PURPOSE: Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the relevant x-ray energy ranges. In this work, we present a preclinical Talbot-Lau prototype capable of imaging human-sized objects with proper image quality at clinically acceptable dose levels. METHODS: The TLI is designed to match a setup of clinical relevance as closely as possible. The system provides a scan range of 120 × 30 cm2 by using a scanning beam geometry. Its ultimate load is 100 kg. High aspect ratios and fine grid periods of the gratings ensure a reasonable setup length and clinically relevant image quality. The system is installed in a university hospital and is, therefore, exposed to the external influences of a clinical environment. To demonstrate the system's capabilities, a full-body scan of a euthanized pig was performed. In addition, freshly excised porcine lungs with an extrinsically provoked pneumothorax were mounted into a human thorax phantom and examined with the prototype. RESULTS: Both examination sequences resulted in clinically relevant image quality - even in the case of a skin entrance air kerma of only 0.3 mGy which is in the range of human thoracic imaging. The presented case of a pneumothorax and a reader study showed that the prototype's dark-field images provide added value for pulmonary diagnosis. CONCLUSION: We demonstrated that a dedicated design of a Talbot-Lau interferometer can be applied to medical imaging by constructing a preclinical Talbot-Lau prototype. We experienced that the system is feasible for imaging human-sized objects and the phase-stepping approach is suitable for clinical practice. Hence, we conclude that Talbot-Lau x-ray imaging has potential for clinical use and enhances the diagnostic power of medical x-ray imaging.
PURPOSE: Talbot-Lau x-ray interferometry provides information about the scattering and refractive properties of an object - in addition to the object's attenuation features. Until recently, this method was ineligible for imaging human-sized objects as it is challenging to adapt Talbot-Lau interferometers (TLIs) to the relevant x-ray energy ranges. In this work, we present a preclinical Talbot-Lau prototype capable of imaging human-sized objects with proper image quality at clinically acceptable dose levels. METHODS: The TLI is designed to match a setup of clinical relevance as closely as possible. The system provides a scan range of 120 × 30 cm2 by using a scanning beam geometry. Its ultimate load is 100 kg. High aspect ratios and fine grid periods of the gratings ensure a reasonable setup length and clinically relevant image quality. The system is installed in a university hospital and is, therefore, exposed to the external influences of a clinical environment. To demonstrate the system's capabilities, a full-body scan of a euthanized pig was performed. In addition, freshly excised porcine lungs with an extrinsically provoked pneumothorax were mounted into a human thorax phantom and examined with the prototype. RESULTS: Both examination sequences resulted in clinically relevant image quality - even in the case of a skin entrance air kerma of only 0.3 mGy which is in the range of human thoracic imaging. The presented case of a pneumothorax and a reader study showed that the prototype's dark-field images provide added value for pulmonary diagnosis. CONCLUSION: We demonstrated that a dedicated design of a Talbot-Lau interferometer can be applied to medical imaging by constructing a preclinical Talbot-Lau prototype. We experienced that the system is feasible for imaging human-sized objects and the phase-stepping approach is suitable for clinical practice. Hence, we conclude that Talbot-Lau x-ray imaging has potential for clinical use and enhances the diagnostic power of medical x-ray imaging.
Authors: Susan Notohamiprodjo; Karla Maria Treitl; Christian Hauke; Sven-Martin Sutter; Sigrid Auweter; Franz Pfeiffer; Maximilian Ferdinand Reiser; Katharina Hellbach Journal: Sci Rep Date: 2020-06-10 Impact factor: 4.379
Authors: Jana Andrejewski; Fabio De Marco; Konstantin Willer; Wolfgang Noichl; Alex Gustschin; Thomas Koehler; Pascal Meyer; Fabian Kriner; Florian Fischer; Christian Braun; Alexander A Fingerle; Julia Herzen; Franz Pfeiffer; Daniela Pfeiffer Journal: Eur Radiol Exp Date: 2021-01-26
Authors: Jana Andrejewski; Fabio De Marco; Konstantin Willer; Wolfgang Noichl; Theresa Urban; Manuela Frank; Alex Gustschin; Pascal Meyer; Thomas Koehler; Franz Pfeiffer; Julia Herzen Journal: Sci Rep Date: 2021-12-06 Impact factor: 4.379