Literature DB >> 29581040

Female False Positive Exercise Stress ECG Testing - Fact Versus Fiction.

Benjamin T Fitzgerald1, William M Scalia2, Gregory M Scalia3.   

Abstract

BACKGROUND: Exercise stress testing is a well validated cardiovascular investigation. Accuracy for treadmill stress electrocardiograph (ECG) testing has been documented at 60%. False positive stress ECGs (exercise ECG changes with non-obstructive disease on anatomical testing) are common, especially in women, limiting the effectiveness of the test. This study investigates the incidence and predictors of false positive stress ECG findings, referenced against stress echocardiography (SE) as a standard.
METHODS: Stress echocardiography was performed using the Bruce treadmill protocol. False positive stress ECG tests were defined as greater than 1mm of ST depression on ECG during exertion, without pain, with a normal SE. Potential causes for false positive tests were recorded before the test.
RESULTS: Three thousand (3,000) consecutive negative stress echocardiograms (1,036 females, 34.5%) were analysed (age 59+/-14 years. False positive (F+) stress ECGs were documented in 565/3,000 tests (18.8%). F+ stress ECGs were equally prevalent in females (194/1,036, 18.7%) and males (371/1,964, 18.9%, p=0.85 for the difference). Potential causes (hypertension, left ventricular hypertrophy, known coronary disease, arrhythmia, diabetes mellitus, valvular heart disease) were recorded in 36/194 (18.6%) of the female F+ ECG tests and 249/371 (68.2%) of the male F+ ECG tests (p<0.0001 for the difference).
CONCLUSIONS: These data suggest that F+ stress ECG tests are frequent and equally common in women and men. However, most F+ stress ECGs in men can be predicted before the test, while most in women cannot. Being female may be a risk factor in itself. These data reinforce the value of stress imaging, particularly in women.
Copyright © 2018 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). All rights reserved.

Entities:  

Keywords:  False positive; Female; Predictors; Stress echocardiography; Stress testing

Mesh:

Year:  2018        PMID: 29581040     DOI: 10.1016/j.hlc.2018.02.010

Source DB:  PubMed          Journal:  Heart Lung Circ        ISSN: 1443-9506            Impact factor:   2.975


  2 in total

1.  Gauging the Positive Predictive Value of Exercise Tolerance Test Using Angiographic Evaluation: A Cross-Sectional Analysis From a Developing Country.

Authors:  Ismail Khan; Maria Hasan; Javeria Hasan; Ali Imran Dhillon; Moosa Khan; Mehwish Kaneez
Journal:  Cureus       Date:  2020-12-19

2.  A Novel Index for Prompt Prediction of Severity in Patients with Unstable Angina Pectoris.

Authors:  Mustafa Bolatkale; Ahmet Cagdas Acara
Journal:  Emerg Med Int       Date:  2020-01-03       Impact factor: 1.112

  2 in total