Literature DB >> 29536281

There is a significant relationship between morning blood pressure surge and increased abdominal aortic intima-media thickness in hypertensive patients.

Ayse Selcan Koc1, Ferıde Fatma Gorgulu2, Yurdaer Donmez3, Yahya Kemal Icen3.   

Abstract

PURPOSE: There are limited data about increased aortic intima-media thickness (A-IMT) in the presence of subclinical target organ damage in hypertensive (HT) patients. In this study, we aimed to determine the frequency of increased A-IMT, the parameters determining increased A-IMT, and the relationship between increased A-IMT and other vascular IMT measurements.
MATERIALS AND METHODS: We prospectively included 265 patients (mean age 54.1 ± 10.6 years, male/female 91/174) with essential HT. Physical examination of all patients was performed. Laboratory data and antihypertensive treatments were recorded. Twenty-four-hour ambulatory blood pressure monitoring (ABPM) was performed. Bilateral carotid, brachial, and femoral artery and abdominal A-IMT values were measured by B-mode ultrasonography (USG). Patients were categorized into two main groups: patients with increased A-IMT (≥ 3 mm) or normal A-IMT (< 3 mm).
RESULTS: Increased A-IMT was detected in 55 patients (20.8%). There was a close relationship between increased A-IMT and advanced age, presence of coronary artery disease, high morning blood pressure surge (MBPS), and bilateral carotid and femoral IMT. Parameters associated with increased A-IMT in univariate analysis were assessed by regression analysis. Left femoral IMT and MBPS were independently associated with increased A-IMT. In the regression model, each 5-mmHg elevation in MBPS increased the risk of increased A-IMT by 34.2%. The cutoff value of MBPS obtained by the ROC curve analysis was 32 mmHg for the prediction of increased A-IMT (sensitivity 76.3%, specificity 63.5%). The area under the curve was 0.784 (95% CI 0.720-0.847, p < 0.001).
CONCLUSION: Abdominal A-IMT increased at a significant rate in patients with HT. An independent association was found between MBPS and A-IMT, which can both be easily detected by ABPM and B-mode USG. The high MBPS level was considered to be a simple and inexpensive method for detecting subclinical target organ damage. A-IMT measurement should also be a part of abdominal USG, which is a routine examination in HT patients.

Entities:  

Keywords:  Aortic intima–media thickness; Morning blood pressure surge

Mesh:

Year:  2018        PMID: 29536281     DOI: 10.1007/s10396-018-0877-y

Source DB:  PubMed          Journal:  J Med Ultrason (2001)        ISSN: 1346-4523            Impact factor:   1.314


  38 in total

1.  Carotid atherosclerosis in relation to systolic and diastolic blood pressure: Kuopio Ischaemic Heart Disease Risk Factor Study.

Authors:  R Salonen; J T Salonen
Journal:  Ann Med       Date:  1991-02       Impact factor: 4.709

Review 2.  Ambulatory blood-pressure monitoring.

Authors:  Thomas G Pickering; Daichi Shimbo; Donald Haas
Journal:  N Engl J Med       Date:  2006-06-01       Impact factor: 91.245

3.  Circadian variation in the timing of stroke onset: a meta-analysis.

Authors:  W J Elliott
Journal:  Stroke       Date:  1998-05       Impact factor: 7.914

4.  Effects of coronary heart disease risk factors on atherosclerosis of selected regions of the aorta and right coronary artery. PDAY Research Group. Pathobiological Determinants of Atherosclerosis in Youth.

Authors:  H C McGill; C A McMahan; E E Herderick; R E Tracy; G T Malcom; A W Zieske; J P Strong
Journal:  Arterioscler Thromb Vasc Biol       Date:  2000-03       Impact factor: 8.311

5.  Prognostic significance for stroke of a morning pressor surge and a nocturnal blood pressure decline: the Ohasama study.

Authors:  Hirohito Metoki; Takayoshi Ohkubo; Masahiro Kikuya; Kei Asayama; Taku Obara; Junichiro Hashimoto; Kazuhito Totsune; Haruhisa Hoshi; Hiroshi Satoh; Yutaka Imai
Journal:  Hypertension       Date:  2005-12-27       Impact factor: 10.190

6.  Exaggerated morning blood pressure surge and cardiovascular events. A 5-year longitudinal study in normotensive and well-controlled hypertensive elderly.

