Abstract

BACKGROUND AND AIM:: Malposition of peripherally inserted central catheters placed at the bedside is a well-recognized phenomenon. We report the success rate of the placement of peripherally inserted central catheters with ultrasound guidance for tip positioning and describe the knacks and pitfalls.
MATERIALS AND METHODS: : We retrospectively reviewed the medical case charts of 954 patients who received peripherally inserted central catheter procedure. Patient clinical data included success rate of puncture, detection rate of tip malposition with ultrasonography, adjustment rate after X-ray, and success rate of peripherally inserted central catheter placement.
RESULTS: : The success rate of puncture was 100% (954/954). Detection rate of tip malposition with ultrasonography was 82.1% (78/95). The success rate of ultrasound-guided tip navigation was 98.2% (937/954). The success rate of ultrasound-guided tip location was 98.0% (935/954). Adjustment rate after X-ray was 1.79% (17/952). The final success rate of peripherally inserted central catheter placement was 99.8% (952/954).
CONCLUSION: : Ultrasound guidance for puncturing and tip positioning is a promising option for the placement of peripherally inserted central catheters. Ultrasound guidance could dispense with radiation exposure and the transfer of patients to the X-ray department.

Entities:  

Keywords:  Peripherally inserted central venous catheter; tip malposition; ultrasound

Mesh:

Year:  2018        PMID: 29562841     DOI: 10.1177/1129729818765057

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  2 in total

1.  Influence of guide wire removal on tip location in peripherally inserted central catheters (PICCs): a retrospective cross-sectional study.

Authors:  Dan Wang; Fangfang Niu; Huining Gao; Mingkai Yu; Yuhang Li; Liqun Xu; Huizhi Cao; Lili Wang; Jinhua Liu; Xue Ding; Ying Wang; Chen Yu; Huiyan Li; Kaijiang Yu; Changsong Wang
Journal:  BMJ Open       Date:  2019-10-31       Impact factor: 2.692

2.  Relationship between ABO blood group and risk of venous thrombosis in cancer patients with peripherally inserted central catheters: A protocol for systematic review and meta-analysis.

Authors:  Fangjing Liu; Qiang Zhang; Li Rao; Jifang Song
Journal:  Medicine (Baltimore)       Date:  2020-11-06       Impact factor: 1.817

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.