Assessment of the relationship between distal occluded pressure and angiographically evident collateral flow during coronary angioplasty.

J P Dervan, R G McKay, D S Baim.   

Abstract

The relationship between the presence of collateral filling on the baseline coronary angiogram and the distal occluded pressure obtained during balloon inflation was examined in 83 patients undergoing coronary angioplasty. The patients were divided into three groups: Group I (n = 40) had conventional stenoses (80% to 95% luminal diameter narrowing) without angiographically evident collaterals, group II (n = 22) had conventional stenoses with angiographically present collaterals, and group III (n = 21) had total or functional total occlusions (99% to 100% diameter narrowing) with angiographically evident collateral flow. There was no significant difference in age, sex, vessel distribution, clinical class, residual gradient, or residual percent stenosis following successful angioplasty among the three groups. The distal occluded pressure in group I (18 +/- 5 mm Hg) was, however, significantly lower than the distal occluded pressure in either group II (34 +/- 7 mm Hg) or group III (36 +/- 9 mm Hg) (p less than 0.001). This could not be explained by differences in aortic pressure, since there was no correlation between the mean aortic blood pressure and the distal occluded pressure and since the distal occluded pressure/aortic pressure ratio in group I (0.23 +/- 0.07) was significantly lower than that of group II (0.41 +/- 0.09) or group III (0.41 +/- 0.11) (p less than 0.001). These findings indicate a close correlation between the presence of angiographically evident collateral flow and the distal coronary artery pressure during an angioplasty balloon inflation.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1987        PMID: 2957899     DOI: 10.1016/0002-8703(87)90743-5

Source DB:  PubMed          Journal:  Am Heart J        ISSN: 0002-8703            Impact factor:   4.749


  2 in total

1.  Coronary collateral flow reversal.

Authors:  M Carlier; L Finci; B Meier
Journal:  Heart Vessels       Date:  1991       Impact factor: 2.037

2.  Donor artery stenosis interactions with diastolic blood pressure on coronary collateral flow in type 2 diabetic patients with chronic total occlusion.

Authors:  Ying Shen; Zhen Kun Yang; Jian Hu; Xiao Qun Wang; Yang Dai; Su Zhang; Rui Yan Zhang; Lin Lu; Feng Hua Ding; Wei Feng Shen
Journal:  Cardiovasc Diabetol       Date:  2018-06-01       Impact factor: 9.951

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.