| Literature DB >> 29576877 |
Ling Wang1, Gang Yin2, Zhiying Yu1, Nan Chen1, Dabo Wang1.
Abstract
PURPOSE: To investigate changes in eye coats, axial length, and ocular perfusion pressure (OPP) in hemodialysis (HD) patients with chronic renal failure (CRF).Entities:
Year: 2018 PMID: 29576877 PMCID: PMC5822860 DOI: 10.1155/2018/3105138
Source DB: PubMed Journal: J Ophthalmol ISSN: 2090-004X Impact factor: 1.909
General characteristics of the patients.
| Variable | Mean | SD | Range |
|---|---|---|---|
| Age (years) | 52.4 | 10.1 | 40–68 |
| Hemodialysis duration (year) | 6.1 | 1.9 | 4–10 |
| Total amount of ultrafiltration (mL) | 2318 | 612.3 | 1500–3100 |
| Weight loss (kg) | 2.10 | 0.91 | 0.95–2.95 |
Figure 1Iris thickness (IT) and ciliary body thickness (CBT) measurements by ultrasound biomicroscopy. IT was 0.43 mm and CBT was 0.61 mm.
Figure 2Choroid and retinal thickness measurements by optical coherence tomography.
Effect of hemodialysis on plasma osmotic pressure and blood biochemical parameters.
| Variable | Urea nitrogen (mmol/l) | Glucose (mmol/l) | Na+ (mmol/l) | Creatinine ( | Plasma osmotic pressure (mOsm/kg H2O) |
|---|---|---|---|---|---|
| Pre-HD | 26.06 ± 5.48 | 5.96 ± 1.19 | 138.18 ± 2.40 | 909.22 ± 119.93 | 279.37 ± 6.16 |
| Post-HD | 8.92 ± 3.79 | 7.85 ± 3.25 | 137.98 ± 4.35 | 395.52 ± 118.92 | 270.54 ± 7.32 |
Effect of hemodialysis on systolic blood pressure, diastolic blood pressure, intraocular pressure, and ocular perfusion pressure.
| Variable | Pre-HD | 2 h of HD | Post-HD |
|---|---|---|---|
| SBP | 135.19 ± 17.28 | 123.28 ± 18.56 | 133.03 ± 18.89 |
| DBP | 76.98 ± 14.02 | 74.26 ± 16.90 | 77.84 ± 15.07 |
| IOP | 16.87 ± 3.92 | 17.24 ± 3.64 | 17.42 ± 4.51 |
| OPP | 53.75 ± 7.80 | 50.67 ± 9.89 | 55.23 ± 9.73 |
Effect of hemodialysis on the structure of the eye coats.
| Variable | Pre-HD | Post-HD |
|
|
|---|---|---|---|---|
| CCT | 0.506 ± 0.025 | 0.504 ± 0.023 | 1.252 | >0.05 |
| IT | 0.380 ± 00.64 | 0.372 ± 0.061 | 1.607 | >0.05 |
| CBT | 0.684 ± 0.059 | 0.668 ± 0.057 | 3.461 | <0.01 |
| CT (fovea) | 267.97 ± 99.17 | 255.87 ± 95.59 | 6.240 | <0.01 |
| CT (nasal side 1500 | 197.84 ± 95.43 | 186.29 ± 91.44 | 6.169 | <0.01 |
| CT (temporal side 1500 | 233.37 ± 84.88 | 219.66 ± 83.04 | 3.405 | <0.01 |
| RT (fovea) | 207.88 ± 23.47 | 209.94 ± 24.41 | −2.265 | <0.05 |
| RT (nasal side 1500 | 341.42 ± 23.32 | 343.88 ± 23.94 | −2.624 | <0.05 |
| RT (temporal side 1500 | 312.52 ± 22.90 | 314.15 ± 23.97 | −2.220 | <0.05 |
Effect of hemodialysis on ocular axis-related parameters.
| Variable | Pre-HD | Post-HD |
|
|
|---|---|---|---|---|
| ACD | 2.74 ± 0.24 | 2.70 ± 0.29 | 1.439 | >0.05 |
| LT | 4.85 ± 0.41 | 4.90 ± 0.43 | −2.076 | <0.05 |
| VAL | 15.43 ± 0.82 | 15.48 ± 0.82 | −3.817 | <0.01 |
| EAL | 23.04 ± 0.79 | 23.10 ± 0.79 | −4.010 | <0.01 |