Literature DB >> 29537324

Long-term outcome after surgical repair of pelvic organ prolapse with Elevate Prolapse Repair System.

Danilo Italo Pio Buca1, Marco Liberati1, Eleonora Falò1, Martina Leombroni1, Maria Di Giminiani2, Marta Di Nicola3, Alessandro Santarelli1, Franco Frondaroli1, Francesco Fanfani4.   

Abstract

Female pelvic organ prolapse (POP) is a common condition and the correction of prolapse remains a major challenge for the surgical community. A retrospective study of women with POP undergoing pelvic reconstructive surgery with the Elevate System followed-up for 48 months. A total of 138 women with POP were included in the study. We observed an objective cure rate of 94.9% for the anterior wall after 4 years' follow-up. The subjective cure rate was 97.1%. Improvement in the urinary symptoms was seen after the surgery: the number of asymptomatic patients increased from 14.5 to 77% after the 4 years of follow-up. We reported no cases of bleeding, haematoma, mesh infection and bowel injury, while we had four cases of bladder injury and one case of sepsis. The mesh extrusion rate was 7.3%, all cases interested the anterior compartment. Postoperative dyspareunia and pelvic pain were rare. In this cohort, the Elevate Prolapse Repair System was associated with excellent long-term results, for both anatomical corrections of prolapse, with a high objective and subjective cure rate and a functional urinary outcome. Impact statement What is already known on this subject? Female pelvic organ prolapse is a common condition and the correction of prolapse remains a major challenge for the surgical community. The optimal treatment of POP has still to be determined. What do the results of this study add? The findings from this study shows that the Elevate Prolapse Repair System had high anatomic results associated with a good durability, low morbidity and excellent subjective outcome. To the best of our knowledge, this is the first study that reports a follow-up up to 48 months. What are the implications of these findings for clinical practice and/or further research? The Elevate Prolapse Repair System was associated with excellent long terms results in terms of safety, durability and tolerability during the 4 years' follow-up. Despite the fact that the Elevate kit produced by AMS was withdrawn from the market and it is no longer available, we believe that it is helpful to have data about the outcomes of a transvaginal mesh implant.

Entities:  

Keywords:  Elevate repair system; POP-Q; Pelvic organ prolapse; follow-up; polypropylene mesh

Mesh:

Year:  2018        PMID: 29537324     DOI: 10.1080/01443615.2017.1419462

Source DB:  PubMed          Journal:  J Obstet Gynaecol        ISSN: 0144-3615            Impact factor:   1.246


  2 in total

Review 1.  Management of Postoperative Lower Urinary Tract Symptoms (LUTS) After Pelvic Organ Prolapse (POP) Repair.

Authors:  Annie Chen; Brian McIntyre; Elise J B De
Journal:  Curr Urol Rep       Date:  2018-07-24       Impact factor: 3.092

2.  Pelvic organ prolapse surgery and health-related quality of life: a follow-up study.

Authors:  Tadesse Belayneh; Abebaw Gebeyehu; Mulat Adefris; Guri Rortveit; Janne Lillelid Gjerde; Tadesse Awoke Ayele
Journal:  BMC Womens Health       Date:  2021-01-02       Impact factor: 2.809

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.