Literature DB >> 2959394

Validation of Doppler-derived pulmonary arterial pressure in patients with ductus arteriosus under different hemodynamic states.

N N Musewe1, J F Smallhorn, L N Benson, P E Burrows, R M Freedom.   

Abstract

Twenty-nine patients with a patent ductus arteriosus (PDA) in isolation (n = 17) or in combination with other lesions (n = 12) underwent simultaneous hemodynamic assessment and evaluation of PDA flow velocity by the Doppler method. The accuracy with which Doppler velocity across the PDA predicted pulmonary arterial pressure and the influence of PDA size and shape on the Doppler velocity-pressure relationship were examined. Seventy percent had a cone-shaped PDA (narrowest at the pulmonary artery end), and the remainder were tubular. Narrowest PDA diameter ranged from 1.5 to 9 mm (mean 3.5 mm). Peak systolic and mean pulmonary arterial pressure ranged from 10 to 116 and 8 to 72 mm Hg, respectively. Twenty-one patients (group 1) had left-to-right shunting only. The following variables showed significant correlation in this group: peak instantaneous systolic aortic-to-main pulmonary arterial (MPA) pressure gradient and maximum Doppler velocity across the PDA (slope = 1.03, SEE = 13 mm Hg, r = .94, p less than .001), mean aortic-to-MPA pressure gradient and mean Doppler velocity (slope = 1.06, SEE = 10 mm Hg, r = .95, p less than .001), and end diastolic aortic-to-MPA pressure gradient and minimum Doppler velocity (slope = 1.12, SEE = 8 mm Hg, r = .96, p less than .001). Eight patients (group 2) had bidirectional shunting. In this group peak instantaneous aortic-to-MPA pressure gradient significantly correlated with maximum Doppler velocity measured from the left-to-right shunt (slope = .70, SEE = 2 mm Hg, r = .92, p less than .002) and mean pressure gradient correlated with mean Doppler velocity (slope = .83, SEE = 3 mm Hg, r = .78, p less than .003). Right-to-left Doppler velocities showed no correlation with pressures. In six patients with pulmonary hypertension Doppler velocity changes accurately predicted the effect of pulmonary vasodilation on pulmonary arterial pressure. Doppler velocity of PDA flow reliably predicts pulmonary arterial pressure over a wide range of pressures and PDA shapes and sizes.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 2959394     DOI: 10.1161/01.cir.76.5.1081

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  18 in total

1.  Evaluation of pulmonary arterial pressure by Doppler colour flow mapping in patients with a ductus arteriosus.

Authors:  K Aziz; H Tasneem
Journal:  Br Heart J       Date:  1990-05

2.  Non-invasive assessment of pulmonary arterial pressure in healthy neonates.

Authors:  J R Skinner; R J Boys; S Hunter; E N Hey
Journal:  Arch Dis Child       Date:  1991-04       Impact factor: 3.791

Review 3.  Perioperative echocardiographic evaluation.

Authors:  R G Williams
Journal:  Int J Card Imaging       Date:  1989

4.  Bidirectional flow through the ductus arteriosus in normal newborns: evaluation by Doppler color flow imaging.

Authors:  H Shiraishi; M Yanagisawa
Journal:  Pediatr Cardiol       Date:  1991-10       Impact factor: 1.655

5.  Postnatal circulatory adaptation in healthy term and preterm neonates.

Authors:  N J Evans; L N Archer
Journal:  Arch Dis Child       Date:  1990-01       Impact factor: 3.791

6.  Doppler flow characteristics in the assessment of pulmonary artery pressure in ductus arteriosus.

Authors:  A B Houston; M K Lim; W B Doig; J Gnanapragasam; E N Coleman; M P Jamieson; J C Pollock
Journal:  Br Heart J       Date:  1989-10

7.  Pulmonary and systemic arterial pressure in hyaline membrane disease.

Authors:  J R Skinner; R J Boys; S Hunter; E N Hey
Journal:  Arch Dis Child       Date:  1992-04       Impact factor: 3.791

8.  Pulmonary haemodynamics after surfactant replacement in severe neonatal respiratory distress syndrome.

Authors:  M C Bloom; M Roques-Gineste; F Fries; M C Lelong-Tissier
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-09       Impact factor: 5.747

Review 9.  Echocardiography in the diagnosis of thoracic aortic pathology.

Authors:  F D Tice; J Kisslo
Journal:  Int J Card Imaging       Date:  1993

10.  Usefulness of Doppler derived end diastolic flow gradient across the patent ductus arteriosus in selecting coils for ductal occlusion.

Authors:  Amit Kumar Chaurasia; S Harikrishnan; S Bijulal; K M Krishnamoorthy; S Sivasankaran; J A Tharakan
Journal:  Pediatr Cardiol       Date:  2011-10-04       Impact factor: 1.655