Intraoperative Nerve Monitoring in Robotic-Assisted Resection Of Presacral Ganglioneuroma: Operative Technique.

Tomas Garzon-Muvdi1, Allan Belzberg1, Mohamad E Allaf2, Jean-Paul Wolinsky1.   

Abstract

BACKGROUND: Robotic-assisted techniques have been implemented in the surgical treatment of tumors in the pelvis, abdomen, and thorax. In pelvic tumors, robotic-assisted techniques evade the need for sizable surgical exposure, but make stimulation of the nerves of the sacral plexus very difficult.
OBJECTIVE: To describe how laparoscopic robotic-assisted surgery can couple with tools such as the nerve stimulator to aid in the resection of presacral masses emanating from the neural elements and potentially improve neurological outcome by preventing inadvertent injury to involved nerves.
METHODS: A patient with a large presacral ganglioneuroma underwent resection using the DaVinci system (Intuitive Surgical, Sunnyvale, California) for robotic assistance. A nerve stimulator was coupled to the bipolar cautery instrument of the DaVinci robot to define the presence of functional nerves in the surroundings of the tumor.
RESULTS: By coupling a nerve stimulator to the bipolar cautery instrument of the DaVinci robot (Intuitive Surgical), it was possible to identify important neural structures in close proximity to the tumor. After identifying functional nerves, the surgeon was able to preserve them and preserve neurological function avoiding motor dysfunction.
CONCLUSION: The use of a nerve stimulator coupled to the bipolar cautery instrument of the DaVinci robot (Intuitive Surgical) during laparoscopic, robotic-assisted surgery for resection of presacral masses is safe and feasible. In addition to the preoperative evaluation, intraoperative monitoring and stimulation of nerves in close proximity to the tumor and also exiting through neural foramina involved by the tumor allowed the surgeon to understand the anatomy and preserve neurological function while obtaining optimal surgical resection.

Entities:  

Mesh:

Year:  2019        PMID: 29554323     DOI: 10.1093/ons/opy040

Source DB:  PubMed          Journal:  Oper Neurosurg (Hagerstown)        ISSN: 2332-4252            Impact factor:   2.703


  2 in total

Review 1.  Robotic Nerve Sheath Tumor Resection With Intraoperative Neuromonitoring: Case Series and Systematic Review.

Authors:  Brian P Curry; Reinier Alvarez; Brigitte C Widemann; Matthew Johnson; Piyush K Agarwal; Tanya Lehky; Vladimir Valera; Prashant Chittiboina
Journal:  Oper Neurosurg (Hagerstown)       Date:  2022-02-01       Impact factor: 2.817

2.  Application of the da Vinci surgical robot system in presacral nerve sheath tumor treatment.

Authors:  Feifei Pu; Zhicai Zhang; Zhaohui Chen; Kailin Cai; Baichuan Wang; Qiang Wu; Deyao Shi; Jianxiang Liu; Zengwu Shao
Journal:  Oncol Lett       Date:  2020-08-19       Impact factor: 2.967

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.