Literature DB >> 2957111

Detection of transient myocardial ischemia by computer analysis of standard and signal-averaged high-frequency electrocardiograms in patients undergoing percutaneous transluminal coronary angioplasty.

S Abboud, R J Cohen, A Selwyn, P Ganz, D Sadeh, P L Friedman.   

Abstract

Electrocardiographic manifestations of transient myocardial ischemia were studied, in 11 patients undergoing angioplasty (PTCA) of a left anterior descending coronary artery stenosis, by the visual inspection of the standard surface electrocardiogram (S-ECG) and the intracoronary ECG (IC-ECG) as well as computer-assisted analysis of the S-ECG. Cross-correlation analysis (CCA) performed by computer was used to compare beat-to-beat variability in ST-T morphology of the S-ECG during different stages of PTCA. CCA was also applied to the signal-averaged high-frequency QRS (SA-HFQ). All patients developed angina during balloon inflation, accompanied by transient marked ST-T changes in IC-ECG in 10 of 11 patients (90%). Visual inspection of S-ECG revealed transient ST-T changes in only 6 of 11 (54%). In contrast, CCA of the S-ECG revealed transient ST-T changes in 9 of 11 (82%). Analysis of SA-HFQ revealed that balloon inflation was associated with a marked reduction in the calculated root-mean-square (RMS) voltage for such signals (2.31 +/- 1.04 microV) as compared with RMS values before (3.27 +/- 1.12 microV, p less than .05) PTCA or after conclusion of PTCA (3.79 +/- 1.39 microV, p less than .01). Balloon inflation was also accompanied by changes in waveform morphology of the SA-HFQ, including the development of new or more prominent time zones of reduced amplitude in 10 of 11 individuals (90%). Such zones may represent slow conduction in regions of the heart rendered ischemic during PTCA. CCA of the S-ECG and of SA-HFQ appears to detect evidence of transient ischemia with greater sensitivity than simple visual inspection of S-ECG, and may therefore prove to be of use in the evaluation of patients with chest pain of uncertain origin.

Entities:  

Mesh:

Year:  1987        PMID: 2957111     DOI: 10.1161/01.cir.76.3.585

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  13 in total

1.  Intra-QRS spectral changes accompany ST segment changes during episodes of myocardial ischemia.

Authors:  Boris Gramatikov; Vivek Iyer
Journal:  J Electrocardiol       Date:  2014-09-16       Impact factor: 1.438

2.  Sensitivity of epicardial electrical markers to acute ischemia detection.

Authors:  Kedar Aras; Brett Burton; Darrell Swenson; Rob MacLeod
Journal:  J Electrocardiol       Date:  2014-08-17       Impact factor: 1.438

3.  Modeling of the heart's ventricular conduction system using fractal geometry: spectral analysis of the QRS complex.

Authors:  O Berenfeld; D Sadeh; S Abboud
Journal:  Ann Biomed Eng       Date:  1993 Mar-Apr       Impact factor: 3.934

4.  "ECG variability contour" method reveals amplitude changes in both ischemic patients and normal subjects during Dipyridamole stress: a preliminary report.

Authors:  Guy Dori; Michal Gershinsky; Simona Ben-Haim; Basil S Lewis; Haim Bitterman
Journal:  Med Biol Eng Comput       Date:  2011-10-04       Impact factor: 2.602

5.  Lack of impact of myocardial ischemia on the signal-averaged ECG assessment by time-domain analysis.

Authors:  Michael A E Schneider; Christoph A Nienaber
Journal:  Ann Noninvasive Electrocardiol       Date:  2002-07       Impact factor: 1.468

6.  High-frequency QRS analysis in patients with acute myocardial infarction: a preliminary study.

Authors:  Guy Amit; Ori Galante; Linda R Davrath; Oded Luria; Shimon Abboud; Doron Zahger
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-11-22       Impact factor: 1.468

7.  Non-invasive computerised detection of acute coronary occlusion.

Authors:  G Dori; Y Denekamp; S Fishman; A Rosenthal; V Frajewicki; B S Lewis; H Bitterman
Journal:  Med Biol Eng Comput       Date:  2004-05       Impact factor: 2.602

8.  [Magnetcardiographic detection of abnormal intraventricular activation in patients with ischemic heart disease with and without tachycardia].

Authors:  M Oeff; P Gödde; R Agrawal; P Endt; L Trahms; H P Schultheiss
Journal:  Herzschrittmacherther Elektrophysiol       Date:  1997-09

9.  Improved detection of ischemic heart disease by combining high-frequency electrocardiogram analysis with exercise stress echocardiography.

Authors:  Jin-Oh Choi; Sung-A Chang; Sung Ji Park; Sang-Chol Lee; Seung Woo Park
Journal:  Korean Circ J       Date:  2013-10-30       Impact factor: 3.243

10.  High-frequency QRS analysis to supplement ST evaluation in exercise stress electrocardiography: Incremental diagnostic accuracy and net reclassification.

Authors:  Pelbreton C Balfour; Jorge A Gonzalez; Peter W Shaw; Margarita P Caminero; Eric M Holland; Jack W Melson; Michael Sobczak; Valerie Izarnotegui; Denny D Watson; George A Beller; Jamieson M Bourque
Journal:  J Nucl Cardiol       Date:  2018-11-30       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.