Cristina Dominguez1, Mauricio Plata1, Juan Guillermo Cataño1, Mauricio Palau2, Diego Aguirre3, Jorge Narvaez3, Stephanie Trujillo3, Felipe Gómez1, Carlos Gustavo Trujillo1, Juan Ignacio Caicedo1, Camilo Medina1.
Abstract
OBJECTIVES: To evaluate the diagnostic performance of preoperative multiparametric magnetic resonance imaging (mp-MRI) as a predictor of extracapsular extension (ECE) and unfavorable Gleason score (GS) in patients with intermediate and high-risk prostate cancer (PCa).Entities:
Keywords: Magnetic Resonance Imaging; Prostatectomy; Prostatic Neoplasms
Mesh:
Substances:
Year: 2018 PMID: 29570254 PMCID: PMC6092654 DOI: 10.1590/S1677-5538.IBJU.2016.0485
Source DB: PubMed Journal: Int Braz J Urol ISSN: 1677-5538 Impact factor: 1.541
Figure 1Male, 69-year-old patient with prostate cancer Gleason 8 (4+4). (a) RP specimen shows index lesion of 22mm, Gleason 4+5=9 prostate cancer. MRI demonstrate low signal 12mms lesion on T2w images (arrow) in the peripheral zone confined to the prostate (b), there is a focal area of hyper signal in dwi with b value =800 (c) and reduced ADC (d). No extracapsular extension is seen in MRI. PIRADS: T2WI=4/5; DWI=4/5.
Figure 2Male, 61-year-old patient with prostate cancer Gleason 7 (4+3) with ece. (a) RP specimen shows index lesion of 30 mm on left base of the prostate. MRI demonstrates heterogeneous and high signal multinodular in T2w sequences (b), there is no hypervascular lesions and no focal areas of restriction on DWI (c) and ADC images (d). No extracapsular extension is seen on MRI. PIRADS score on MRI: T2WI = 2/5; DWI = 2/5.
Patient and disease characteristics.
| Characteristic | Value | |
|---|---|---|
| Patient Age (years) | 61.1 (39-78, SD±7.50) | |
| PSA Level (ng/mL) | 7.0 (0.02-31, SD±7.25) | |
|
| ||
| T1c | 57 (74.0%) | |
| T2a | 17 (22.1%) | |
| T2b | 2 (2.6%) | |
| T3a | 1 (1.3%) | |
|
| ||
| Intermediate risk | 51 (65.4%) | |
| High risk | 27 (34.6%) | |
|
| ||
| pT2 | 46 (58.2%) | |
| pT3a | 13 (16.5%) | |
| pT3b | 20 (25.3%) | |
|
| ||
| 6 | 6 (7.7%) | |
| 7 | 46 (59%) | |
| 8 | 20 (25.6%) | |
| 9 | 5 (6.4%) | |
| 10 | 1 (1.3%) | |
|
| ||
| 6 | 2 (2.5%) | |
| 7 | 53 (67.1%) | |
| 8 | 14 (17.7%) | |
| 9 | 10 (12.7%) | |
mean and (range, standard deviation);
median and (range, standard deviation);
patient number
Comparison of operative characteristics of mp-MRI in high risk PCa for ECE, SVI, LNI compared to pathology results.
| Study | Sample size (n) | Sensitivity (%) | Specificity (%) | Accuracy (%) | PPV (%) | NPV (%) | |
|---|---|---|---|---|---|---|---|
|
| 922 | ||||||
| ECE | 43 | 84 | 61 | 79 | 52 | ||
| SVI | 35 | 94 | 81 | 62 | 83 | ||
| LNI | 14 | 97 | 92 | 23 | 95 | ||
|
| 85 | ||||||
| ECE | 58 | 98 | - | 95 | 75 | ||
| SVI | 75 | 96 | - | 80 | 94 | ||
|
| 47 | ||||||
| ECE | 72 | 77 | - | 86 | 59 | ||
| SVI | 73 | 95 | - | 95 | 73 | ||
| LNI | 33 | 91 | - | 50 | 84 | ||
|
| 60 | ||||||
| ECE | 35 | 90 | 62 | 79 | 57 | ||
|
| 87 | ||||||
| ECE | 74 | 88 | 83 | 77 | 86 | ||
|
| 183 | ||||||
| ECE | 64.9 | 72.7 | - | 88.9 | 38.1 | ||
1.5T MRI scanner;
3.0T MRI scanner;
Overall using both 1.5T and 3.0T MRI scanner
Figure 3ROC of ADC numeric values in predicting unfavorable GS. AUC value is shown.