Abstract
BACKGROUND: Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests.Entities:
Keywords: Ethiopia; Helicobacter pylori; SD BIOLINE Ag rapid test; Stool antigen
Year: 2018 PMID: 29515332 PMCID: PMC5836355 DOI: 10.1186/s12907-018-0071-6
Source DB: PubMed Journal: BMC Clin Pathol ISSN: 1472-6890
Serology results of the SD BIOLINE H. pylori Ag rapid test, SD H. pylori Ag ELISA test, and ZE-STEP H. pylori Ag ELISA at University of Gondar Hospital, 2015
| SD BIOLINE | ||||
|---|---|---|---|---|
| Positive N (%) | Negative N (%) | Total N (%) | ||
| SD | Positive | 72(96.0%) | 20 (15.9%) | 92 (45.8%) |
| Negative | 3 (4.0%) | 106 (84.1%) | 109 (54.2%) | |
| EZ- STEP ELISA | Positive | 65 (86.7%) | 16 (12.7%) | 81 (40.3%) |
| Negative | 10 (13.3%) | 110 (87.3%) | 120 (59.7%) | |
| EZ-STEP + SD | Positive | 65 (86.7%) | 3 (2.4%) | 68 (33.8%) |
| Negative | 10 (13.3%) | 123 (97.6%) | 133 (66.2%) | |
Ag Antigen, ELISA Enzyme Linked Immunosorbent Assay, N number, SD Standard Diagnostics
Performance result of the SD BIOLINE H. pylori Ag rapid test and dBest H. pylori Test Disk rapid Antibody test using EZ- STEP ELISA and SD H. pylori Ag ELISA test as standard at University of Gondar Hospital, 2015
| Type of test | Sensitivity %(95%CI) | Specificity %(95%CI) | PPV %(95%CI) | NPV %(95%CI) | Kappa value N(95%CI) | P value |
|---|---|---|---|---|---|---|
| Ag rapid test (SD BIOLINE) | 95.6 (88.8–98.8) | 92.5 (89–94.1) | 86.7 (80.5–89.6) | 97.6 (93.9–99.3) | 0.859 (0.759–0.906) | < 0.001 |
| Antibody rapid test (dBest) | 75 (65.3–83.5) | 30.8 (25.9–35.1) | 35.7 (31.1–39.7) | 70.7 (59.4–80.6) | 0.046 (−0.069–0.147) | 0.416 |
Ag Antigen, CI confidence interval, ELISA Enzyme Linked Immunosorbent Assay, N number, NPV negative predictive value, PPV positive predictive value, SD Standard Diagnostics