Literature DB >> 29570069

A Two-Wired Ultra-High Input Impedance Active Electrode.

Federico Nicolas Guerrero, Enrique Mario Spinelli.   

Abstract

This paper presents a novel two-wired active electrode that achieves ultrahigh input impedance using power supply bootstrapping. The proposed circuit reduces the input capacitance of a buffer amplifier while enabling measurements using leads with only two wires, providing a low-complexity and low-cost solution for interference rejection and artifact reduction in dc-coupled dry-contact biopotential measurements. An implemented prototype shows that, even using standard operational amplifiers, an input capacitance as low as 71 fF can be obtained, maintaining a high impedance in a 0-1 kHz bandwidth, sufficient for ECG, EEG, and EMG measurements. The circuit has a simple and easily replicable implementation that requires no individual adjustment. A common mode rejection ratio (CMRR) above 103 dB at 50 Hz was achieved and the increased rejection to interference due to the potential divider effect was experimentally tested maintaining a 92-dB CMRR at 50 Hz with a 1.2-M source impedance unbalance. ECG measurements were conducted to validate the active electrode against a traditional alternative, and a test with dry-contact EEG electrodes was successfully conducted. Although the proposed circuit is intended to acquire superficial electrophysiological signals using dry electrodes, it can be used for measurement from other high-impedance sources, such as micropipette electrodes.

Mesh:

Year:  2018        PMID: 29570069     DOI: 10.1109/TBCAS.2018.2796581

Source DB:  PubMed          Journal:  IEEE Trans Biomed Circuits Syst        ISSN: 1932-4545            Impact factor:   3.833


  4 in total

1.  In vivo experimental validation of detection of gastric slow waves using a flexible multichannel electrogastrography sensor linear array.

Authors:  Atchariya Sukasem; Stefan Calder; Timothy R Angeli-Gordon; Christopher N Andrews; Gregory O'Grady; Armen Gharibans; Peng Du
Journal:  Biomed Eng Online       Date:  2022-06-27       Impact factor: 3.903

Review 2.  Miniaturization for wearable EEG systems: recording hardware and data processing.

Authors:  Minjae Kim; Seungjae Yoo; Chul Kim
Journal:  Biomed Eng Lett       Date:  2022-06-06

3.  Two-Wired Active Spring-Loaded Dry Electrodes for EEG Measurements.

Authors:  Seungchan Lee; Younghak Shin; Anil Kumar; Kiseon Kim; Heung-No Lee
Journal:  Sensors (Basel)       Date:  2019-10-21       Impact factor: 3.576

4.  An EEG Experimental Study Evaluating the Performance of Texas Instruments ADS1299.

Authors:  Usman Rashid; Imran Khan Niazi; Nada Signal; Denise Taylor
Journal:  Sensors (Basel)       Date:  2018-11-01       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.