Tom Haynes1, Chris Bishop2, Mark Antrobus3, Jon Brazier4. 1. Center of Applied Science, City and Islington College, London, UK. 2. London Sport Institute, Middlesex University, London, UK. 3. Sport, Exercise and Life Sciences, University of Northampton, Northampton, UK. 4. Center of Applied Science, City and Islington College, London, UK - Jonnybrazier@hotmail.com.
Abstract
BACKGROUND: This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). METHODS: Fourteen male sport science students (age: 29.5±9.9 years) performed three drop jumps from 20 cm and 40 cm (totaling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and Bland-Altman plots. RESULTS: Near perfect agreement was seen between devices at 20 cm for RSI (ICC=0.95) and contact time (ICC=0.99) and at 40 cm for RSI (ICC=0.98), jump height (ICC=0.96) and contact time (ICC=0.92); with very strong agreement seen at 20 cm for jump height (ICC=0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r=0.94; 40 cm; r=0.97), jump height (20 cm: r=0.80; 40 cm; r=0.96) and contact time (20 cm=0.96; 40 cm; r=0.98). CONCLUSIONS: The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.
BACKGROUND: This is the first study to independently assess the concurrent validity and reliability of the My Jump 2 app for measuring drop jump performance. It is also the first to evaluate the app's ability to measure the reactive strength index (RSI). METHODS: Fourteen male sport science students (age: 29.5±9.9 years) performed three drop jumps from 20 cm and 40 cm (totaling 84 jumps), assessed via a force platform and the My Jump 2 app. Reported metrics included reactive strength index, jump height, ground contact time, and mean power. Measurements from both devices were compared using the intraclass correlation coefficient (ICC), Pearson product moment correlation coefficient (r), Cronbach's alpha (α), coefficient of variation (CV) and Bland-Altman plots. RESULTS: Near perfect agreement was seen between devices at 20 cm for RSI (ICC=0.95) and contact time (ICC=0.99) and at 40 cm for RSI (ICC=0.98), jump height (ICC=0.96) and contact time (ICC=0.92); with very strong agreement seen at 20 cm for jump height (ICC=0.80). In comparison with the force plate the app showed good validity for RSI (20 cm: r=0.94; 40 cm; r=0.97), jump height (20 cm: r=0.80; 40 cm; r=0.96) and contact time (20 cm=0.96; 40 cm; r=0.98). CONCLUSIONS: The results of the present study show that the My Jump 2 app is a valid and reliable tool for assessing drop jump performance.
Authors: Felipe García-Pinillos; Pascual Bujalance-Moreno; Carlos Lago-Fuentes; Santiago A Ruiz-Alias; Irma Domínguez-Azpíroz; Marcos Mecías-Calvo; Rodrigo Ramirez-Campillo Journal: Int J Environ Res Public Health Date: 2021-04-30 Impact factor: 3.390
Authors: Špela Bogataj; Maja Pajek; Vedran Hadžić; Slobodan Andrašić; Johnny Padulo; Nebojša Trajković Journal: Int J Environ Res Public Health Date: 2020-05-25 Impact factor: 3.390
Authors: Rejane Maria Cruvinel-Cabral; Iransé Oliveira-Silva; André Ricarte Medeiros; João Gustavo Claudino; Pedro Jiménez-Reyes; Daniel A Boullosa Journal: PeerJ Date: 2018-10-15 Impact factor: 2.984