J H Cohen, J P Aubry, M H Jouvin, J Wijdenes, J Bancherau, M Kazatchkine, J P Revillard.
Abstract
A sensitive enhancing system was developed for detecting low density cell surface antigen by flow cytometry. The system termed the 'super avidin-biotin system' (SABS) uses biotinylated antibody, phycoerythrin-streptavidin (StreptA-PE), biotinylated goat anti-streptavidin antibody, and StreptA-PE. CR1 complement receptor antigenic sites were quantified on erythrocytes from healthy individuals and patients with antibodies against human immunodeficiency virus (HIV) using SABS and a conventional radioimmunoassay (RIA) with monoclonal anti-CR1 antibody. As little as 50 sites/cell were detected using either SABS or RIA. Accurate quantification of CR1 antigenic sites was achieved within the range of 100-1300 sites/cell. Similar results were obtained using either of the two methods. Intra-assay and day-to-day reproducibilities using SABS were 2% and 12% respectively, comparable to those of conventional RIA measurements. In addition to enumeration of CR1 on erythrocytes for clinical purposes, the use of SABS may probably be extended to a wide number of situations where a sensitive detection of low density cell surface antigen is needed.Entities:
Mesh:
Substances:
Year: 1987 PMID: 2952733 DOI: 10.1016/0022-1759(87)90031-7
Source DB: PubMed Journal: J Immunol Methods ISSN: 0022-1759 Impact factor: 2.303