Literature DB >> 29525926

Detection accuracy of maxillary sinus floor septa in panoramic radiographs using CBCT as gold standard: a multi-observer receiver operating characteristic (ROC) study.

A C Lang1, R K Schulze2.   

Abstract

OBJECTIVES: To investigate diagnostic accuracy of panoramic radiography in detecting maxillary sinus floor septa by means of a multi-observer receiver operating characteristic (ROC) analysis and a standardized protocol for reporting (STARD protocol; Clin Chem 49(1):1-6, 2003).
MATERIAL AND METHODS: From our database, 25 cone beam computed tomographies (CBCTs) were selected with one maxillary sinus floor septum (height ≥ 2.5 mm). For the same patient, a recent panoramic radiograph (PAN) had to be available in the database. As controls, 28 CBCTs plus corresponding PANs without evidence of a sinus septum were selected. Using the CBCTs as ground truth, 17 observers from our dental school on a five-point confidence scale rated both sinuses in all 53 PANs with respect to presence/absence of a sinus septum. Areas beneath ROC curves (Az-values), sensitivity/specificity (SNT/SPF), positive/negative predictive values (PPV, NPV), and positive/negative likelihood ratios (LR+, LR-) were computed for each observer and pooled over all observers. Inter-rater reproducibility was assessed by means of the intraclass coefficient (ICC) using a two-way random effects model.
RESULTS: A pooled Az-value of 0.839 was observed (SNT 84.6%, SPF 73.5%). PPV ranged between 0.492 and 0.824 (median 0.627) and NPV between 0.838 and 0.976 (median 0.917). A median LR+ of 3.567 was computed (LR- median 0.193). Inter-rater reliability revealed an ICC of 0.55 (95% confidence interval 0.48 to 0.62).
CONCLUSIONS: Our results indicate that PAN is a moderately accurate method for sinus elevation planning for the purpose of septum detection. Ruling out a septum by PAN seems to work more accurately than ruling in. CLINICAL RELEVANCE: For the purpose of maxillary sinus floor septa detection, panoramic radiography can be relatively safely advocated, particularly for judgment of a septum-free sinus.

Entities:  

Keywords:  CBCT; Diagnostic accuracy; Maxillary sinus septa; Panoramic radiography; ROC analysis

Mesh:

Year:  2018        PMID: 29525926     DOI: 10.1007/s00784-018-2414-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  2 in total

1.  Displacement of the full body of a dental implant into the sinus space without membrane perforation and subsequent osseointegration: a case report.

Authors:  Xun Xia; Zhen-Yu Wei; Hong-Wu Wei
Journal:  J Int Med Res       Date:  2021-12       Impact factor: 1.671

2.  Prevalence and characterization of maxillary sinus septa in a brazilian population.

Authors:  Deusa-Maria-Mendes Furtado; Paulo-Antônio Martins-Júnior; Tatielly-Karine-Costa Alves; Rafael-Pereira-da Mata Santos; Danielle-Carvalho-Oliveira Coutinho; Idalísio-Soares-Aranha Neto; Bruno-César-Ladeira Vidigal; Guilherme-Augusto-Alves de Oliveira; Micena-Roberta-Miranda Alves E Silva; Flávio-Ricardo Manzi
Journal:  J Clin Exp Dent       Date:  2021-07-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.