Letter to the editor on "Early intraprosthetic dislocation in dual-mobility implants: a systematic review".

Domenico Tigani1, Jean Louis Prudhon2, Luca Amendola1, Thierry Aslanian3.   

Abstract

Entities:  

Year:  2017        PMID: 29560409      PMCID: PMC5859209          DOI: 10.1016/j.artd.2017.11.004

Source DB:  PubMed          Journal:  Arthroplast Today        ISSN: 2352-3441


× No keyword cloud information.
We read with great interest the article by De Martino et al [1] on early intraprosthetic dislocation (IPD) in dual-mobility cup (DMC). In their discussion, the authors list 3 factors that may be more likely in the early IPD. We know of no evidence supporting the relationship of early IPD with head size of the inner bearing <28 mm or skirted femoral head. On the other hand, we agree that early IPD could be due to a DMC used in an off-label manner to revise an existing total hip arthroplasty, with retention of the femoral stem. We would stress the different reasons for early and late IPD. Late IPD, which occurs after 24 months, is mainly related to the wear of retentive rim in the “third joint” [2]. This leads to failure of the capture mechanism between the mobile polyethylene liner and femoral head [3]. This complication depends on head/neck ratio and also the shape and the roughness of the neck are involved [4]. Femoral necks with an unpolished surface and large diameters should be avoided. For similar reasons, care should be taken to ensure that the base of the Morse taper is fully covered by the femoral head, avoiding skirted femoral heads that can cause impingement with the polyethylene liner. Regarding early IPD, which is rarely described by European authors, it may be considered as a mechanical failure of the retentive rim. Since there is not enough time for the wear process, we think it is due to the specific design of the insert with its capture action. As described by Aslanian [5], the liner's features of different DMC depend on four main factors: first, the diameter and relative position of the retentive ring to limit any harmful contact with the femoral stem; second, the over-covering surface of the head to create an intraprosthetic jump distance; third, the presence of protective beveled edge (chamfers) in contact areas with the prosthetic neck; and fourth, the elasticity of the polyethylene to allow the passage of the head through the retention rim without its plastic deformation leading to the failure of the capture mechanism. For this reason, it would be helpful if these technical data were provided by the manufacturers. This becomes fundamental above all if a DMC is used in an off-label manner to revise an existing total hip arthroplasty with retention of the femoral stem. Finally, De Martino reported that 6 of 15 early IPD (40%) after an attempt of close reduction of the large articulation occurred with modular dual mobility. As previously published by Plummer et al [6], we want to stress that the head diameter and the jump distance are actually reduced by this modularity. We appreciate the authors for attempting to answer an important and controversial topic with a systematic review and for the quality and the originality of their study.
  5 in total

1.  The dual mobility socket concept: experience with 668 cases.

Authors:  Claude Vielpeau; Benoit Lebel; Ludovic Ardouin; Gilles Burdin; Christine Lautridou
Journal:  Int Orthop       Date:  2010-12-24       Impact factor: 3.075

Review 2.  Dual mobility in total hip arthroplasty.

Authors:  Darren R Plummer; Bryan D Haughom; Craig J Della Valle
Journal:  Orthop Clin North Am       Date:  2013-10-01       Impact factor: 2.472

3.  All dual mobility cups are not the same.

Authors:  Thierry Aslanian
Journal:  Int Orthop       Date:  2017-01-18       Impact factor: 3.075

4.  [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

Authors:  F Lecuire; I Benareau; J Rubini; M Basso
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2004-05

5.  Early intraprosthetic dislocation in dual-mobility implants: a systematic review.

Authors:  Ivan De Martino; Rocco D'Apolito; Bradford S Waddell; Alexander S McLawhorn; Peter K Sculco; Thomas P Sculco
Journal:  Arthroplast Today       Date:  2017-02-05
  5 in total
  2 in total

1.  Dual Mobility Cups as the Routine Choice in Total Hip Arthroplasty.

Authors:  Ignacio Aguado-Maestro; Inés de Blas-Sanz; Ana Elena Sanz-Peñas; Silvia Virginia Campesino-Nieto; Jesús Diez-Rodríguez; Sergio Valle-López; Alberto Espinel-Riol; Diego Fernández-Díez; Manuel García-Alonso
Journal:  Medicina (Kaunas)       Date:  2022-04-09       Impact factor: 2.948

2.  Letter to the editor on "Asymptomatic intraprosthetic dual mobility cup dislocation with increased metal ion levels".

Authors:  Emanuela Castiello; Luca Amendola; Paolo Barca; Domenico Tigani; Jacques H Caton; Thomas Neri; Jean Louis Prudhon
Journal:  Arthroplast Today       Date:  2020-02-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.