Accelerated phase contrast MRI using hybrid one- and two-sided flow encodings only (HOTFEO).

Da Wang1,2, Aichi Chien1,2, Jiaxin Shao2, Fadil Abbas Ali2,3, Peng Hu1,2.   

Abstract

The aim of this work was to develop and evaluate a fast phase contrast magnetic resonance imaging (PC-MRI) technique with hybrid one- and two-sided flow encodings only (HOTFEO) for accurate blood flow and velocity measurements of three-directional velocity encoding PC-MRI. Four-dimensional (4D) PC-MRI acquires flow-compensated (FC) and three-directional flow-encoded (FE) echoes in an interleaved fashion. We hypothesize that the blood flow velocity direction (not magnitude) has minimal change between two consecutive cardiac phases. This assumption provides a velocity direction constraint that can achieve 4/3-fold acceleration using three-directional FE data to calculate FC data instead of acquiring them. The HOTFEO acquisition pattern can address the ill-conditioned constraint and improve the calculation accuracy. HOTFEO was evaluated in healthy volunteers and compared with conventional two-dimensional (2D) and 4D flow imaging techniques with FC and three-directional FE acquisitions (FC/3FE). Compared with FC/3FE, Bland-Altman tests showed that the 4/3-fold accelerated HOTFEO technique resulted in relatively small bias error for total volumetric flow (0.89% for prospective 2D data, -1.19% for retrospective 4D data and -3.40% for prospective 4D data) and maximum peak velocity (0.50% for prospective 2D data, -0.17% for retrospective 4D data and -2.00% for prospective 4D data) measurements in common carotid arteries. HOTFEO can accelerate three-directional velocity encoding PC-MRI whilst maintaining the measurement accuracy of the total volumetric flow and maximum peak velocity.
Copyright © 2018 John Wiley & Sons, Ltd.

Keywords:  4D flow; fast phase contrast MRI; flow quantification; hybrid one- and two-sided flow encoding only; temporal resolution and temporal footprint; velocity direction constraint

Mesh:

Year:  2018        PMID: 29517139     DOI: 10.1002/nbm.3904

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  2 in total

1.  Improved acceleration of phase-contrast flow imaging with magnitude difference regularization.

Authors:  Taehoon Shin; Wanyong Shin
Journal:  Magn Reson Imaging       Date:  2019-12-02       Impact factor: 2.546

2.  Two-Minute k-Space and Time-accelerated Aortic Four-dimensional Flow MRI: Dual-Center Study of Feasibility and Impact on Velocity and Wall Shear Stress Quantification.

Authors:  Emilie Bollache; Kristopher D Knott; Kelly Jarvis; Redha Boubertakh; Ryan Scott Dolan; Claudia Camaioni; Louise Collins; Paul Scully; Sydney Rabin; Thomas Treibel; James C Carr; Pim van Ooij; Jeremy D Collins; Julia Geiger; James C Moon; Alex J Barker; Steffen E Petersen; Michael Markl
Journal:  Radiol Cardiothorac Imaging       Date:  2019-06-27
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.