Abstract

This research describes a nanowire network-based method for detecting the activity of myeloperoxidase (MPO), a biomarker of acute coronary syndromes (ACS). Trimetallic CuPdPt nanowire networks (CuPdPt NWNWs) were prepared by a one-step chemical reduction method. The metallic precursors quickly form nanowire network structures without the need for additional capping agents or surfactants. This process creates a product with a clean surface. The NWNWs were dropped onto a glassy carbon electrode (GCE) to obtain a sensor with good catalytic activity towards the reduction of hydrogen peroxide (H2O2), which was used as an electrochemical probe working at -0.4 V (vs. SCE). It also provided a large surface for further modification. Next, an antibody against MPO was immobilized on the modified GCE via the stable conjunction between Cu, Pt, Pd and amino groups. Upon binding of MPO to the antibody on the GCE, the current response to H2O2 was reduced by 35 μA·cm-2. The immunosensor had a linear response within the 100 fg·mL-1 to 50 ng·mL-1 MPO concentration range and a 33 fg·mL-1 detection limit (at an S/N ratio of 3). The recovery of spiked serum samples ranged from 99.8 to 103.6%. This result suggests that the method can be applied to the quantitation of MPO in human serum samples. Graphical abstract A trimetallic CuPdPt nanowire networks was placed on a glassy cabon electrode (GCE) to design an immunosensor for myeloperoxidase (MPO), a biomarker for the acute coronary syndrome (ACS). Antibody against MPO was immobilized on the network via conjugation between Cu, Pt, Pd and amino groups. Amperometric i-t measurements were conducted to quantify the amount of MPO that binds to the antibody on the surface of the modified GCE.

Entities:  

Keywords:  Amperometry; Catalytic activity; Electrochemical immunosensor; Myeloperoxidase; Network-based platform; One-step method

Mesh:

Substances:

Year:  2017        PMID: 29594375     DOI: 10.1007/s00604-017-2563-y

Source DB:  PubMed          Journal:  Mikrochim Acta        ISSN: 0026-3672            Impact factor:   5.833


  32 in total

1.  Use of Triton X-114 as a weak capping agent for one-pot aqueous phase synthesis of ultrathin noble metal nanowires and a primary study of their electrocatalytic activity.

Authors:  Rui Liu; Jing-Fu Liu; Gui-Bin Jiang
Journal:  Chem Commun (Camb)       Date:  2010-08-23       Impact factor: 6.222

2.  Development of nanostructured biomedical micro-drug testing device based on in situ cellular activity monitoring.

Authors:  Shalini Prasad; Jorge Quijano
Journal:  Biosens Bioelectron       Date:  2005-06-28       Impact factor: 10.618

3.  Ultrasensitive immunosensor for cancer biomarker proteins using gold nanoparticle film electrodes and multienzyme-particle amplification.

Authors:  Vigneshwaran Mani; Bhaskara V Chikkaveeraiah; Vyomesh Patel; J Silvio Gutkind; James F Rusling
Journal:  ACS Nano       Date:  2009-03-24       Impact factor: 15.881

Review 4.  Myeloperoxidase and cardiovascular disease.

Authors:  Stephen J Nicholls; Stanley L Hazen
Journal:  Arterioscler Thromb Vasc Biol       Date:  2005-03-24       Impact factor: 8.311

5.  Electronic control of chemistry and catalysis at the surface of an individual tin oxide nanowire.

Authors:  Y Zhang; A Kolmakov; Y Lilach; M Moskovits
Journal:  J Phys Chem B       Date:  2005-02-10       Impact factor: 2.991

6.  Platelet function predicts myocardial damage in patients with acute myocardial infarction.

Authors:  Martin Frossard; Ingrid Fuchs; Judith M Leitner; Kety Hsieh; Marianne Vlcek; Heidrun Losert; Hans Domanovits; Wolfgang Schreiber; Anton N Laggner; Bernd Jilma
Journal:  Circulation       Date:  2004-08-16       Impact factor: 29.690

7.  Iridium oxide nanomonitors: clinical diagnostic devices for health monitoring systems.

Authors:  Vinu L Venkatraman; Ravikiran K Reddy; Fengyang Zhang; David Evans; Bruce Ulrich; Shalini Prasad
Journal:  Biosens Bioelectron       Date:  2009-04-01       Impact factor: 10.618

8.  Increased myeloperoxidase in the placenta and circulation of women with preeclampsia.

Authors:  Robin E Gandley; Jennifer Rohland; Yan Zhou; Eiji Shibata; Gail F Harger; Augustine Rajakumar; Valerian E Kagan; Nina Markovic; Carl A Hubel
Journal:  Hypertension       Date:  2008-06-30       Impact factor: 10.190

9.  Ultrasensitive electrochemical immunoassay for squamous cell carcinoma antigen using dumbbell-like Pt-Fe₃O₄ nanoparticles as signal amplification.

Authors:  Dan Wu; Haixia Fan; Yuyang Li; Yong Zhang; Huixin Liang; Qin Wei
Journal:  Biosens Bioelectron       Date:  2013-02-26       Impact factor: 10.618

10.  Synthesis and characterization of 9 nm Pt-Ni octahedra with a record high activity of 3.3 A/mg(Pt) for the oxygen reduction reaction.

Authors:  Sang-Il Choi; Shuifen Xie; Minhua Shao; Jonathan H Odell; Ning Lu; Hsin-Chieh Peng; Lesia Protsailo; Sandra Guerrero; Jinho Park; Xiaohu Xia; Jinguo Wang; Moon J Kim; Younan Xia
Journal:  Nano Lett       Date:  2013-06-24       Impact factor: 11.189

View more
  2 in total

1.  Amperometric sandwich immunoassay for determination of myeloperoxidase by using gold nanoparticles encapsulated in graphitized mesoporous carbon.

Authors:  Bei Liu; Lingsong Lu
Journal:  Mikrochim Acta       Date:  2019-03-30       Impact factor: 5.833

2.  A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor.

Authors:  Sopit Phetsang; Duangruedee Khwannimit; Parawee Rattanakit; Narong Chanlek; Pinit Kidkhunthod; Pitchaya Mungkornasawakul; Jaroon Jakmunee; Kontad Ounnunkad
Journal:  Front Chem       Date:  2021-05-20       Impact factor: 5.221

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.