Literature DB >> 29599034

Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up.

Seung-Jae Lim1, Hyung-Gon Ryu2, Hyeon-Jun Eun1, Chan-Woo Park1, Kyeu-Back Kwon1, Youn-Soo Park1.   

Abstract

BACKGROUND: The purpose of this study is to evaluate the minimum 5-year outcomes and bearing-specific complications in a single surgeon series of fourth-generation alumina ceramic-on-ceramic total hip arthroplasties (THAs).
METHODS: We retrospectively analyzed 667 patients (749 hips) who underwent primary THAs by a single surgeon using fourth-generation alumina ceramic bearings. There were 315 men and 352 women with a mean age of 54.2 years. The surgeon used cementless prostheses with an identical design and BIOLOX Delta ceramics in all hips, using a 36-mm head in 472 hips (63%) and a 32-mm head in 227. The mean follow-up duration was 6.5 years (range, 5 to 8 years).
RESULTS: The mean Harris hip score improved from 45.6 points preoperatively to 91.3 points at final follow-up. All but 1 acetabular cup and all femoral stems were well fixed. No radiographic evidence of osteolysis was identified at final follow-up. There were 2 (0.3%) ceramic liner fractures and no ceramic head fractures. A total of 48 hips (6.4%) exhibited audible noise (29 clickings and 19 squeakings), but no patient required revision. Other complications were 1 dislocation, 1 deep infection, 3 iliopsoas tendonitis, and 6 periprosthetic femoral fractures. Kaplan-Meier survivorship for revision for any reason was 98.6% (95% confidence interval, 97.7-99.5) at 6.5 years.
CONCLUSION: Delta ceramic-on-ceramic THAs had a high rate of survivorship without radiographic evidence of osteolysis at 6.5-year follow-up. However, we found 0.3% ceramic liner fractures and 6.4% audible noises associated with the use of Delta ceramics.
Copyright © 2018 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  bearing; ceramic; complications; outcome; total hip arthroplasty

Mesh:

Substances:

Year:  2018        PMID: 29599034     DOI: 10.1016/j.arth.2018.02.045

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  10 in total

1.  Preventing ceramic liner fracture after Delta ceramic-on-ceramic total hip arthroplasty.

Authors:  Young-Kyun Lee; Jae-Young Lim; Yong-Chan Ha; Tae-Young Kim; Woon-Hwa Jung; Kyung-Hoi Koo
Journal:  Arch Orthop Trauma Surg       Date:  2020-06-12       Impact factor: 3.067

2.  Third generation delta ceramic-on-ceramic bearing for total hip arthroplasty at mid-term follow-up.

Authors:  Alessandro Bistolfi; Riccardo Ferracini; Alessandro Aprato; Alessandro Massè; Walter Daghino; Sara Lea; Stefano Artiaco; Gwo-Chin Lee
Journal:  J Orthop       Date:  2020-08-28

3.  Projections and Epidemiology of Revision Hip and Knee Arthroplasty in the United States to 2030.

Authors:  Andrew M Schwartz; Kevin X Farley; George N Guild; Thomas L Bradbury
Journal:  J Arthroplasty       Date:  2020-02-19       Impact factor: 4.757

4.  Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty.

Authors:  Edward T Davis; Ville Remes; Petri Virolainen; Peter Gebuhr; Bart Van Backlé; Matthew P Revell; Branko Kopjar
Journal:  J Orthop Surg Res       Date:  2021-01-09       Impact factor: 2.359

5.  Fourth-Generation Ceramic-on-Ceramic THA in Patients with Ankylosing Spondylitis: A Minimum 10-Year Follow-Up.

Authors:  Liangliang Li; Jun Fu; Chi Xu; Ming Ni; Wei Chai; Libo Hao; Yonggang Zhou; Jiying Chen
Journal:  Orthop Surg       Date:  2022-04-18       Impact factor: 2.279

6.  Squeaking Is Common and Increases Over Time Among Patients With Long-term Follow-up After Ceramic-on-ceramic THA.

Authors:  Kevin Taniguchi; Michael Quacinella; Brian Barlow
Journal:  Clin Orthop Relat Res       Date:  2021-04-01       Impact factor: 4.176

7.  Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?: A retrospective study.

Authors:  Yuan Luo; Xue-Feng Sun; Jin Chen; Wei Cui; Tao Wang
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

8.  Ceramic Liner Fracture Caused by an Impingement between the Stem Shoulder and the Ceramic Liner.

Authors:  Sunhyung Lee; Seung Won Jeon; Jeong Joon Yoo; Hee Joong Kim
Journal:  Hip Pelvis       Date:  2020-09-02

9.  The reasons for ceramic-on-ceramic revisions between the third- and fourth-generation bearings in total hip arthroplasty from multicentric registry data.

Authors:  Sang-Min Kim; Kee Hyung Rhyu; Jeong Joon Yoo; Seung-Jae Lim; Je Hyun Yoo; Suc Hyun Kweon; Kyung-Jae Lee; Seung-Beom Han
Journal:  Sci Rep       Date:  2021-03-10       Impact factor: 4.379

10.  Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty.

Authors:  Thomas J Blumenfeld; Joel Politi; Sean Coker; Tammy O'Dell; William Hamilton
Journal:  Arthroplast Today       Date:  2022-01-18
  10 in total