Literature DB >> 29543078

Comparison of diagnostic efficacy between CLE, tissue sampling, and CLE combined with tissue sampling for undetermined pancreaticobiliary strictures: a meta-analysis.

Ya-Dong Gao1, Ya-Wei Qu2, Hai-Feng Liu1.   

Abstract

OBJECTIVE: The accurate diagnosis of undetermined pancreaticobiliary strictures remains challenging. Current ERCP-guided tissue sampling methods are of low sensitivity. Confocal laser endomicroscopy (CLE) is a new procedure and allows real optical biopsies that may improve the diagnosis of undetermined pancreaticobiliary strictures. The aim of this meta-analysis was to determine the diagnostic yield of CLE, tissue sampling, and CLE combined with tissue sampling for undetermined pancreaticobiliary strictures.
METHOD: Pubmed, Embase, and the Cochrane Library database were reviewed for relevant studies. Pooled estimates of sensitivity and specificity with 95% confidence intervals (CIs) were calculated using the random-effects meta-analysis model. The summary receiver-operating characteristic (SROC) curve was constructed, and the area under the receiver operating characteristic curve (AUC) was calculated.
RESULTS: Twelve studies involving 591 patients were enrolled in our analysis. The overall sensitivity and the specificity estimate of CLE for discriminating benign and malignant pancreaticobiliary strictures were 87% (95%CI, 83-91%) and 76% (95%CI, 70-81%), respectively. The AUC to assess the diagnostic efficacy was 0.8705. For tissue sampling, the overall sensitivity and the specificity estimate were 64% (95%CI, 57-70%) and 94% (95%CI, 90-97%), respectively. The AUC to assess the diagnostic efficacy was 0.8040. A combination of both methods increased the sensitivity (93%; 95%CI, 88-96%) with a specificity of 82% (95%CI, 74-89%). The AUC to assess the diagnostic efficacy was 0.9377. There was no publication bias by Deeks' Funnel Plot with p = .936.
CONCLUSIONS: Compared with tissue sampling, CLE may increase the sensitivity for the diagnosis of malignant pancreaticobiliary strictures. A combination of both can effectively diagnose malignant pancreaticobiliary strictures.

Entities:  

Keywords:  Confocal laser endomicroscopy; meta-analysis; pancreaticobiliary strictures; sensitivity; tissue sampling

Mesh:

Year:  2018        PMID: 29543078     DOI: 10.1080/00365521.2018.1448435

Source DB:  PubMed          Journal:  Scand J Gastroenterol        ISSN: 0036-5521            Impact factor:   2.423


  4 in total

Review 1.  Confocal laser endomicroscopy in gastro-intestinal endoscopy: technical aspects and clinical applications.

Authors:  Nastazja Dagny Pilonis; Wladyslaw Januszewicz; Massimiliano di Pietro
Journal:  Transl Gastroenterol Hepatol       Date:  2022-01-25

Review 2.  Challenging biliary strictures: pathophysiological features, differential diagnosis, diagnostic algorithms, and new clinically relevant biomarkers - part 1.

Authors:  Jean-Marc Dumonceau; Myriam Delhaye; Nicolas Charette; Annarita Farina
Journal:  Therap Adv Gastroenterol       Date:  2020-06-16       Impact factor: 4.409

3.  Confocal Laser Endomicroscopy in the Diagnosis of Biliary and Pancreatic Disorders: A Systematic Analysis.

Authors:  Do Han Kim; Somashekar G Krishna; Emmanuel Coronel; Paul T Kröner; Herbert C Wolfsen; Michael B Wallace; Juan E Corral
Journal:  Clin Endosc       Date:  2021-11-29

Review 4.  Endoscopic Evaluation of Biliary Strictures: Current and Emerging Techniques.

Authors:  Roy Huynh; Corinne Owers; Christopher Pinto; Thuy-My Nguyen; Titus Kwok
Journal:  Clin Endosc       Date:  2021-05-27
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.