Literature DB >> 29519991

Volar percutaneous screw fixation for scaphoid nonunion.

M Gurger1, M Yilmaz1, E Yilmaz1, S Altun2.   

Abstract

BACKGROUND: Percutaneous screw fixation is widely used in acute fractures of the scaphoid. In this study, we aimed to present our results with volar percutaneous screw fixation in patients with scaphoid nonunions.
METHODOLOGY: A total of 12 patients with scaphoid nonunion (≥13 weeks) that underwent volar percutaneous screw fixation were evaluated retrospectively. Two of the patients were female, and 10 were male. Mean age was 27 years (range = 19-41). The mean time that elapsed between the fracture and surgical procedure was 7.5 months (range = 4-12). According to the anatomic location, 33.3% were proximal pole, and 67.7% were waist fractures. All of the patients underwent percutaneous fixation with a headless cannulated screw from volar part under fluoroscopic guidance. Clinical evaluation was performed according to the modified mayo wrist scoring system (MMWS). The absence of a radiolucent fracture line on the radiographs was considered "union" on radiological evaluation.
RESULTS: The mean follow-up time was 18 weeks (range = 8-36). Union was achieved in all patients (91.6%), except one. The mean time to union was 15.5 weeks (range = 8-30). Based on MMWS system, 8 patients were interpreted as excellent, 3 patients as good.
CONCLUSION: Percutaneous fixation in appropriate patients provides satisfactory results with high union and minimal complication rates in scaphoid nonunions.

Entities:  

Keywords:  Nonunion; percutaneous fixation; scaphoid; volar

Mesh:

Year:  2018        PMID: 29519991     DOI: 10.4103/njcp.njcp_24_17

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  3 in total

Review 1.  A systematic review of mechanical stabilization by screw fixation without bone grafting in the management of stable scaphoid non-union.

Authors:  Lugman Elgayar; Mohammed Elmajee; Ahmed Aljawadi; Ahmed Abdelaal; Shoaib Khan; Anand Pillai
Journal:  J Clin Orthop Trauma       Date:  2021-03-11

2.  Volar Plating versus Headless Compression Screw Fixation of Scaphoid Nonunions: A Meta-analysis of Outcomes.

Authors:  Duncan S Van Nest; Michael Reynolds; Eugene Warnick; Matthew Sherman; Asif M Ilyas
Journal:  J Wrist Surg       Date:  2021-01-03

3.  [Nitinol memory alloy two foot fixator with autologous cancellous bone grafting for old scaphoid fracture and nonunion].

Authors:  Muguo Song; Xiaoqing He; Chuan Li; Yongqing Xu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2020-06-15
  3 in total