Authors:  A Amici; P Cicconetti; C Sagrafoli; A Baratta; P Passador; T Pecci; G Tassan; W Verrusio; V Marigliano; M Cacciafesta
Journal:  Arch Gerontol Geriatr       Date:  2008-12-12       Impact factor: 3.250

7.  The relationship between morning hypertension and sleep quality in patients with obstructive sleep apnea syndrome.

Authors:  Nobuo Sasaki; Ryoji Ozono; Ryo Yamauchi; Kazushi Teramen; Yoshinobu Edahiro; Kiyomi Ishii; Ayako Seto; Yasuki Kihara
Journal:  Clin Exp Hypertens       Date:  2013-03-26       Impact factor: 1.749

Review 8.  New European, American and International guidelines for hypertension management: agreement and disagreement.

Authors:  George S Stergiou; Eleanna V Salgami
Journal:  Expert Rev Cardiovasc Ther       Date:  2004-05

9.  Carotid, aorta and renal arteries intima-media thickness in patients with sporadic idiopathic hypoparathyroidism.

Authors:  Deshraj Meena; Mahesh Prakash; Yashdeep Gupta; Sanjay Kumar Bhadada; Niranjan Khandelwal
Journal:  Indian J Endocrinol Metab       Date:  2015 Mar-Apr

10.  2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC).

Authors:  Giuseppe Mancia; Robert Fagard; Krzysztof Narkiewicz; Josep Redon; Alberto Zanchetti; Michael Böhm; Thierry Christiaens; Renata Cifkova; Guy De Backer; Anna Dominiczak; Maurizio Galderisi; Diederick E Grobbee; Tiny Jaarsma; Paulus Kirchhof; Sverre E Kjeldsen; Stéphane Laurent; Athanasios J Manolis; Peter M Nilsson; Luis Miguel Ruilope; Roland E Schmieder; Per Anton Sirnes; Peter Sleight; Margus Viigimaa; Bernard Waeber; Faiez Zannad; Josep Redon; Anna Dominiczak; Krzysztof Narkiewicz; Peter M Nilsson; Michel Burnier; Margus Viigimaa; Ettore Ambrosioni; Mark Caufield; Antonio Coca; Michael Hecht Olsen; Roland E Schmieder; Costas Tsioufis; Philippe van de Borne; Jose Luis Zamorano; Stephan Achenbach; Helmut Baumgartner; Jeroen J Bax; Héctor Bueno; Veronica Dean; Christi Deaton; Cetin Erol; Robert Fagard; Roberto Ferrari; David Hasdai; Arno W Hoes; Paulus Kirchhof; Juhani Knuuti; Philippe Kolh; Patrizio Lancellotti; Ales Linhart; Petros Nihoyannopoulos; Massimo F Piepoli; Piotr Ponikowski; Per Anton Sirnes; Juan Luis Tamargo; Michal Tendera; Adam Torbicki; William Wijns; Stephan Windecker; Denis L Clement; Antonio Coca; Thierry C Gillebert; Michal Tendera; Enrico Agabiti Rosei; Ettore Ambrosioni; Stefan D Anker; Johann Bauersachs; Jana Brguljan Hitij; Mark Caulfield; Marc De Buyzere; Sabina De Geest; Geneviève Anne Derumeaux; Serap Erdine; Csaba Farsang; Christian Funck-Brentano; Vjekoslav Gerc; Giuseppe Germano; Stephan Gielen; Herman Haller; Arno W Hoes; Jens Jordan; Thomas Kahan; Michel Komajda; Dragan Lovic; Heiko Mahrholdt; Michael Hecht Olsen; Jan Ostergren; Gianfranco Parati; Joep Perk; Jorge Polonia; Bogdan A Popescu; Zeljko Reiner; Lars Rydén; Yuriy Sirenko; Alice Stanton; Harry Struijker-Boudier; Costas Tsioufis; Philippe van de Borne; Charalambos Vlachopoulos; Massimo Volpe; David A Wood
Journal:  Eur Heart J       Date:  2013-06-14       Impact factor: 29.983

View more
  3 in total

1.  Aortic intima-media thickness can be used to determine target organ damage in adult patients with coronary artery disease risk factors.

Authors:  Atilla Bulut; Armağan Acele; Yurdaer Donmez; Burcak Cakır Pekoz; Murat Erdogan; Hilmi Erdem Sumbul; Yahya Kemal Icen; Mevlut Koc
Journal:  Arch Med Sci Atheroscler Dis       Date:  2019-07-29

2.  Carotid intima-media thickness values are significantly higher in patients with prediabetes compared to normal glucose metabolism.

Authors:  Atilla Bulut; Begum Avci
Journal:  Medicine (Baltimore)       Date:  2019-11       Impact factor: 1.817

3.  Increased aortic intima-media thickness may be used to detect macrovascular complications in adult type II diabetes mellitus patients.

Authors:  Ayse Selcan Koc; Hilmi Erdem Sumbul
Journal:  Cardiovasc Ultrasound       Date:  2018-06-12       Impact factor: 2.062

  3 in total