| Literature DB >> 29595881 |
Troy J Cross1,2, Courtney Wheatley1, Glenn M Stewart1,2, Kirsten Coffman1, Alex Carlson1, Jan Stepanek3, Norman R Morris2,4, Bruce D Johnson1.
Abstract
The purpose of this report was to illustrate how thoracic gas compression (TGC) artifact, and differences in air density, may together conflate the interpretation of changes in the forced expiratory flows (FEFs) at high altitude (>2400 m). Twenty-four adults (10 women; 44 ± 15 year) with normal baseline pulmonary function (>90% predicted) completed a 12-day sojourn at Mt. Kilimanjaro. Participants were assessed at Moshi (Day 0, 853 m) and at Barafu Camp (Day 9, 4837 m). Typical maximal expiratory flow-volume (MEFV) curves were obtained in accordance with ATS/ERS guidelines, and were either: (1) left unadjusted; (2) adjusted for TGC by constructing a "maximal perimeter" MEFV curve; or (3) adjusted for both TGC and differences in air density between altitudes. Forced vital capacity (FVC) was lower at Barafu compared with Moshi camp (5.19 ± 1.29 L vs. 5.40 ± 1.45 L, P < 0.05). Unadjusted data indicated no difference in the mid-expiratory flows (FEF25-75% ) between altitudes (∆ + 0.03 ± 0.53 L sec-1 ; ∆ + 1.2 ± 11.9%). Conversely, TGC-adjusted data revealed that FEF25-75% was significantly improved by sojourning at high altitude (∆ + 0.58 ± 0.78 L sec-1 ; ∆ + 12.9 ± 16.5%, P < 0.05). Finally, when data were adjusted for TGC and air density, FEFs were "less than expected" due to the lower air density at Barafu compared with Moshi camp (∆-0.54 ± 0.68 L sec-1 ; ∆-10.9 ± 13.0%, P < 0.05), indicating a mild obstructive defect had developed on ascent to high altitude. These findings clearly demonstrate the influence that TGC artifact, and differences in air density, bear on flow-volume data; consequently, it is imperative that future investigators adjust for, or at least acknowledge, these confounding factors when comparing FEFs between altitudes.Entities:
Keywords: Airflow density dependence; forced expiratory flows; high altitude; thoracic gas compression
Mesh:
Year: 2018 PMID: 29595881 PMCID: PMC5875542 DOI: 10.14814/phy2.13576
Source DB: PubMed Journal: Physiol Rep ISSN: 2051-817X
Figure 1Elevation profile during Mt. Kilimanjaro expedition. The closed circles represent the elevation above sea level, whereas the open circles denote the barometric pressure (P b) throughout the 12‐day expedition. The vertical dotted lines indicate the days where pulmonary function data were recorded at Moshi and Barafu camp.
