Literature DB >> 29595150

Spiraling contaminant electrons increase doses to surfaces outside the photon beam of an MRI-linac with a perpendicular magnetic field.

S L Hackett1, B van Asselen, J W H Wolthaus, J J Bluemink, K Ishakoglu, J Kok, J J W Lagendijk, B W Raaymakers.   

Abstract

The transverse magnetic field of an MRI-linac sweeps contaminant electrons away from the radiation beam. Films oriented perpendicular to the magnetic field and 5 cm from the radiation beam edge show a projection of the divergent beam, indicating that contaminant electrons spiral along magnetic field lines and deposit dose on surfaces outside the primary beam perpendicular to the magnetic field. These spiraling contaminant electrons (SCE) could increase skin doses to protruding regions of the patient along the cranio-caudal axis. This study investigated doses from SCE for an MRI-linac comprising a 7 MV linac and a 1.5 T MRI scanner. Surface doses to films perpendicular to the magnetic field and 5 cm from the radiation beam edge showed increased dose within the projection of the primary beam, whereas films parallel to the magnetic field and 5 cm from the beam edge showed no region of increased dose. However, the dose from contaminant electrons is absorbed within a few millimeters. For large fields, the SCE dose is within the same order of magnitude as doses from scattered and leakage photons. Doses for both SCE and scattered photons decrease rapidly with decreasing beam size and increasing distance from the beam edge.

Entities:  

Mesh:

Year:  2018        PMID: 29595150     DOI: 10.1088/1361-6560/aaba8f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  10 in total

1.  Comparison of treatment plans for a high-field MRI-linac and a conventional linac for esophageal cancer.

Authors:  Marcel Nachbar; David Mönnich; Paul Kalwa; Daniel Zips; Daniela Thorwarth; Cihan Gani
Journal:  Strahlenther Onkol       Date:  2018-10-25       Impact factor: 3.621

2.  Sources of out-of-field dose in MRgRT: an inter-comparison of measured and Monaco treatment planning system doses for the Elekta Unity MR-linac.

Authors:  John Baines; Marcus Powers; Glen Newman
Journal:  Phys Eng Sci Med       Date:  2021-08-10

3.  Electron streams in air during magnetic-resonance image-guided radiation therapy.

Authors:  Hyun Joon An; Jung-In Kim; Jong Min Park
Journal:  PLoS One       Date:  2019-05-15       Impact factor: 3.240

4.  In-Air Electron Streaming Effect for Esophageal Cancer Radiotherapy With a 1.5 T Perpendicular Magnetic Field: A Treatment Planning Study.

Authors:  Hongdong Liu; Shouliang Ding; Bin Wang; Yongbao Li; Ying Sun; Xiaoyan Huang
Journal:  Front Oncol       Date:  2020-12-01       Impact factor: 6.244

5.  Analysis of the electron-stream effect in patients treated with partial breast irradiation using the 1.5 T MR-linear accelerator.

Authors:  C De-Colle; M Nachbar; D Mӧnnich; S Boeke; C Gani; N Weidner; V Heinrich; J Winter; S Tsitsekidis; O Dohm; D Zips; D Thorwarth
Journal:  Clin Transl Radiat Oncol       Date:  2021-01-22

6.  Commissioning measurements on an Elekta Unity MR-Linac.

Authors:  Marcus Powers; John Baines; Robert Crane; Chantelle Fisher; Stephen Gibson; Linda Marsh; Bronwyn Oar; Ariadne Shoobridge; Emily Simpson-Page; Marchant Van der Walt; Glenn de Vine
Journal:  Phys Eng Sci Med       Date:  2022-03-02

7.  Comparison of Prospectively Generated Glioma Treatment Plans Clinically Delivered on Magnetic Resonance Imaging (MRI)-Linear Accelerator (MR-Linac) Versus Conventional Linac: Predicted and Measured Skin Dose.

Authors:  Michael H Wang; Anthony Kim; Mark Ruschin; Hendrick Tan; Hany Soliman; Sten Myrehaug; Jay Detsky; Zain Husain; Eshetu G Atenafu; Brian Keller; Arjun Sahgal; Chia-Lin Tseng
Journal:  Technol Cancer Res Treat       Date:  2022 Jan-Dec

8.  Automatic 3D Monte-Carlo-based secondary dose calculation for online verification of 1.5 T magnetic resonance imaging guided radiotherapy.

Authors:  Marcel Nachbar; David Mönnich; Oliver Dohm; Melissa Friedlein; Daniel Zips; Daniela Thorwarth
Journal:  Phys Imaging Radiat Oncol       Date:  2021-06-21

9.  Monte Carlo simulations of out-of-field skin dose due to spiralling contaminant electrons in a perpendicular magnetic field.

Authors:  Victor N Malkov; Sara L Hackett; Bram van Asselen; Bas W Raaymakers; Jochem W H Wolthaus
Journal:  Med Phys       Date:  2019-02-14       Impact factor: 4.071

10.  Characterizing magnetically focused contamination electrons by off-axis irradiation on an inline MRI-Linac.

Authors:  Elizabeth Patterson; Bradley M Oborn; Dean Cutajar; Urszula Jelen; Gary Liney; Anatoly B Rosenfeld; Peter E Metcalfe
Journal:  J Appl Clin Med Phys       Date:  2022-03-25       Impact factor: 2.243

  10 in total