Literature DB >> 29575739

Numerical zero-dimensional hepatic artery hemodynamics model for balloon-occluded transarterial chemoembolization.

Jorge Aramburu1, Raúl Antón1,2, Alejandro Rivas1, Juan Carlos Ramos1, Gorka S Larraona1, Bruno Sangro2,3,4, José Ignacio Bilbao2,3.   

Abstract

Balloon-occluded transarterial chemoembolization (B-TACE) is a valuable treatment option for patients with inoperable malignant tumors in the liver. Balloon-occluded transarterial chemoembolization consists of the transcatheter infusion of an anticancer drug mixture and embolic agents. Contrary to conventional TACE, B-TACE is performed via an artery-occluding microballoon catheter, which makes the blood flow to redistribute due to the intra- and extrahepatic arterial collateral circulation. Several recent studies have stressed the importance of the redistribution of blood flow in enhancing the treatment outcome. In the present study, the geometries of a representative hepatic artery and the communicating arcades (CAs) are modeled. An in silico zero-dimensional hemodynamic model is created by characterizing the geometry and the boundary conditions and then is validated in vitro. The role of CAs is assessed by combining 2 cancer scenarios and 2 catheter locations. The importance of the diameter of the CAs is also studied. Results show that occluding a main artery leads to collateral circulation and CAs start to play a role in blood-flow redistribution. In summary, numerical zero-dimensional simulations permit a fast and reliable approach for exploring the blood-flow redistribution caused by the occlusion of a main artery, and this approach could be used during B-TACE planning.
Copyright © 2018 John Wiley & Sons, Ltd.

Entities:  

Keywords:  balloon-occluded arterial stump pressure; boundary conditions; collateral circulation; communicating arcade; liver cancer

Mesh:

Year:  2018        PMID: 29575739     DOI: 10.1002/cnm.2983

Source DB:  PubMed          Journal:  Int J Numer Method Biomed Eng        ISSN: 2040-7939            Impact factor:   2.747


  5 in total

1.  Balloon-Occluded Transcatheter Arterial Chemoembolization (b-TACE) for Hepatocellular Carcinoma Performed with Polyethylene-Glycol Epirubicin-Loaded Drug-Eluting Embolics: Safety and Preliminary Results.

Authors:  Pierleone Lucatelli; Luca Ginnani Corradini; Gianluca De Rubeis; Bianca Rocco; Fabrizio Basilico; Alessandro Cannavale; Pier Giorgio Nardis; Mario Corona; Luca Saba; Carlo Catalano; Mario Bezzi
Journal:  Cardiovasc Intervent Radiol       Date:  2019-03-06       Impact factor: 2.740

2.  Computational Modeling of the Liver Arterial Blood Flow for Microsphere Therapy: Effect of Boundary Conditions.

Authors:  Amirtahà Taebi; Rex M Pillai; Bahman S Roudsari; Catherine T Vu; Emilie Roncali
Journal:  Bioengineering (Basel)       Date:  2020-06-29

3.  Balloon-occluded chemoembolization for hepatocellular carcinoma: a prospective study of safety, feasibility and outcomes.

Authors:  Ana-Maria Bucalau; Illario Tancredi; Martina Pezzullo; Raphael Leveque; Simona Picchia; Jean-Luc Van Laethem; Gontran Verset
Journal:  Hepat Oncol       Date:  2020-10-13

Review 4.  Computational Fluid Dynamics Modeling of Liver Radioembolization: A Review.

Authors:  Jorge Aramburu; Raúl Antón; Macarena Rodríguez-Fraile; Bruno Sangro; José Ignacio Bilbao
Journal:  Cardiovasc Intervent Radiol       Date:  2021-09-13       Impact factor: 2.740

5.  In Vitro Model for Simulating Drug Delivery during Balloon-Occluded Transarterial Chemoembolization.

Authors:  Jorge Aramburu; Raúl Antón; Junichi Fukamizu; Daiki Nozawa; Makoto Takahashi; Kouji Ozaki; Juan Carlos Ramos; Bruno Sangro; José Ignacio Bilbao; Kosuke Tomita; Tomohiro Matsumoto; Terumitsu Hasebe
Journal:  Biology (Basel)       Date:  2021-12-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.