Impact of thoracic gas compression (TGC) and air‐density dependence (DD) on pulmonary function at Moshi and Barafu camps on Mt. Kilimanjaro
| Adjustment | Moshi (853 m) | Barafu (4837 m) | |||
|---|---|---|---|---|---|
| Unadjusted | TGC | Unadjusted | TGC | TGC+DD | |
| Dynamic volumes | |||||
| FVC (L) | 5.40 ± 1.45 | – | 5.19 ± 1.29 | – | – |
| FVC (% pred.) | 114 ± 21 | – | 110 ± 18 | – | – |
| FEV1,comp (L) | 4.07 ± 0.97 | 4.18 ± 1.01 | 4.01 ± 0.96 | 4.25 ± 1.05 | 3.89 ± 0.97 |
| FEV1,comp (% pred.) | 109 ± 16 | 112 ± 16 | 107 ± 16 | 113 ± 16 | 104 ± 15 |
| FEV1,comp/FVC (%) | 76 ± 7 | 78 ± 7 | 78 ± 6 | 82 ± 6 | 75 ± 7 |
| FEV1,comp/FVC (% pred.) | 96 ± 9 | 98 ± 9 | 98 ± 9 | 103 ± 8 | 94 ± 9 |
| Forced expiratory flows | |||||
| PEFR (L sec−1) | 9.16 ± 2.07 | 9.30 ± 2.02 | 9.51 ± 2.26 | 9.57 ± 2.22 | 7.55 ± 1.65 |
| PEFR (%pred.) | 104 ± 16 | 106 ± 15 | 108 ± 16 | 109 ± 16 | 86 ± 13 |
| FEF25–75% (L sec−1) | 4.53 ± 1.23 | 4.70 ± 1.25 | 4.55 ± 1.24 | 5.28 ± 1.45 | 4.16 ± 1.14 |
| FEF25–75% (% pred.) | 132 ± 35 | 137 ± 35 | 132 ± 35 | 153 ± 39 | 121 ± 31 |
| FEF25% (L sec−1) | 7.35 ± 1.88 | 7.51 ± 1.97 | 7.52 ± 1.85 | 8.07 ± 1.84 | 6.37 ± 1.45 |
| FEF50% (L sec−1) | 4.55 ± 1.36 | 4.67 ± 1.32 | 4.56 ± 1.56 | 5.32 ± 1.78 | 4.20 ± 1.40 |
| FEF75% (L sec−1) | 1.77 ± 0.58 | 2.06 ± 0.71 | 1.66 ± 0.54 | 2.22 ± 0.74 | 1.75 ± 0.59 |
| Aex (L2 sec−1) | 431 ± 99 | 446 ± 103 | 439 ± 104 | 485 ± 117 | 382 ± 93 |
Values represent means ± SD. TGC+DD, density‐dependence adjustment performed on TGC‐adjusted data; FVC, forced vital capacity; FEV1,comp, computed forced expiratory volume in 1 sec; PEFR, peak expiratory flow rate; FEF25–75%, mid‐expiratory flows; FEF25%, FEF50%, and FEF75%, forced expiratory flows at 25%, 50% and 75% of FVC; Aex, area under maximal expiratory flow‐volume curve. TGC, thoracic gas compression; DD, air‐density dependence
Significantly different from unadjusted value at the corresponding elevation, P < 0.05.
Significantly different from TGC‐adjusted value at the corresponding elevation, P < 0.05.
Figure 2Group‐averaged maximal expiratory flow‐volume curves before and after adjustment for TGC artifact. The lower inner curves in the top panels represent the unadjusted flow‐volume data, whereas the outer curves denote flow‐volume data obtained from the maximal “perimeter” curve (i.e., TGC adjusted data). The stippled area between these two curves indicates the magnitude of TGC artifact. The lower panels illustrate the absolute difference in instantaneous forced expiratory flows between unadjusted and TGC adjusted datasets. Standard deviations are omitted from this figure for clarity. TGC, thoracic gas compression.
Figure 3The absolute (left panel) and relative (right panel) magnitudes of TGC artifact at Moshi and Barafu camp on Mt. Kilimanjaro. Data are presented as mean ± SD. PEFR, peak expiratory flow rate; FEF 25%, FEF 50%, and FEF 75%, forced expiratory flows at 25%, 50%, and 75% of forced vital capacity. *Significant difference between elevations (i.e., Moshi vs. Barafu camp) for corresponding forced expiratory flow, P < 0.05. Note that a larger negative value indicates a greater degree of underestimation in the corresponding forced expiratory flow due to TGC artifact. TGC, thoracic gas compression.
