Development of a Smart Mobile Data Module for Fetal Monitoring in E-Healthcare.

Agathe Houzé de l'Aulnoit1,2, Samuel Boudet3, Michaël Génin4, Pierre-François Gautier5, Jessica Schiro5, Denis Houzé de l'Aulnoit6, Régis Beuscart4.   

Abstract

The fetal heart rate (FHR) is a marker of fetal well-being in utero (when monitoring maternal and/or fetal pathologies) and during labor. Here, we developed a smart mobile data module for the remote acquisition and transmission (via a Wi-Fi or 4G connection) of FHR recordings, together with a web-based viewer for displaying the FHR datasets on a computer, smartphone or tablet. In order to define the features required by users, we modelled the fetal monitoring procedure (in home and hospital settings) via semi-structured interviews with midwives and obstetricians. Using this information, we developed a mobile data transfer module based on a Raspberry Pi. When connected to a standalone fetal monitor, the module acquires the FHR signal and sends it (via a Wi-Fi or a 3G/4G mobile internet connection) to a secure server within our hospital information system. The archived, digitized signal data are linked to the patient's electronic medical records. An HTML5/JavaScript web viewer converts the digitized FHR data into easily readable and interpretable graphs for viewing on a computer (running Windows, Linux or MacOS) or a mobile device (running Android, iOS or Windows Phone OS). The data can be viewed in real time or offline. The application includes tools required for correct interpretation of the data (signal loss calculation, scale adjustment, and precise measurements of the signal's characteristics). We performed a proof-of-concept case study of the transmission, reception and visualization of FHR data for a pregnant woman at 30 weeks of amenorrhea. She was hospitalized in the pregnancy assessment unit and FHR data were acquired three times a day with a Philips Avalon® FM30 fetal monitor. The prototype (Raspberry Pi) was connected to the fetal monitor's RS232 port. The emission and reception of prerecorded signals were tested and the web server correctly received the signals, and the FHR recording was visualized in real time on a computer, a tablet and smartphones (running Android and iOS) via the web viewer. This process did not perturb the hospital's computer network. There was no data delay or loss during a 60-min test. The web viewer was tested successfully in the various usage situations. The system was as user-friendly as expected, and enabled rapid, secure archiving. We have developed a system for the acquisition, transmission, recording and visualization of RCF data. Healthcare professionals can view the FHR data remotely on their computer, tablet or smartphone. Integration of FHR data into a hospital information system enables optimal, secure, long-term data archiving.

Entities:  

Keywords:  Archiving; Fetal heart rate recording; Fetal monitoring; Smart device

Mesh:

Year:  2018        PMID: 29572752     DOI: 10.1007/s10916-018-0938-1

Source DB:  PubMed          Journal:  J Med Syst        ISSN: 0148-5598            Impact factor:   4.460


  12 in total

1.  Improving the quality of health care in the United Kingdom and the United States: a framework for change.

Authors:  E B Ferlie; S M Shortell
Journal:  Milbank Q       Date:  2001       Impact factor: 4.911

2.  Telemedicine and remote patient monitoring.

Authors:  Marilyn J Field; Jim Grigsby
Journal:  JAMA       Date:  2002 Jul 24-31       Impact factor: 56.272

3.  The development of an obstetric tele-monitoring system.

Authors:  B Vermeulen-Giovagnoli; C Peters; M B van der Hout-van der Jagt; M Mischi; C van Pul; E J E Cottaar; S G Oei
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2015

Review 4.  Medical laboratory informatics.

Authors:  Liron Pantanowitz; Walter H Henricks; Bruce A Beckwith
Journal:  Clin Lab Med       Date:  2007-12       Impact factor: 1.935

Review 5.  [Modality of fetal heart monitoring during labor (continuous or intermittent), telemetry and central fetal monitoring].

Authors:  F Bretelle; R Le Du; C Foulhy
Journal:  J Gynecol Obstet Biol Reprod (Paris)       Date:  2008-01-09

6.  Obstetric accidents: a review of 64 cases.

Authors:  M Ennis; C A Vincent
Journal:  BMJ       Date:  1990-05-26

Review 7.  Continuous cardiotocography (CTG) as a form of electronic fetal monitoring (EFM) for fetal assessment during labour.

Authors:  Zarko Alfirevic; Declan Devane; Gillian Ml Gyte; Anna Cuthbert
Journal:  Cochrane Database Syst Rev       Date:  2017-02-03

8.  ACOG Practice Bulletin No. 106: Intrapartum fetal heart rate monitoring: nomenclature, interpretation, and general management principles.

Authors: 
Journal:  Obstet Gynecol       Date:  2009-07       Impact factor: 7.661

9.  DICOM for Clinical Research: PACS-Integrated Electronic Data Capture in Multi-Center Trials.

Authors:  Daniel Haak; Charles-E Page; Sebastian Reinartz; Thilo Krüger; Thomas M Deserno
Journal:  J Digit Imaging       Date:  2015-10       Impact factor: 4.056

Review 10.  Antenatal cardiotocography for fetal assessment.

Authors:  Rosalie M Grivell; Zarko Alfirevic; Gillian M L Gyte; Declan Devane
Journal:  Cochrane Database Syst Rev       Date:  2015-09-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.