Literature DB >> 29552513

State-of the-art review on the renal and visceral protection during open thoracoabdominal aortic aneurysm repair.

Karl Waked1, Marc Schepens1.   

Abstract

During open thoracoabdominal aortic aneurysm repair (OTAAAR), there is an inevitable organ ischemic period that occurs when the abdominal arteries are being reattached to the aortic graft. Despite various protective techniques, the incidence of renal and visceral complications remains substantial. This state-of-the-art review gives an overview of the current and most evidence-based organ protection methods during OTAAAR, based on the most recent publications and personal experience. An electronic search was performed in four medical databases, using the following MeSH terms: thoracoabdominal aneurysm, TAAAR, visceral protection, renal protection, kidney, perfusion, and intestines. Every publication type was considered. The literature search was ended on August 31st, 2017. The left heart bypass (LHB) is currently the most frequent adjunct to provide distal aortic perfusion (DAP) during aortic clamping. Together with systemic hypothermia, it forms the cornerstone in organ protection during aortic clamping. Further renal protection can be obtained by selective renal perfusion (SRP) with cold blood or cold crystalloid solution, the latter enriched with mannitol. The perfusion should be administered in a volume- and pressure-controlled way and, if possible, by use of a pulsatile pump. Selective visceral perfusion (SVP) is not routinely used, as it does not provide adequate blood flow for visceral protection. The best way to protect the intestines is by minimizing the ischemic time. The preservation of renal and visceral function after OTAAAR can only be obtained with specific strategies before, during, and after the operation. This involves a series of measures, including selective digestive decontamination (SDD), avoidance of nephrotoxic drugs, minimizing the renal and intestinal ischemic time, systemic cooling, avoidance of hemodynamic instability, and regional protective perfusion of the kidneys. Future innovations in catheters, cardiac bypass flow types, mechanical components, hybrid vascular grafts, and pharmaceutical protection measures will hopefully further reduce organ complications.

Entities:  

Keywords:  Thoracoabdominal aortic aneurysm repair; renal protection; selective organ perfusion; visceral protection

Year:  2018        PMID: 29552513      PMCID: PMC5847903          DOI: 10.21037/jovs.2018.01.12

Source DB:  PubMed          Journal:  J Vis Surg        ISSN: 2221-2965


  91 in total

Review 1.  Outcomes in open repair of the thoracic and thoracoabdominal aorta.

Authors:  Charles Acher; Martha Wynn
Journal:  J Vasc Surg       Date:  2010-08-14       Impact factor: 4.268

2.  Patient selection for open thoracoabdominal aneurysm repair.

Authors:  Marc A A M Schepens; Filip G J Van den Brande
Journal:  Ann Cardiothorac Surg       Date:  2012-09

3.  Treatment of sepsis.

Authors:  Hendrick K van Saene; Hendrick K van Saeene; Luciano Silvestri; Nia Taylor; Andy Petros; Julian Bion
Journal:  Lancet Infect Dis       Date:  2012-09-24       Impact factor: 25.071

4.  Stenting of the renal artery to improve renal function prior to thoracoabdominal aneurysm repair.

Authors:  T M Sullivan; N R Hertzer
Journal:  J Endovasc Surg       Date:  1998-02

5.  Optimal end-organ protection for thoracic and thoracoabdominal aortic aneurysm repair using deep hypothermic circulatory arrest.

Authors:  John W Fehrenbacher; David W Hart; Erica Huddleston; Harry Siderys; Camille Rice
Journal:  Ann Thorac Surg       Date:  2007-03       Impact factor: 4.330

6.  Open repair of descending thoracic and thoracoabdominal aortic aneurysms in patients with preoperative renal failure.

Authors:  Leonard N Girardi; Lucas B Ohmes; Christopher Lau; Antonino Di Franco; Ivancarmine Gambardella; Mohamed Elsayed; Fawad Hameedi; Monica Munjal; Mario Gaudino
Journal:  Eur J Cardiothorac Surg       Date:  2017-05-01       Impact factor: 4.191

7.  Introduction of adjuncts and their influence on changing results in 402 consecutive thoracoabdominal aortic aneurysm repairs.

Authors:  Marc Schepens; Karl Dossche; Wim Morshuis; Robin Heijmen; Eric van Dongen; Huub Ter Beek; Hans Kelder; Eduard Boezeman
Journal:  Eur J Cardiothorac Surg       Date:  2004-05       Impact factor: 4.191

Review 8.  Tips for successful outcomes for descending thoracic and thoracoabdominal aortic aneurysm procedures.

Authors:  Joseph S Coselli; Scott A LeMaire
Journal:  Semin Vasc Surg       Date:  2008-03       Impact factor: 1.000

Review 9.  Contemporary strategies to preserve renal function during cardiac and vascular surgery.

Authors:  Roy Sheinbaum; Craig Ignacio; Hazim J Safi; Anthony Estrera
Journal:  Rev Cardiovasc Med       Date:  2003       Impact factor: 2.930

10.  Appraisal of adjuncts to prevent acute renal failure after surgery on the thoracic or thoracoabdominal aorta.

Authors:  L G Svensson; J S Coselli; H J Safi; K R Hess; E S Crawford
Journal:  J Vasc Surg       Date:  1989-09       Impact factor: 4.268

View more
  4 in total

1.  Visceral and renal protection in thoracoabdominal aortic surgery.

Authors:  Cuddalore Sadasivan Vijayashankar; George Jose Valooran
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-01-20

2.  Extensive complex thoracoabdominal aortic aneurysm salvaged by surgical graft providing landing zone for endovascular graft: A case report.

Authors:  Albert Youngwoo Jang; Pyung Chun Oh; Jin Mo Kang; Chul Hyun Park; Woong Chol Kang
Journal:  World J Clin Cases       Date:  2022-05-26       Impact factor: 1.534

Review 3.  Selective Intestinal Decontamination as a Method for Preventing Infectious Complications (Review).

Authors:  A L Barsuk; E S Nekaeva; L V Lovtsova; A L Urakov
Journal:  Sovrem Tekhnologii Med       Date:  2020-12-28

4.  Open repair of a Coxiella burnetii-associated abdominal aortic endovascular stent graft infection with a cryopreserved allograft using visceral artery pump perfusion.

Authors:  Hoi Yee Annie Lo; Michael Cheng; Linda Chun; Kevin Patel; Wesley Lew
Journal:  J Vasc Surg Cases Innov Tech       Date:  2022-01-05
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.