Changes in pulmonary function during ascent from Moshi to Barafu camp on Mt. Kilimanjaro
| Adjustment | Absolute (∆) | Relative (∆%) | ||||
|---|---|---|---|---|---|---|
| Unadjusted | TGC | TGC + DD | Unadjusted | TGC | TGC + DD | |
| Dynamic volumes | ||||||
| FVC (L) | −0.21 ± 0.33 | – | – | −3.2 ± 5.3 | – | – |
| FEV1,comp (L) | −0.06 ± 0.16 | 0.07 ± 0.33 | −0.29 ± 0.33 | −1.3 ± 4.0 | 1.8 ± 7.0 | −7.0 ± 6.7 |
| FEV1,comp/FVC (%) | 1 ± 3 | 4 ± 5 | −3 ± 5 | 0.2 ± 0.6 | 0.6 ± 0.8 | −4.1 ± 6.4 |
| Forced expiratory flows | ||||||
| PEFR (L·sec−1) | 0.35 ± 0.83 | 0.27 ± 0.93 | −1.75 ± 0.85 | 4.1 ± 8.4 | 3.1 ± 10.0 | −18.6 ± 7.9 |
| FEF25‐75% (L·sec−1) | 0.03 ± 0.53 | 0.58 ± 0.78 | −0.54 ± 0.68 | 1.2 ± 11.9 | 12.9 ± 16.5 | −10.9 ± 13.0 |
| FEF25% (L·sec−1) | 0.17 ± 0.78 | 0.56 ± 0.92 | −1.14 ± 0.96 | 3.0 ± 10.2 | 8.9 ± 13.7 | −14.1 ± 10.8 |
| FEF50% (L·sec−1) | 0.02 ± 0.77 | 0.66 ± 1.02 | −0.46 ± 0.81 | 0.6 ± 14.7 | 14.3 ± 20.9 | −9.8 ± 16.5 |
| FEF75% (L·sec−1) | −0.10 ± 0.26 | 0.16 ± 0.60 | −0.31 ± 0.55 | −5.0 ± 14.4 | 11.2 ± 31.2 | −12.3 ± 24.7 |
| Aex (L2·sec−1) | 8 ± 37 | 38 ± 54 | −64 ± 47 | 2.1 ± 7.7 | 8.6 ± 11.6 | −14.3 ± 9.2 |
Values represent means ± SD.
TGC, thoracic gas compression; TGC + DD, density‐dependence adjustment performed on TGC‐adjusted data; FVC, forced vital capacity; FEV1,comp, computed forced expiratory volume in 1 sec; PEFR, peak expiratory flow rate; FEF25–75%, mid‐expiratory flows; FEF25%, FEF50%, and FEF75%, forced expiratory flows at 25%, 50%, and 75% of FVC; Aex, area under maximal expiratory flow‐volume curve.
Significantly different from unadjusted value at the corresponding elevation, P < 0.05.
Significantly different from TGC‐adjusted value at the corresponding elevation, P < 0.05.
Significantly different from zero, P < 0.05.
Figure 4The influence of adjusting for TGC artifact and DD on the interpretation of changes in forced expiratory flows while sojourning at high altitude. Data are presented as mean ± SD for instantaneous forced expiratory flows at 25%, 50%, and 75% of forced vital capacity. TGC + DD: maximal expiratory flow‐volume data adjusted for both TGC and DD; FVC: forced vital capacity. *Significant difference between elevations (i.e., Moshi vs. Barafu camp) for corresponding forced expiratory flow, P < 0.05. The dataset shown in the left panel illustrates the FEFs “as collected” at both elevations (i.e., no adjustments). The dataset in the middle panel reveals that once FEFs are adjusted for TGC artifact, the maximal expiratory flow‐volume curve is, on average, higher at Barafu (high altitude) compared with Moshi (low altitude) – particularly over the first 60% of the forced expiratory volume. The dataset in the right panel (TGC + DD) indicates that while FEFs were physically higher at Barafu, they were not as high as expected given the differences in air density between altitudes. Said differently, the TGC + DD dataset at Barafu camp (thickened line) depicts what would be expected if our participants performed their forced expiratory efforts while breathing an inspirate of equal density to that at Moshi. Consequently, the TGC + DD dataset indicates that our participants may have experienced a mild obstructive change in pulmonary function by sojourning at high altitude. TGC, thoracic gas compression; DD, air‐density dependence.