Extra-small dual-lumen micro-balloon catheters can improve endovascular embolization: an experimental in vivo and in vitro study.

Dominik F Vollherbst1,2, Ruth Otto1, Thuy D Do2, Andreas von Deimling3, Hans U Kauczor2, Martin Bendszus1, Christof M Sommer2,4, Markus A Möhlenbruch1.   

Abstract

BACKGROUND: The embolization technique can have significant impact on the success of endovascular embolization.
OBJECTIVE: To evaluate the feasibility, embolization characteristics, and embolization extent with a newly developed extra-small micro-balloon catheter in an in vivo and in an in vitro embolization model in comparison with standard microcatheter embolizations.
MATERIALS AND METHODS: Twenty-eight embolization procedures were performed in the porcine rete mirabile (RM) and in an in vitro embolization model, using either an extra-small (distal outer diameter 1.6 F) dual-lumen micro-balloon catheter or a standard microcatheter. Precipitating hydrophobic injectable liquid (PHIL) was used as embolic agent. Procedure times, number of injections, required volume of embolic agent, and embolization extent (percentage of embolized RM in postinterventional X-ray scans or number of filled sections of the in vitro model) were assessed. Histopathological analyses were performed.
RESULTS: Total procedure time was significantly shorter (in vivo: 123 s vs 615 s (medians), P=0.001; in vitro: 180 s vs 496 s (medians), P=0.001), number of reflux events was significantly lower (in vivo: 0 vs 9 (medians), P=0.001; in vitro: 0 vs 3 (medians), P=0.001), and embolization extent was significantly higher (in vivo: 96.9% vs 65.6% (medians), P=0.011; in vitro: 26 vs 18 filled sections (medians); P=0.041) for the micro-balloon catheter groups. There was antegrade movement of the PHIL cast after balloon deflation in one in vitro embolization procedure and spontaneous balloon deflation with subsequent reflux in one in vivo embolization procedure.
CONCLUSION: Extra-small dual-lumen micro-balloon catheters can improve endovascular embolization in comparison with standard microcatheter embolization. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  arteriovenous malformation; balloon; catheter; fistula; liquid embolic material

Mesh:

Year:  2018        PMID: 29555871     DOI: 10.1136/neurintsurg-2018-013752

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  6 in total

1.  Intermixed Dimethyl-Sulfoxide-Based Nonadhesive Liquid Embolic Agents Delivered Serially via the Same Microcatheter for Cerebral AVM Treatment.

Authors:  A Sirakov; K Minkin; S Sirakov
Journal:  AJNR Am J Neuroradiol       Date:  2020-03-12       Impact factor: 3.825

Review 2.  Endovascular Management of Intracranial Dural Arteriovenous Fistulas: Transarterial Approach.

Authors:  K D Bhatia; H Lee; H Kortman; J Klostranec; W Guest; T Wälchli; I Radovanovic; T Krings; V M Pereira
Journal:  AJNR Am J Neuroradiol       Date:  2021-10-07       Impact factor: 3.825

3.  Initial experience with the Scepter Mini catheter for the embolization of vascular malformations in the pediatric population.

Authors:  Stavros Matsoukas; Devin Bageac; Kurt Yaeger; Alejandro Berenstein; Johanna T Fifi; Tomoyoshi Shigematsu
Journal:  Neuroradiol J       Date:  2021-10-05

4.  Single institution early clinical experience with the Scepter Mini balloon catheter.

Authors:  Timothy G White; Kevin A Shah; Justin Turpin; Amir R Dehdashti; Thomas Link; Jeffrey M Katz; Henry H Woo
Journal:  Neuroradiol J       Date:  2021-05-20

5.  Treatment of a central venous perforation caused by dialysis intubation using coils and cyanoacrylate glue: A case report.

Authors:  Chun-Ze Zhou; Kai-Cai Liu; Peng Wang; Wei Ren; Wei-Fu Lv
Journal:  Exp Ther Med       Date:  2019-08-20       Impact factor: 2.447

6.  Immobilized thrombin on X-ray radiopaque polyvinyl alcohol/chitosan embolic microspheres for precise localization and topical blood coagulation.

Authors:  Xiaohong Li; Xiongfa Ji; Kun Chen; Muhammad Wajid Ullah; Basen Li; Jiameng Cao; Lin Xiao; Jun Xiao; Guang Yang
Journal:  Bioact Mater       Date:  2021-01-12
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.