Literature DB >> 29567086

Ultrasonographic evaluation of the distance between the flexor pollicis longus tendon and volar prominence of the plate as a function of volar plate positioning and pronator quadratus repair - A cadaver study.

C K Goorens1, K Van Royen2, S Grijseels2, S Provyn3, J De Mey2, T Scheerlinck2, J F Goubau2.   

Abstract

Flexor tendon injury after volar plating of distal radius fractures is due to friction against the plate. To assess this risk, the distance between the flexor pollicis longus (FPL) and the volar prominence of the plate was measured with ultrasonography under various conditions: a standard plate fixed proximal or distal to the watershed line and a low-profile volar rim plate, with and without transection of the pronator quadratus (PQ). Distance from the FPL to the volar prominence of the plate decreased significantly when the PQ was cut and when a standard plate was placed distal to the watershed line, with the tendon often bulging over the plate. No statistical difference was measured between a volar rim plate and a standard plate distal to the watershed line. Our results confirm the importance of positioning the volar plate proximal to the watershed line and of repairing the PQ.
Copyright © 2018 SFCM. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Flexor pollicis longus; Flexor tendon; Ligne de partage des eaux; Plaque palmaire; Pronator quadratus; Tendon fléchisseur; Volar plate; Watershed line

Mesh:

Year:  2018        PMID: 29567086     DOI: 10.1016/j.hansur.2017.12.008

Source DB:  PubMed          Journal:  Hand Surg Rehabil        ISSN: 2468-1210            Impact factor:   0.969


  4 in total

1.  The Watershed Line of the Distal Radius: Cadaveric and Imaging Study of Anatomical Landmarks.

Authors:  Minke Bergsma; Job N Doornberg; Annelise Borghorst; W A Kernkamp; R L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-12-20

2.  Interpretations of the Term "Watershed Line" Used as Reference for Volar Plating.

Authors:  Minke Bergsma; Job N Doornberg; Laurent Hendrickx; Batur Hayat; Gino M M J Kerkhoffs; Bhavin Jhadav; Ruurd L Jaarsma; Gregory I Bain
Journal:  J Wrist Surg       Date:  2019-08-13

3.  IS VOLAR PLATING IN DISTAL RADIUS FRACTURES SAFE REGARDING PRONATOR QUADRATUS?

Authors:  Necmettin Turgut; Turgut Akgül; Fuat Biçen; Türker Şahinkaya; Alper Şükrü Kendirci; Ömer Ayık; Cengiz Şen
Journal:  Acta Ortop Bras       Date:  2022-07-06       Impact factor: 0.683

4.  Anatomical-positional relationship between the bone structure of the distal radius and flexor pollicis longus tendon using ultrasonography.

Authors:  Mayuko Kinoshita; Kiyohito Naito; Kenji Goto; Yoichi Sugiyama; Nana Nagura; Hiroyuki Obata; Yoshiyuki Iwase; Kazuo Kaneko
Journal:  Surg Radiol Anat       Date:  2019-03-16       Impact factor: 1.246

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.