Long-term Clinical Outcomes of Pars Plana Versus Anterior Chamber Placement of Glaucoma Implant Tubes.

Vivian L Qin1, Mona Kaleem2, Felipe F Conti3, Edward J Rockwood3, Annapurna Singh3, Shalini Sood-Mendiratta3, Jonathan E Sears3, Fabiana Q Silva3, Jonathan Eisengart3, Rishi P Singh3.   

Abstract

PURPOSE: To compare long-term surgical outcomes and complications of pars plana (PP) tube implantation with conventional anterior chamber (AC) tube implantation.
MATERIALS AND METHODS: Records of patients undergoing glaucoma tube implant surgery at a single institution between 2007 and 2015 were retrospectively reviewed. Eyes were matched for glaucoma diagnosis and patient age. Demographics, baseline characteristics, and treatment outcomes were recorded. Surgical success was defined as intraocular pressure (IOP) between 6 and 21 mm Hg, no subsequent glaucoma surgeries performed, and at least light perception vision.
RESULTS: Fifty-seven eyes that underwent Ahmed or Baerveldt glaucoma drainage device surgery with PP tube placement were compared with 57 eyes with AC tube placement. Mean follow-up was 43.5 months in the PP group and 35.3 months in the AC group (P=0.02). Forty-nine (86.0%) PP eyes and 46 (80.7%) AC eyes achieved surgical success (P=0.45). At last follow-up, mean IOP decreased from 29.0 to 15.1 mm Hg in the PP group (P<0.01) and from 32.7 to 15.6 mm Hg in the AC group (P<0.01). Mean number of medications decreased from 2.9 to 1.1 in the PP group (P<0.01) and from 2.8 to 1.3 in the AC group (P<0.01). Mean IOP and number of medications were similar between PP and AC groups at baseline, last follow-up, and all interim time points (P>0.05 for all). There were 16 complications in the PP group and 14 in the AC group (P=0.67).
CONCLUSIONS: Long-term results of glaucoma tube implant surgery with PP versus AC implantation shows effective IOP control with similar rates of surgical success.

Entities:  

Mesh:

Year:  2018        PMID: 29521717     DOI: 10.1097/IJG.0000000000000931

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  9 in total

1.  The Effect of Tube Location on Corneal Endothelial Cells in Patients with Ahmed Glaucoma Valve.

Authors:  Qi Zhang; Yingna Liu; Sukhumal Thanapaisal; Julius Oatts; Yetao Luo; Gui-Shuang Ying; Junming Wang; Stephen D McLeod; Steven J Gedde; Ying Han
Journal:  Ophthalmology       Date:  2020-06-27       Impact factor: 12.079

Review 2.  Comparison of pars plana with anterior chamber glaucoma drainage device implantation for glaucoma: a meta-analysis.

Authors:  Bin Wang; Wenwei Li
Journal:  BMC Ophthalmol       Date:  2018-08-29       Impact factor: 2.209

3.  Effects of Baerveldt Glaucoma Implant Surgery on Corneal Endothelial Cells of Patients with No History of Trabeculectomy.

Authors:  Naoki Tojo; Atsushi Hayashi; Mizuki Hamada
Journal:  Clin Ophthalmol       Date:  2019-11-28

4.  Combined pars plana glaucoma drainage device placement and vitrectomy using a vitrectomy sclerotomy site for tube placement: a case series.

Authors:  Enchi Kristina Chang; Sanchay Gupta; Marika Chachanidze; John B Miller; Ta Chen Chang; David A Solá-Del Valle
Journal:  BMC Ophthalmol       Date:  2021-02-25       Impact factor: 2.209

5.  Pars plana Aurolab aqueous drainage implantation for refractory glaucoma: Outcome of a new modified technique.

Authors:  Mohideen A Kader; Shylesh B Dabke; Aakriti G Shukla; Venugopal Reddy; Syed M Abdul Khadar; Devendra Maheshwari; Rengappa Ramakrishnan
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 2.969

6.  Commentary: Placement of the tube of a glaucoma drainage device: Different horses for different courses.

Authors:  Vanita Pathak Ray
Journal:  Indian J Ophthalmol       Date:  2022-03       Impact factor: 1.848

7.  Outcomes of Anterior Chamber, Sulcus, and Pars Plana Glaucoma Drainage Device Placement in Glaucoma Patients.

Authors:  Sandy Samuel; Enchi K Chang; Sanchay Gupta; Marika Chachanidze; Cameron E Neeson; John B Miller; Ta Chen Chang; David A Solá-Del Valle
Journal:  J Ophthalmol       Date:  2022-07-20       Impact factor: 1.974

8.  Tube-Iris Distance and Corneal Endothelial Cell Damage Following Ahmed Glaucoma Valve Implantation.

Authors:  Yitak Kim; Won Jeong Cho; Jung Dong Kim; Hyuna Cho; Hyoung Won Bae; Chan Yun Kim; Wungrak Choi
Journal:  J Clin Med       Date:  2022-08-28       Impact factor: 4.964

9.  Corneal endothelial cell changes and surgical results after Ahmed glaucoma valve implantation: ciliary sulcus versus anterior chamber tube placement.

Authors:  Joo Yeon Kim; Jihei Sara Lee; Taekjune Lee; Duri Seo; Wungrak Choi; Hyoung Won Bae; Chan Yun Kim
Journal:  Sci Rep       Date:  2021-06-21       Impact factor: 4.379

  9 in total