Literature DB >> 29522223

Evaluation of the Accuracy of Two Marking Methods and the Novel toriCAM Application for Toric Intraocular Lens Alignment.

Andreas Pallas, Tun Kuan Yeo, Michelle Trevenen, Graham Barrett.   

Abstract

PURPOSE: To compare the accuracy of two common reference marking methods for toric intraocular lens alignment before and after using the novel toriCAM application.
METHODS: In this prospective, randomized study, 22 participants were randomly allocated to two groups, either freehand or slit-lamp-assisted marking. Corneal markings at 0° and 180° were made using either method. The toriCAM application on a smartphone was then used to assess the rotational alignment of these markings and compared to the actual alignment as measured by the Zaldivar calipers on the iTrace Topographer (Tracey Technologies, Houston, TX) as a reference. The errors in marking with and without using the application were analyzed for all patients in each cohort and determined for each marking method.
RESULTS: Twenty eyes of 11 patients were marked using the freehand method and 20 eyes of the other 11 patients were marked using the slit-lamp method. The mean absolute error of all markings before toriCAM adjustment was 3.18° ± 2.22°. This was significantly reduced to 1.28° ± 1.34° after using the application (P < .001). This improvement was also noted separately in the freehand and slit-lamp groups. Comparison of the freehand and slit-lamp methods did not show any statistically significant difference in accuracy at both time points.
CONCLUSIONS: The novel toriCAM application is able to significantly improve the accuracy of reference marking for both freehand and slit-lamp methods. [J Refract Surg. 2018;34(3):150-155.]. Copyright 2018, SLACK Incorporated.

Entities:  

Mesh:

Year:  2018        PMID: 29522223     DOI: 10.3928/1081597X-20180115-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  8 in total

Review 1.  Clinically useful smartphone ophthalmic imaging techniques.

Authors:  Amar Pujari; Gunjan Saluja; Divya Agarwal; Harathy Selvan; Namrata Sharma
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2020-09-11       Impact factor: 3.117

2.  Comparison between using INTEGRA and manual method in determining axis for intraocular lens implantation: Preliminary retrospective study.

Authors:  Marcin Jaworski; Dorota Wyględowska-Promieńska; Piotr Jaworski; Krzysztof Jaskot; Robert Bieda; Richard Packard
Journal:  Medicine (Baltimore)       Date:  2020-01       Impact factor: 1.889

3.  Verion digital marking versus smartphone-assisted manual marking and isolated manual marking in toric intraocular lens implantation.

Authors:  Zain Irfan Khatib; Suhas S Haldipurkar; Vijay Shetty
Journal:  Indian J Ophthalmol       Date:  2020-03       Impact factor: 1.848

Review 4.  Toric intraocular lenses: Expanding indications and preoperative and surgical considerations to improve outcomes.

Authors:  Vivek Mahendrapratap Singh; Muralidhar Ramappa; Somasheila I Murthy; Audrey Talley Rostov
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

Review 5.  A Review of Smartphone Apps Used for Toric Intraocular Lens Calculation and Alignment.

Authors:  Yarrow Scantling-Birch; Hasan Naveed; Ritika Mukhija; Mayank A Nanavaty
Journal:  Vision (Basel)       Date:  2022-02-18

Review 6.  The Development and Clinical Application of Innovative Optical Ophthalmic Imaging Techniques.

Authors:  Palaiologos Alexopoulos; Chisom Madu; Gadi Wollstein; Joel S Schuman
Journal:  Front Med (Lausanne)       Date:  2022-06-30

7.  Mobile App for Pre- and Intraoperative Assessment of Astigmatism Correction with Toric Intraocular Lenses in Cataract Surgery.

Authors:  Francisco Aecio Fernandes Dias; Vinicius Jose Fernandes Dias; Barbara de Araujo Lima Dutra; Anna Christina Siqueira Marques; Edgar Marçal; Abrahao da Rocha Lucena; Joao Crispim Ribeiro
Journal:  J Ophthalmol       Date:  2020-03-15       Impact factor: 1.909

8.  Clinical evaluation of toric intraocular lens implantation based on iTrace wavefront keratometric astigmatism.

Authors:  Zhe Zhang; Hui Li; Jing Zhou; Yaqin Zhang; Suhua Zhang
Journal:  BMC Ophthalmol       Date:  2020-11-16       Impact factor: 2.209

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.