Thermafil: A New Clinical Approach Due to New Dimensional Evaluations.

G Vittoria1, G Pantaleo1, A Blasi1, G Spagnuolo1, A Iandolo1, M Amato2.   

Abstract

BACKGROUND: There are a lot of techniques to obturate the root canals, but lateral condensation of gutta-percha is the most used one. An important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between different carriers. It is demonstrated that the error margin of gutta-percha is 0.5% and is 0.2% for metal files (ISO standards).
OBJECTIVE: The aim of this study was to evaluate the real dimensions of thermafil plastic carriers observed by the stereo microscope measuring the dimensional discrepancy between them.
METHODS: For this study, 80 new thermafil (Dentsply Maillefer) have been selected. 40 thermafil 0.25 and 40 thermafil 0.30. Through 60X stereo microscope, the dimensions of the plastic carrier tips have been measured. The dimensions of the plastic carrier were also measured after a heating cycle. ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used to observe the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X.
RESULTS: A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 were assumed to be statistically significant.
CONCLUSION: The samples we measured showed a mean value of the diameters in Thermafil 25 that was 0.27 mm, for Thermafil 30 the mean value was 0.33 mm.We have measured a dimensional variable of 8% in the 25 group while in group 30 the maximum possible variation found was 4%, that's why we propose a new protocol of obturation with thermafil. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions.

Entities:  

Keywords:  Endodontic obturation; Gutta-percha; NiTi rotary system; Stereo microscope; Thermafil; Zetaline stereo evolution

Year:  2018        PMID: 29541263      PMCID: PMC5838644          DOI: 10.2174/1874210601812010173

Source DB:  PubMed          Journal:  Open Dent J        ISSN: 1874-2106


INTRODUCTION

Many techniques have been developed to obturate the root canals, but lateral condensation of gutta-percha has been the widely used technique [1-3]. Recently, the manufacturers have introduced their individual tapered gutta-percha master cones to match the taper and apical sizes of the canals prepared with the respective NiTi rotary system claiming that the matched taper points can fill tapered canals effectively since they correspond to canal shapes created by instruments of similar taper [4]. Manufacturers also recommend obturation of the root canals prepared with NiTi rotary systems by using their respective thermoplasticized gutta-percha coated carrier systems. Obturators are designed to correspond to the ISO standard file sizes and variable tapered NiTi rotary files. It was stated that these techniques can produce a homogenous mass in the root canal with a better gutta-percha-to-sealer ratio than that achieved with cold lateral condensation [5, 6]. Thermafil technique was introduced by Ben Johnson in 1978 and in the early 1990s it was introduced into the market as a K-File covered by gutta-percha that was inserted into the canal after bunsen flame heating [7]. Thermafil is a gold standard technique in case of severe curves, double curves, narrow canals and long canals [2, 8, 9] The current configuration of Thermafil includes a central radiopaque plastic core (carrier) surrounded by a gutta-percha layer that will be heated in an electric oven to ensure thermoplasticization. Thermafil obturators are available in 17 sizes, from 0.20 to 1.40 mm of tip diameter, with carrier taper of about 4%. Thermafil gutta-percha covers the carrier for about 16 mm [10]. For the selection of the correct obturator are available Ni-Ti verifiers with a diameter of 0.20 to 0.90 mm [11]. Some authors [12, 13] propose to use Thermafil plastic carrier from which the gutta percha has been removed (denudate carrier) instead of Ni-Ti verifiers, as the carrier reproduces the conditions occurring during filling operations better than the Ni-Ti verifier, so it is suggested to clinicians to denudate a series of carriers that are used only as “verifiers”, and then choose a corresponding obturator to seal the canal. Pasqualini et al. [14] demonstrated in vitro that there is less apical infiltration selecting the denuded carrier reaching 0.5 mm from the apex that engage against the canal walls instead of selecting an obturator referring only to the correspondence between the apical final shaping diameter and the obturator size. Another important aspect of thermafil is the error margin tolerated by the manufacturer in the production of plastic carriers. In literature, there is no evidence about discrepancy percentage between the different carriers. In the literature, it is demonstrated that the error margin of guttapercha is 0.5% and is 0.2% for metal files (ISO standards) [8, 15]. The aim of this study was to evaluate the real thermafil plastic carriers dimensions observed by the stereo microscope measuring the dimensional discrepancy between them.

