Emine Hekim Yılmaz, Mustafa Orhan Bulut, Mehmet Küçük, İlker Kemal Yücel1, Abdullah Erdem, Ahmet Çelebi.
Abstract
OBJECTIVE: To report clinical and procedural characteristics of twelve patients who received a covered stent for the treatment of aortic coarctation and concurrent patent ductus arteriosus (PDA).Entities:
Mesh:
Year: 2018 PMID: 29578201 PMCID: PMC5998845 DOI: 10.14744/AnatolJCardiol.2018.61257
Source DB: PubMed Journal: Anatol J Cardiol ISSN: 2149-2263 Impact factor: 1.596
Demographic characteristics and procedural data
| Age | Weight | PDA | Additional | PHT | Preprocedural | Postprocedural | Balloon | size Balloon | Stent type | Stent length | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| (years) | (kg) | type | findings | Systemic HT | Systemic HT | (mm) | type | (mm) | |||
| Case 1 | 26 | 28 | C | VSD, BAV | + | + | + | 16x4 | BIB | Covered CP | 45 |
| Case 2 | 6.5 | 19 | B | - | - | + | - | 10x3 | Z Med | Covered CP | 34 |
| Case 3 | 16 | 55 | E | BAV | - | + | + | 12x4 | BIB | Covered CP | 34 |
| Case 4 | 12 | 38 | C | VSD+ASD | + | + | - | 16x4 | BIB | Covered CP | 34 |
| Case 5 | 35 | 73 | E | BAV | - | + | - | 18x4 | BIB | Covered CP | 45 |
| Case 6 | 22 | 84 | E | - | - | + | - | 20x3.5 | BIB | Covered CP | 28 |
| Case 7 | 12 | 19 | E | VSD (small) | - | + | - | 13x3 | Z Med | Covered CP | 28 |
| Case 8 | 25 | 60 | A | - | - | + | + | 20x3.5 | BIB | Covered CP | 34 |
| Case 9 | 10 | 26 | C | BAV | + | + | - | 14x3 | BIB | Covered CP | 22 |
| Case 10 | 15 | 53 | C | BAV+SAR | + | + | + | 20x4 | BIB | Covered CP | 39 |
| Case 11 | 13 | 42 | E | - | - | + | + | 16x4 | BIB | Covered CP | 34 |
| Case 12 | 14 | 57 | E | - | - | + | - | 18x4 | BIB | Covered CP | 39 |
BAV - bicuspid aortic valve; PHT - pulmonary hypertension; HT – hypertension; PDA - patent ductus arteriosus; BIB - balloon-in-balloon; CP - cheatham-platinum; SAR - subaortic ridge; VSD - ventricular septal defect
Figure 1Angiogram of a patient with a mild to moderate coarctation and large PDA (a); a 34-mm covered stent mounted on a 16-mm balloon was advanced across the coarctation segment (b) and then implanted (c); however, there was significant shunt through the duct after the implantation due to the gap between the distal end of the stent and the poststenotic dilated segment of the aorta (c); postdilation of the distal part of the stent with 20-mm and 23-mm low-pressure balloons (d, e); closed the gap between the aortic wall and covered stent. Finally, there was no residual shunt through PDA (f)