| Literature DB >> 29516243 |
Thea Buchan1, Miles Walkden1, Kathryn Jenkins2, Pervez Sultan2, Steve Bandula3.
Abstract
AIM: To evaluate the effect of high-frequency jet ventilation (HFJV) in place of standard intermittent positive-pressure ventilation (IPPV) on procedure duration, patient radiation dose, complication rates, and outcomes during CT-guided cryoablation of small renal tumours.Entities:
Keywords: Cancer; Computed Tomography; Cryoablation; Kidney; Ventilation
Mesh:
Year: 2018 PMID: 29516243 PMCID: PMC5976690 DOI: 10.1007/s00270-018-1921-4
Source DB: PubMed Journal: Cardiovasc Intervent Radiol ISSN: 0174-1551 Impact factor: 2.740
Patient demographic details—mean (range)
| IPPV group | HFJV group | |
|---|---|---|
| Number of procedures | 50 | 50 |
|
| ||
| Male | 35 | 39 |
| Female | 15 | 11 |
| Age (years) | 64 (28–86) | 69 (41–85) |
| Weight (Kg) | 91 (73–138) | 85 (65–128) |
| Height (metres) | 1.70 (1.56–1.91) | 169 (1.5–1.87) |
| Body mass index (kg/m2) | 31.4 (22.2–43) | 29.5 (21.1–42.2) |
| ASA | 2.54 | 2.68 |
Baseline tumour characteristics
| IPPV | HFJV | ||
|---|---|---|---|
| PADUA score | 7.2 | 7.41 | |
| Size (mm) | 25.63 | 28.74 | 0.1322 |
|
| |||
| Clear cell | 31 | 35 | |
| Chromophobe | 3 | 5 | |
| Papillary | 12 | 8 | |
| Spindle cell | 1 | 0 | |
| Oncocytoma | 1 | 0 | |
| Not biopsied | 2 | 2 | |
Comparison of procedural details
| IPPV | HFJV | ||
|---|---|---|---|
|
| |||
| Prone | 38 | 31 | – |
| Left lateral | 5 | 9 | – |
| Right lateral | 7 | 10 | – |
| Induction time (total anaesthesia time minus procedure time) | 30 min 4 s | 31 min | 0.2788 |
| Number of probes | 3.922 | 4.24 | 0.3427 |
| Hydro or pneumo-dissection | 25 | 23 | – |
Fig. 1Box-and-whisker plot showing total procedure time (mean and standard deviation) in minutes for the two ventilation groups
Fig. 2Box-and-whisker plot showing needle placement time (mean and standard deviation) in minutes for the two ventilation groups
Comparison of time/dose/difficulty
| IPPV | HFJV | ||
|---|---|---|---|
| Total procedure time (minutes) | 142.4 | 105.8 | < 0.0001 |
| Needle placement time (time to achieve probe positions—minutes) | 100.2 | 66.2 | < 0.0001 |
| Number of acquisitions for probe placement | 78.8 | 59.2 | 0.0002 |
| Patient dose collected as dose length product (mGycm2) | 1975 | 1449 | 0.0027 |
Fig. 3Box-and-whisker plot showing total procedure dose (mean and standard deviation) as dose length product for the two ventilation groups