Literature DB >> 29567038

Validating the Patient Reported Outcomes Measurement Information System (PROMIS) computerized adaptive tests for upper extremity fracture care.

Elizabeth B Gausden1, Ashley E Levack2, Danielle N Sin2, Benedict U Nwachukwu2, Peter D Fabricant2, Andrew M Nellestein2, David S Wellman2, Dean G Lorich3.   

Abstract

BACKGROUND: Computerized adaptive testing (CAT) for patient-reported outcomes (PROs) is a developing area within orthopedic surgery. Our objective was to validate the Patient Reported Outcomes Measurement Information System (PROMIS) CATs for upper extremity fracture care. We sought to correlate PROMIS with legacy PROs and to investigate floor and ceiling effects.
METHODS: Patients who underwent open reduction and internal fixation of upper extremity trauma were prospectively enrolled. Legacy PROs included the visual analog scale for pain, the Disabilities of the Arm, Shoulder and Hand questionnaire, the University of California-Los Angeles Shoulder Rating Scale, the Mayo Elbow Performance Score, and the 36-Item Short Form Health Survey. PROMIS CATs included Physical Function (PROMIS PF), PROMIS Pain Interference (PROMIS Pain), and PROMIS Upper Extremity (PROMIS UE). Correlations between the PROs were calculated as were the absolute and relative floor and ceiling effect.
RESULTS: The study prospectively enrolled 174 patients with upper extremity trauma. There was moderate to high correlation between PROMIS UE CAT and legacy upper extremity-specific PROs (ρ = 0.42-0.79), and high correlation between the PROMIS PF CAT and the 36-Item Short Form Health Survey Physical Component Summary (ρ = 0.71, P < .001). The visual analog scale for pain, University of California-Los Angeles Shoulder Rating Scale, Constant Score, and Mayo Elbow Score demonstrated a significant absolute ceiling effect (20.5%-23.7%), whereas the PROMIS PF, PROMIS UE, and PROMIS Pain CATs demonstrated no absolute ceiling effect.
CONCLUSION: PROMIS PF, Pain, and UE correlate well with legacy PROs in a upper extremity trauma population, with less absolute floor or ceiling effects. This study provides preliminary evidence for the utility of PROMIS CATs in upper extremity trauma patients.
Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Patient reported outcomes; ceiling effect; computerized adaptive testing; floor effect; open reduction internal fixation; outcome score validation; upper extremity trauma

Mesh:

Year:  2018        PMID: 29567038     DOI: 10.1016/j.jse.2018.01.014

Source DB:  PubMed          Journal:  J Shoulder Elbow Surg        ISSN: 1058-2746            Impact factor:   3.019


  15 in total

1.  Streamlining Trauma Research Evaluation With Advanced Measurement (STREAM) Study: Implementation of the PROMIS Toolbox Within an Orthopaedic Trauma Clinical Trials Consortium.

Authors:  Anthony R Carlini; Susan C Collins; Elena D Staguhn; Katherine P Frey; Robert V O'Toole; Kristin R Archer; William T Obremskey; Julie Agel; Conor P Kleweno; Saam Morshed; Michael J Weaver; Thomas F Higgins; Michael J Bosse; Joseph F Levy; Albert W Wu; Renan C Castillo
Journal:  J Orthop Trauma       Date:  2022-01-01       Impact factor: 2.512

2.  Preoperative PROMIS Scores Predict Postoperative PROMIS Score Improvement for Patients Undergoing Hand Surgery.

Authors:  David N Bernstein; Jeff R Houck; Ronald M Gonzalez; Danielle M Wilbur; Richard J Miller; David J Mitten; Warren C Hammert
Journal:  Hand (N Y)       Date:  2018-08-03

3.  The PROMIS Upper Extremity Computer Adaptive Test Correlates With Previously Validated Metrics in Patients With Carpal Tunnel Syndrome.

Authors:  Jessica L H Phillips; Mitchell K Freedman; Jeremy I Simon; Pedro K Beredjiklian
Journal:  Hand (N Y)       Date:  2019-06-03

4.  Association of Patient-reported Outcomes With Clinical Outcomes After Distal Humerus Fracture Treatment.

Authors:  Abhiram R Bhashyam; Yassine Ochen; Quirine M J van der Vliet; Luke P H Leenen; Falco Hietbrink; Roderick M Houwert; George S M Dyer; Marilyn Heng
Journal:  J Am Acad Orthop Surg Glob Res Rev       Date:  2020-02-06

5.  Reporting and utilization of Patient-Reported Outcomes Measurement Information System® (PROMIS®) measures in orthopedic research and practice: a systematic review.

Authors:  Maggie E Horn; Emily K Reinke; Logan J Couce; Bryce B Reeve; Leila Ledbetter; Steven Z George
Journal:  J Orthop Surg Res       Date:  2020-11-23       Impact factor: 2.359

6.  The PROMIS CAT Demonstrates Responsiveness in Patients After ACL Reconstruction Across Numerous Health Domains.

Authors:  Caleb M Gulledge; Dylan Koolmees; D Grace Smith; Alexander Pietroski; Sreten Franovic; Vasilios Moutzouros; Eric C Makhni
Journal:  Orthop J Sports Med       Date:  2021-01-22

7.  Protocol for surgical and non-surgical treatment for metacarpal shaft fractures in adults: an observational feasibility study.

Authors:  Rowa Taha; Paul Leighton; Chris Bainbridge; Alan Montgomery; Tim Davis; Alexia Karantana
Journal:  BMJ Open       Date:  2021-06-29       Impact factor: 2.692

8.  Patient-Reported Outcome Measurement Information System (PROMIS) in Orthopaedic Trauma Research.

Authors:  Colin P Sperring; Nicholas C Danford; Bryan M Saltzman; Michael Constant; Nicholas J Dantzker; David P Trofa
Journal:  SICOT J       Date:  2021-07-16

9.  Floor and Ceiling Effects, Time to Completion, and Question Burden of PROMIS CAT Domains Among Shoulder and Knee Patients Undergoing Nonoperative and Operative Treatment.

Authors:  Caleb M Gulledge; D Grace Smith; Alexander Ziedas; Stephanie J Muh; Vasilios Moutzouros; Eric C Makhni
Journal:  JB JS Open Access       Date:  2019-12-05

10.  Investigating the PROMIS Physical Function and Pain Interference Domains in Elite Athletes.

Authors:  Sreten Franovic; Collin Schlosser; Eric Guo; Luke Hessburg; Noah A Kuhlmann; Kelechi R Okoroha; Eric C Makhni
Journal:  Orthop J Sports Med       Date:  2021-01-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.