MATERIALS AND METHODS

A sample of 80 new thermafil (Dentsply Maillefer) was selected, 40 with 0.25 diameter and 40 with 0.30 diameter. Four groups were created for the study: Group 1 composed by 40 plastic carriers with 0.25 diameter; Group 2 composed by 40 plastic carriers with 0.30 diameter; Group 3 composed by 20 preheated 0.25 plastic carriers; Group 4 composed by 20 preheated 0.30 plastic carriers. In all groups, thermafil has been denudated by gutta-percha by a single operator, using fingers and making sure not to apply strong pressures. No sharp tools were used to avoid deformation of plastic carriers. After measurements, the carriers of group 3 and 4 were covered again with gutta-percha and heated using the thermaprep plus oven (Dentsply Maillefer) set to 20-25 for group 3 (almost 20 seconds heating) and set to 30-60 for group 4 (almost 41 seconds heating). After 30 minutes of cooling carriers were denudated again by the same operator. Before measurements of all plasticized carriers, they were observed at 60X to evaluate the presence of guttapercha traces. Any trace has been removed before proceeding to measurements (Fig. ). ZL GAL 11TUSM (Zetaline stereo evolution) microscope was used for observation of the samples. Measurements were made through a dedicated software (Image Focus). All samples were analysed at 60X. Samples were all placed in the same position before microscope analysis. Measurements were taken only when all the plastic carrier tip surface was focused. As the plastic carrier tips were not perfectly circular, two measurements were taken for each sample, horizontal and vertical diameter. To calculate the dimensional variability, we needed a reference value of the plastic core dimension. In literature or in the manufacturer’s indications this value is missing (the size of plastic core of a thermafil 25 and the size of the plastic core of thermafil 30). That’s why we compared our measurements not only with our samples media values, but also with an ideal value deduced by 2 literature statements: Gutta-percha exceeds the carrier of about 1mm Thermafil has a conicity of about 4%. The ideal reference values which have been arbitrarily attributed, will therefore be 0.29 for Thermafil 25 and 0.34 for thermafil 30.

Statistical Analysis

First of all the two ideal reference values of diameters (0,29 mm and 0,34 mm) were transformed in areas: for each group an ideal area has been calculated, assuming a perfectly circular shape. A tolerance of 0.02 mm for the diameters has been accepted, the ideal areas were 0.066 ± 0.009 mm2 for Group 1 and 0.091 ± 0.011 mm2 for Group 2. Then the tip area for each single plastic carrier has been calculated using the following formula for the ellipse area: (vertical axis / 2 x horizontal axis / 2 xπ) and the results were compared with the ideal values. The same was repeated for carriers after heating. A non-parametric paired test (Wilcoxon test) was used to compare baseline and after heating values; p-values ≤ 0.05 was assumed to be statistically significant.

RESULTS

In Group 1, only 11 samples showed an area within the ideal range (metal tolerance), while 27 had a smaller area and 2 a larger one. In Group 2, 34 samples had correspondence to the ideal range while 6 had a smaller area; no sample showed a wider area than the ideal one. After heating, the areas were statistically wider than baseline in both groups (p = 0.0001 and p = 0.002 respectively), but this variation did not significantly affect the clinical appearance. So, in Group 1, only a sample after heating increased its area to fit the ideal parameters, while no variations in group 2 were reported. The mean value of the diameters in Group 1 was 0.27 mm with a standard deviation of 0.02 (0.01); in group 2 the mean value was 0.33mm with a standard deviation of 0.01; in group 3 the mean value was 0.27 mm (0.26) with a standard deviation of 0.01 (0.02); in group 4 the mean value was 0.33mm with a standard deviation of 0.01. The diameter (assuming an ideal circular shape) of most far from the media samples in the group 1 and 2 has been calculated, the maximum diameter in group 1 was 0.32 mm and the minimum 0.24 mm; in group 2 the maximum diameter was 0.34 mm and the minimum 0.30 mm (Figs. -).

DISCUSSION

Thermafil technique is an extremely simple and fast technique, gold standard in curved and long canals, it is the only technique with apex closed by thermo plasticized gutta-percha for sure [8, 16]. Thermafil technique showed significantly higher percentage of gutta-percha-filled area than the lateral condensation technique at all segments of the root canals instrumented with hand files [9-17]. This finding corroborates with the findings of Samadi and De-Deus [18, 19] who reported the same results for Thermafil group in comparison with the lateral condensation in the cross-sectional root canal areas instrumented with hand files. Among the various indications in literature about the apical control of gutta-percha with the Thermafil technique, the most reported is to cut 1mm of gutta-percha that protrudes from the thermafil carrier to reduce its apical excesses [14, 20-22]. There is no scientific study that demonstrates this cut really avoids overfillings. We have scientific evidence instead that the apical control of plastic carriers affects the filling quality. Based on the results highlighted in this study, a new protocol of carrier selection and management for root canal filling is proposed by Vittoria et al. Due to the longitudinal slot on the carrier, it is essential to have a mark which allows to find the correct position of the gutta-percha compared to the carrier at the time of covering (Fig. ). If this position is not found, the gutta-percha breaks down when it is reaffixed to the carrier. Such marking could be obtained with sterile dermatological marker or with a blade incision. Then the Thermafil corresponding to the diameter measured at LL (or 1 mm from the LL) is selected and gently cleaved from the gutta-percha, using two fingers with sterile gloves. Any gutta-percha residue on the carrier must be carefully removed to prevent it from dropping and blocking the canal during the test. The carrier is tested at 1 mm from the working length with pressure; if the carrier should slide more apically it would be controlled and modified by a scalpel, shortening it over the LL +1 mm. The so modified carrier must reach 1mm from the working length without being able to go even further if pushed into the canal,we also suggest an x-ray control. By using the marker as a guide, gutta-percha is gently repositioned on the carrier, and then the excess of gutta is removed with a scalpel until we have 1 mm or 1.5 mm of gutta exceeding the shortened carrier. A thermafil obturator was then created, individualized to the canal that has to be filled. The tested carrier in the canal is the same that will close it removing the risk of dimensional variations and cross-infection. The proposed modified technique allows to accurately determine the position and diameter of the carrier within the canal because it has been tested inside it, so the technique can be controlled also with large apex, removing the risk of cross-infection, it gives us the possibility to adapt a thermafil blister to different sizes, it removes the dimensional variables that could be encountered with classical technique, making apical control more predictable. The plastic core is the only part of the Thermafil system that the clinician can control as the guttaperca became fluid. We've found in literature [14] a relation between apical position of the plastic core and sealing ability of the system. We've also found a lack in literature of measurement of these plastic cores. Our results showed that a consideration about that in clinical protocols should be done. The disadvantage is for large apical diameters where carrier could be too shortened not reaching the working length anymore. The authors of this study therefore propose separate blisters with the only plastic carriers, or better in cross-linked gutta-percha, to be able to try in the canal to choose that one that best suits and possibly modify it, and blisters with gutta-percha that could be attached to the selected carrier.

