Literature DB >> 29597176

Effect of disinfectant residual on the interaction between bacterial growth and assimilable organic carbon in a drinking water distribution system.

Weiying Li1, Junpeng Zhang2, Feng Wang2, Lin Qian2, Yanyan Zhou2, Wanqi Qi2, Jiping Chen2.   

Abstract

Public health is threatened by deteriorated water quality due to bacterial regrowth and uncontrolled growth-related problems in drinking water distribution systems (DWDSs). To investigate the scope of this problem, a two-year field study was conducted in south China. The amount of assimilable organic carbon (AOC), total cell concentrations (TCC), and intact cell concentrations (ICC) of water samples were determined by flow cytometry. The results indicated that ICC was significantly correlated to AOC concentration when the chlorine concentration was less than 0.15 mg/L, and ICC was lower at chlorine concentrations greater than 0.15 mg/L, suggesting that free chlorine level had effect on AOC and ICC. To further analyze the effect of disinfectant on AOC and bacterial growth, we designed an orthogonal experiment with different dosages of two commonly used disinfectants, chlorine and chloramine. The results demonstrated that high concentrations of free chlorine (>0.15 mg/L) and chloramine (>0.4 mg/L) were associated with relatively low proportions of intact cells and cultivable bacteria. Compared with chlorine, chloramine tended to cause lower AOC level and intact cells, likely because the chlorinated disinfection byproducts (DBPs) were more easily absorbed by bacteria than the chloraminated DBPs. Based on the statistical analysis of 240 water samples, ICC was limited when AOC concentration was less than 135 μg/L, while temperature and the number of small-size particles showed positive effects on ICC (P<0.05). We conclude that the use of chloramine and controlling particle numbers should be suitable strategies to limit bacterial regrowth.
Copyright © 2018 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Assimilable organic carbon (AOC); Biological stability; Disinfectant effect; Drinking water distribution system; Intact cell concentrations (ICC)

Mesh:

Substances:

Year:  2018        PMID: 29597176     DOI: 10.1016/j.chemosphere.2018.03.056

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  5 in total

Review 1.  The role of biofilm in the development and dissemination of ubiquitous pathogens in drinking water distribution systems: an overview of surveillance, outbreaks, and prevention.

Authors:  Bahaa A Hemdan; Gamila E El-Taweel; Pranab Goswami; Deepak Pant; Surajbhan Sevda
Journal:  World J Microbiol Biotechnol       Date:  2021-01-28       Impact factor: 3.312

2.  Water quality characteristics and corrosion potential in blending zones in X city drinking water distribution system.

Authors:  Hui Zhang; Kai Wang; Xue Zhou; Weihuang Zhu; Wendong Wang
Journal:  Environ Monit Assess       Date:  2018-08-16       Impact factor: 2.513

3.  Fabrication of a Nickel Ferrite/Nanocellulose-Based Nanocomposite as an Active Sensing Material for the Detection of Chlorine Gas.

Authors:  Nurjahirah Janudin; Noor Azilah Mohd Kasim; Victor Feizal Knight; Mohd Nor Faiz Norrrahim; Mas Amira Idayu Abdul Razak; Norhana Abdul Halim; Siti Aminah Mohd Noor; Keat Khim Ong; Mohd Hanif Yaacob; Muhammad Zamharir Ahmad; Wan Md Zin Wan Yunus
Journal:  Polymers (Basel)       Date:  2022-05-06       Impact factor: 4.967

4.  Optimizing disinfectant residual dosage in engineered water systems to minimize the overall health risks of opportunistic pathogens and disinfection by-products.

Authors:  Chiqian Zhang; Jingrang Lu
Journal:  Sci Total Environ       Date:  2021-01-23       Impact factor: 7.963

5.  Biofilm Microbiome (Re)Growth Dynamics in Drinking Water Distribution Systems Are Impacted by Chlorine Concentration.

Authors:  Katherine E Fish; Joby B Boxall
Journal:  Front Microbiol       Date:  2018-10-23       Impact factor: 5.640

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.