Literature DB >> 29536494

[Somatostatin receptor PET/CT (SSTR-PET/CT)].

C Boy, T Poeppel, J Kotzerke, B J Krause, H Amthauer, R P Baum, I Buchmann, S Ezziddin, D Führer, M Gabriel, T Kuwert, H Lahner, T Lauenstein, H R Maecke, J Nagarajah, F Rösch, K Scheidhauer, M Schmidt, M A Walter, A Bockisch.   

Abstract

The present guideline is focused on quality assurance of somatostatin receptor PET/CT (SSTR-PET/CT) in oncology patients. The document has been developed by a multidisciplinary board of specialists providing consensus of definitions, prerequisites, methodology, operating procedures, assessment, and standardized reporting. In particular, imaging procedures for the two most commonly used radioligands of human SSTR, i. e. 68Ga-DOTATOC and 68Ga-DOTATATE are presented. Overall, SSTR-PET/CT requires close interdisciplinary communication and cooperation of referring and executing medical disciplines, taking into account existing guidelines and recommendations of the European and German medical societies, including the European Association of Nuclear Medicine (EANM), German Society for Endocrinology (DGE), German Society for Nuclear Medicine (DGN) and German Society for Radiology (DRG). Schattauer GmbH.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29536494     DOI: 10.1055/s-0038-1636560

Source DB:  PubMed          Journal:  Nuklearmedizin        ISSN: 0029-5566            Impact factor:   1.379


  5 in total

Review 1.  [Theranostics and hybrid imaging for somatostatin receptor-expressing tumors].

Authors:  Rudolf A Werner; Frank M Bengel; Thorsten Derlin
Journal:  Radiologe       Date:  2020-05       Impact factor: 0.635

2.  The battle on time, money and precision: Da[18F] id vs. [68Ga]liath.

Authors:  Sabri Sahnoun; Patrick Conen; Felix M Mottaghy
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-12       Impact factor: 9.236

3.  Shortened Tracer Uptake Time in GA-68-DOTATOC-PET of Meningiomas Does Not Impair Diagnostic Accuracy and PET Volume Definition.

Authors:  Josefine Graef; Carolin Senger; Christoph Wetz; Alexander D J Baur; Anne K Kluge; Mathias Lukas; Julian M M Rogasch; Thula C Walter-Rittel; David Kohnert; Marcus Makowski; Güliz Acker; Kai Huang; Volker Budach; Holger Amthauer; Imke Schatka; Christian Furth
Journal:  Diagnostics (Basel)       Date:  2020-12-13

4.  CT-derived body composition analysis could possibly replace DXA and BIA to monitor NET-patients.

Authors:  Lennard Kroll; Annie Mathew; Felix Nensa; Harald Lahner; Giulia Baldini; René Hosch; Sven Koitka; Jens Kleesiek; Christoph Rischpler; Johannes Haubold; Dagmar Fuhrer
Journal:  Sci Rep       Date:  2022-08-04       Impact factor: 4.996

5.  Favorable SSTR subtype selectivity of SiTATE: new momentum for clinical [18F]SiTATE PET.

Authors:  Carmen Wängler; Leonie Beyer; Peter Bartenstein; Björn Wängler; Ralf Schirrmacher; Simon Lindner
Journal:  EJNMMI Radiopharm Chem       Date:  2022-09-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.