Continuous measurement of pulmonary blood flow using a retractable pulsed Doppler probe.

C L Lucas, G W Henry, B A Keagy, E Criado, J I Ferreiro, B Ha, M D Baudino, B R Wilcox.   

Abstract

The feasibility of measuring pulmonary blood flow (PAQ) continuously using a removable, extraluminal 20 MHz pulsed Doppler probe, which has been used successfully to measure aortic blood flow, was assessed in seven anesthetized mongrel dogs. Simultaneous recordings were made from the Doppler probe (range-gated 5-6 mm from the anterior wall of the main pulmonary artery) and an electromagnetic flow probe (encircling the aorta) over cardiac outputs (CO) ranging from 0.2 to 5.5 L/min. Assuming a flat velocity profile and a fixed cross-sectional area, PAQ was initially calculated as the product of area and mean velocity. Regression analyses (PAQ = a + b X CO) indicated good intraanimal linear correlations in six animals (r greater than or equal to 0.84) and no correlation in one animal (r = 0.003); however, PAQ was consistently higher than CO and interanimal variability was marked, as suggested by large deviations in mean intercept and slope values (a = 1.67 +/- 1.09 L/min and b = 0.70 +/- 0.33). Results improved (r greater than or equal to 0.79 in all animals, a = 0.47 +/- 0.52 L/min, and b = 0.77 +/- 0.21) when the method to estimate PAQ was altered to assume that the starting cross-sectional area was the area that would make baseline PAQ and CO agree, and that the area during each subsequent CO level changed as a function of pulmonary artery pressure and an estimate of pulmonary artery compliance. Results of this study imply that it will be more difficult to use this Doppler probe to monitor CO from the pulmonary artery than it was from the aorta due to the elliptical, more compliant pulmonary vessel walls and the irregular pulmonary artery velocity profile.

Entities:  

Mesh:

Year:  1987        PMID: 2953906     DOI: 10.7863/jum.1987.6.4.181

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Pulmonary blood velocity profile variability in open-chest dogs: influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination.

Authors:  C L Lucas; G W Henry; J I Ferreiro; B Ha; B A Keagy; B R Wilcox
Journal:  Heart Vessels       Date:  1988       Impact factor: 2.037

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.