CONCLUSION

The mean value of the diameters in Group 1 and 3 (Thermafil 25) was 0.27 mm in group 2 and 4 (Thermafil 30) the mean value was 0.33 mm. Within the limitations of this study, from a clinical point of view, and regarding only this sample, in the most unfortunate hypothesis, for thermafil 25 if we select the smallest carrier we measured as verifier (0,24 mm) and we obture canal with the bigger one (0,32 mm) we will have a dimensional variable of 8% and a certain canal subtraction, in the case of Thermafil 30 the maximum possible variation found is 4%. We can also conclude that a single heating process does not affect clinically the plastic carrier dimensions.
  20 in total

Review 1.  Carrier-based root canal filling materials: a literature review.

Authors:  Ahmed Mubarak Al-Kahtani
Journal:  J Contemp Dent Pract       Date:  2013-07-01

Review 2.  An In-Vitro Evaluation and Comparison of Apical Sealing Ability of Three Different Obturation Technique - Lateral Condensation, Obtura II, and Thermafil.

Authors:  Samson Emmanuel; Kulkarni Shantaram; Kumar C Sushil; Likhitkar Manoj
Journal:  J Int Oral Health       Date:  2013-04

3.  Volumetric analysis of root filling with cold lateral compaction, Obtura II, Thermafil, and Calamus using spiral computerized tomography: An In vitro Study.

Authors:  Divya Jindal; Medhavi Sharma; Deepak Raisingani; Anupama Swarnkar; Mridu Pant; Rachit Mathur
Journal:  Indian J Dent Res       Date:  2017 Mar-Apr

4.  Time required to remove guttacore, thermafil plus, and thermoplasticized gutta-percha from moderately curved root canals with protaper files.

Authors:  Robert T Beasley; Anne E Williamson; Bruce C Justman; Fang Qian
Journal:  J Endod       Date:  2012-11-13       Impact factor: 4.171

5.  Adaptation of thermafil components to canal walls.

Authors:  B Johnson; D Lasater
Journal:  J Endod       Date:  1993-06       Impact factor: 4.171

6.  Apical sealing ability of metal versus plastic carrier Thermafil obturators.

Authors:  D S Clark; M E ElDeeb
Journal:  J Endod       Date:  1993-01       Impact factor: 4.171

Review 7.  Review of a new root canal obturation technique.

Authors:  K Gulabivala; S F Leung
Journal:  Dent Update       Date:  1994-03

8.  Evaluation and comparison of sealing ability of three different obturation techniques - Lateral condensation, Obtura II, and GuttaFlow: An in vitro study.

Authors:  Kavitha Anantula; Anil Kumar Ganta
Journal:  J Conserv Dent       Date:  2011-01

9.  Temperature Profiles Along the Root with Gutta-percha Warmed through Different Heat Sources.

Authors:  Michele Simeone; Roberto De Santis; Gianluca Ametrano; Davide Prisco; Marino Borrelli; Sergio Paduano; Francesco Riccitiello; Gianrico Spagnuolo
Journal:  Open Dent J       Date:  2014-12-29

10.  Interface Between MTA and Dental Bonding Agents: Scanning Electron Microscope Evaluation.

Authors:  Gabriele Cervino; Luca Fiorillo; Gianrico Spagnuolo; Ennio Bramanti; Luigi Laino; Floriana Lauritano; Marco Cicciù
Journal:  J Int Soc Prev Community Dent       Date:  2017-02-21
View more
  1 in total

1.  Comparison of Two Root Canal Filling Techniques: Obturation with Guttacore Carrier Based System and Obturation with Guttaflow2 Fluid Gutta-Percha.

Authors:  Guido Migliau; Gaspare Palaia; Daniele Pergolini; Tommaso Guglielmelli; Roberta Fascetti; Afrah Sofan; Alessandro Del Vecchio; Umberto Romeo
Journal:  Dent J (Basel)       Date:  2022-04-15
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.