Literature DB >> 2958530

Evaluation of left ventricular systolic and diastolic dysfunction during transient myocardial ischemia produced by angioplasty.

A J Labovitz1, M K Lewen, M Kern, M Vandormael, U Deligonal, H L Kennedy.   

Abstract

Acute myocardial ischemia is known to cause impairment of both left ventricular systolic and diastolic function. To further investigate these changes as well as their relation to common clinical variables (electrocardiographic [ECG] changes and chest pain), 32 patients were evaluated with Doppler echocardiography during coronary angioplasty. Doppler indexes of left ventricular diastolic function included the ratios of peak early to late and peak early to mean diastolic velocities as well as the ratios of early to late and first third to total velocity integral (one-third filling fraction). All diastolic indexes showed significant impairment by 15 seconds after coronary occlusion (ratio peak early to late filling velocity: 1.11 versus 0.96, p less than 0.01; ratio peak early to mean filling velocity: 1.9 versus 1.7, p less than 0.01; ratio early to late velocity integral: 1.58 versus 1.25, p less than 0.01; one-third filling fraction: 41.2 versus 37.7, p less than 0.01). Left ventricular systolic function was evaluated during coronary occlusion both qualitatively, as assessed by the appearance of a new wall motion abnormality on two-dimensional echocardiography (mean 28.8 seconds), and quantitatively by measurement of systolic percent area change on the two-dimensional short-axis view as well as the Doppler echocardiographic stroke integral index. Systolic indexes did not show significant change until 30 seconds after balloon inflation (percent area change: 42.8 versus 29.2, p less than 0.01; stroke integral index: 11.04 versus 9.36, p less than 0.01). ECGs were performed at 15 second intervals.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 2958530     DOI: 10.1016/s0735-1097(87)80266-8

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  27 in total

1.  Left ventricular electromechanical mapping: a case study of functional assessment in coronary intervention.

Authors:  E C Perin; G V Silva; R Sarmento-Leite
Journal:  Tex Heart Inst J       Date:  2000

2.  Transmitral velocities measured by pulsed Doppler in healthy volunteers: effects of acute changes in blood pressure and heart rate.

Authors:  S A Smith; J E Stoner; A E Russell; J M Sheppard; P E Aylward
Journal:  Br Heart J       Date:  1989-04

3.  Thoracic epidural blockade preserves left ventricular early diastolic filling assessed by transesophageal echocardiography.

Authors:  Toshiya Shiga
Journal:  J Anesth       Date:  1998-03       Impact factor: 2.078

4.  Long axis electromechanics during dobutamine stress in patients with coronary artery disease and left ventricular dysfunction.

Authors:  A M Duncan; C A O'Sullivan; G S Carr-White; D G Gibson; M Y Henein
Journal:  Heart       Date:  2001-10       Impact factor: 5.994

5.  Usefulness of echocardiography and Doppler in the detection of segmental myocardial ischemia.

Authors:  M C Herregods; I de Scheerder; H de Geest; F van der Werf
Journal:  Int J Card Imaging       Date:  1993-12

6.  Effect of anemia correction on left ventricular structure and filling pressure in anemic patients without overt heart disease.

Authors:  In-Jeong Cho; Yeung Chul Mun; Ki Hwan Kwon; Gil Ja Shin
Journal:  Korean J Intern Med       Date:  2014-06-27       Impact factor: 2.884

7.  Left ventricular diastolic filling during coronary artery bypass surgery in patients with diabetes mellitus and/or hypertension.

Authors:  Hiroshi Kitahata; Michihisa Kato; Kazumasa Orihashi; Paul L Goldiner; Yasu Oka
Journal:  J Anesth       Date:  1994-06       Impact factor: 2.078

8.  The effects of iron deficiency anemia on p wave duration and dispersion.

Authors:  Hakki Simsek; Yilmaz Gunes; Cengiz Demir; Musa Sahin; Hasan Ali Gumrukcuoglu; Mustafa Tuncer
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

9.  Changes in myocardial echo amplitude during reversible ischaemia in humans.

Authors:  D A Lythall; D G Gibson; S S Kushwaha; M S Norell; A G Mitchell; C J Ilsley
Journal:  Br Heart J       Date:  1992-05

Review 10.  Clinical relevance of myocardial "stunning".

Authors:  R Bolli; C J Hartley; R S Rabinovitz
Journal:  Cardiovasc Drugs Ther       Date:  1991-10       Impact factor: 3.727

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.