 4 of 5 cases at first attempt (1 case required additional coiling of the gutter between left subclavian artery and stent-graft for complete thrombosis). While maximal aortic diameter remained unchanged (55.6 ± 9.1 pre-FLIRT and 54.4 ± 13.7 mm at follow-up), true lumen area increased from 7.8 ± 2.3 pre-procedure, to 10.6 ± 1.5 cm2 at follow-up (P = 0.016), consistent with remodelling.
CONCLUSION: Interventional FL management, using the FLIRT concept, is feasible in selected cases of aortic dissection, promotes FL thrombosis and induces successful remodelling.
© 2018 Wiley Periodicals, Inc.

Entities:  

Keywords:  coils; false lumen; occluder devices; remodeling; thoracic endovascular aortic repair; vascular plug

Mesh:

Year:  2018        PMID: 29602262     DOI: 10.1002/ccd.27599

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  8 in total

1.  Chronic thoracoabdominal aortic dissection: endovascular options to obliterate the false lumen.

Authors:  Patrick R Vargo; Jean-Luc Maigrot; Eric E Roselli
Journal:  Ann Cardiothorac Surg       Date:  2021-11

2.  Transesophageal Ultrasound Guidance for Endovascular Interventions on the Aorta.

Authors:  Mireya Castro-Verdes; Xun Yuan; Andreas Mitsis; Wei Li; Christoph A Nienaber
Journal:  Aorta (Stamford)       Date:  2022-05-31

3.  Aortic intervention guided by contrast-enhanced transoesophageal ultrasound whist waiting for cardiac transplantation: a case report.

Authors:  Mireya Castro Verdes; Xun Yuan; Wei Li; Roxy Senior; Christoph A Nienaber
Journal:  Eur Heart J Case Rep       Date:  2020-12-12

4.  A Novel Solution for Distal Dilation of Chronic Dissection After Repair Involving Visceral Branches: The Road Block Strategy.

Authors:  Yiming Li; Zhenjiang Li; Jiaxuan Feng; Rui Feng; Jian Zhou; Zaiping Jing
Journal:  Front Cardiovasc Med       Date:  2022-03-09

5.  Long-Term Aortic Remodeling After Thoracic Endovascular Aortic Repair of Acute, Subacute, and Chronic Type B Dissections.

Authors:  Zhenjiang Li; Xiaohui Wang; Yangyan He; Yilang Xiang; Ziheng Wu; Hongkun Zhang; Donglin Li
Journal:  Front Cardiovasc Med       Date:  2022-03-30

6.  The role of peripheral blood eosinophil counts in acute Stanford type A aortic dissection patients.

Authors:  Xichun Qin; Yaxuan Gao; Yi Jiang; Feng Zhu; Wei Xie; Xinlong Tang; Yunxing Xue; Dongjin Wang; Hailong Cao
Journal:  Front Surg       Date:  2022-08-30

Review 7.  TEVAR and EVAR, the unknown knowns of the cardiovascular hemodynamics; and the immediate and long-term consequences of fabric material on major adverse clinical outcome.

Authors:  Sherif Sultan; Yogesh Acharya; Osama Soliman; Juan Carlos Parodi; Niamh Hynes
Journal:  Front Surg       Date:  2022-08-30

8.  The characteristics of distal tears affect false lumen thrombosis rate after thoracic endovascular aortic repair for acute type B dissection.

Authors:  Da Li; Ding Yuan; Liqing Peng; Tinghui Zheng; Yubo Fan
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-10-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.