Literature DB >> 29533457

Automatic deformable registration of histological slides to μCT volume data.

N Chicherova1,2, S E Hieber2, A Khimchenko2, C Bikis2, B Müller2, P Cattin1.   

Abstract

Localizing a histological section in the three-dimensional dataset of a different imaging modality is a challenging 2D-3D registration problem. In the literature, several approaches have been proposed to solve this problem; however, they cannot be considered as fully automatic. Recently, we developed an automatic algorithm that could successfully find the position of a histological section in a micro computed tomography (μCT) volume. For the majority of the datasets, the result of localization corresponded to the manual results. However, for some datasets, the matching μCT slice was off the ground-truth position. Furthermore, elastic distortions, due to histological preparation, could not be accounted for in this framework. In the current study, we introduce two optimization frameworks based on normalized mutual information, which enabled us to accurately register histology slides to volume data. The rigid approach allocated 81 % of histological sections with a median position error of 8.4 μm in jaw bone datasets, and the deformable approach improved registration by 33 μm with respect to the median distance error for four histological slides in the cerebellum dataset.
© 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

Keywords:  2D-3D registration; histology; micro computed tomography; multimodal; slice-to-volume registration

Mesh:

Year:  2018        PMID: 29533457     DOI: 10.1111/jmi.12692

Source DB:  PubMed          Journal:  J Microsc        ISSN: 0022-2720            Impact factor:   1.758


  2 in total

1.  Elastic transformation of histological slices allows precise co-registration with microCT data sets for a refined virtual histology approach.

Authors:  Jonas Albers; Angelika Svetlove; Justus Alves; Alexander Kraupner; Francesca di Lillo; M Andrea Markus; Giuliana Tromba; Frauke Alves; Christian Dullin
Journal:  Sci Rep       Date:  2021-05-25       Impact factor: 4.379

2.  Ex vivo evaluation of an atherosclerotic human coronary artery via histology and high-resolution hard X-ray tomography.

Authors:  Marzia Buscema; Simone E Hieber; Georg Schulz; Hans Deyhle; Alexander Hipp; Felix Beckmann; Johannes A Lobrinus; Till Saxer; Bert Müller
Journal:  Sci Rep       Date:  2019-10-04       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.