Literature DB >> 29550001

Interobserver and Intraobserver Reliability of Cone-beam Computed Tomography in Identification of Apical Periodontitis.

Cole W Barnett1, Gerald N Glickman1, Mikhail Umorin2, Poorya Jalali3.   

Abstract

INTRODUCTION: Accurate radiographic interpretation is of the utmost importance in the diagnosis and treatment of patients. Previous studies have indicated subjectivity in the radiographic interpretation of periapical tissues irrespective of using conventional radiography, digital radiography, or cone-beam computed tomographic (CBCT) imaging. No studies to date have evaluated the reliability of the interpretation of periapical tissues based on the size of periapical radiolucency (PAR). The purpose of this study was to assess the interobserver and intraobserver reliability of CBCT interpretation by observers from different specialties and different levels of experience when identifying PARs of various sizes.
METHODS: Limited field of view CBCT scans were selected such that a variety of PARs with various sizes were included. Six observers with different levels of experience and fields of specialty evaluated periradicular tissues of 28 roots on the CBCT scans at 3 separate sittings each a month apart.
RESULTS: The overall Fleiss kappa coefficient for interobserver reliability and intraobserver reliability was 0.88 and 0.85; the larger the PAR, the more reliable the radiographic interpretation. Increased experience level improved the intraobserver reliability.
CONCLUSIONS: CBCT imaging appears to be a reliable method for the interpretation of PAR. The larger the PAR is the more reliable the radiographic interpretation.
Copyright © 2018 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Cone-beam computed tomography; periapical radiolucency; reliability

Mesh:

Year:  2018        PMID: 29550001     DOI: 10.1016/j.joen.2017.12.022

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  2 in total

1.  Measuring agreement among experts in classifying camera images of similar species.

Authors:  T J Gooliaff; Karen E Hodges
Journal:  Ecol Evol       Date:  2018-10-30       Impact factor: 2.912

2.  Interobserver and intraobserver variability in the radiological assessment of sialolithiasis using cone beam computed tomography.

Authors:  L-J Beumer; E-H van der Meij; J-I Kamstra; J-G de Visscher
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2022-01-01
  2 in total