Literature DB >> 29509148

Dose distribution of secondary radiation in a water phantom for a proton pencil beam-EURADOS WG9 intercomparison exercise.

L Stolarczyk1, S Trinkl, M Romero-Expósito, N Mojżeszek, I Ambrozova, C Domingo, M Davídková, J Farah, M Kłodowska, Ž Knežević, M Liszka, M Majer, S Miljanić, O Ploc, M Schwarz, R M Harrison, P Olko.   

Abstract

Systematic 3D mapping of out-of-field doses induced by a therapeutic proton pencil scanning beam in a 300  ×  300  ×  600 mm3 water phantom was performed using a set of thermoluminescence detectors (TLDs): MTS-7 (7LiF:Mg,Ti), MTS-6 (6LiF:Mg,Ti), MTS-N (natLiF:Mg,Ti) and TLD-700 (7LiF:Mg,Ti), radiophotoluminescent (RPL) detectors GD-352M and GD-302M, and polyallyldiglycol carbonate (PADC)-based (C12H18O7) track-etched detectors. Neutron and gamma-ray doses, as well as linear energy transfer distributions, were experimentally determined at 200 points within the phantom. In parallel, the Geant4 Monte Carlo code was applied to calculate neutron and gamma radiation spectra at the position of each detector. For the cubic proton target volume of 100  ×  100  ×  100 mm3 (spread out Bragg peak with a modulation of 100 mm) the scattered photon doses along the main axis of the phantom perpendicular to the primary beam were approximately 0.5 mGy Gy-1 at a distance of 100 mm and 0.02 mGy Gy-1 at 300 mm from the center of the target. For the neutrons, the corresponding values of dose equivalent were found to be ~0.7 and ~0.06 mSv Gy-1, respectively. The measured neutron doses were comparable with the out-of-field neutron doses from a similar experiment with 20 MV x-rays, whereas photon doses for the scanning proton beam were up to three orders of magnitude lower.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29509148     DOI: 10.1088/1361-6560/aab469

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  High CT doses return to the agenda.

Authors:  W Rühm; R M Harrison
Journal:  Radiat Environ Biophys       Date:  2019-12-16       Impact factor: 1.925

Review 2.  Neutron dose and its measurement in proton therapy-current State of Knowledge.

Authors:  Roger Antoine Hälg; Uwe Schneider
Journal:  Br J Radiol       Date:  2020-01-21       Impact factor: 3.039

3.  Validation of a Monte Carlo Framework for Out-of-Field Dose Calculations in Proton Therapy.

Authors:  Marijke De Saint-Hubert; Nico Verbeek; Christian Bäumer; Johannes Esser; Jörg Wulff; Racell Nabha; Olivier Van Hoey; Jérémie Dabin; Florian Stuckmann; Fabiano Vasi; Stephan Radonic; Guillaume Boissonnat; Uwe Schneider; Miguel Rodriguez; Beate Timmermann; Isabelle Thierry-Chef; Lorenzo Brualla
Journal:  Front Oncol       Date:  2022-06-08       Impact factor: 5.738

4.  ANALYTICAL MODEL TO ESTIMATE EQUIVALENT DOSE FROM INTERNAL NEUTRONS IN PROTON THERAPY OF CHILDREN WITH INTRACRANIAL TUMORS.

Authors:  Kyle J Gallagher; Phillip J Taddei
Journal:  Radiat Prot Dosimetry       Date:  2019-06-01       Impact factor: 0.972

5.  Modelling and measurements of distributions in an adult human phantom undergoing proton scanning beam radiotherapy: lung- and prostate-located tumours.

Authors:  Monika Puchalska
Journal:  Radiat Environ Biophys       Date:  2021-03-02       Impact factor: 1.925

6.  Proton Radiotherapy Could Reduce the Risk of Fatal Second Cancers for Children with Intracranial Tumors in Low- and Middle-Income Countries.

Authors:  Kyle J Gallagher; Bassem Youssef; Rola Georges; Anita Mahajan; Joelle Ann Feghali; Racile Nabha; Zeina Ayoub; Wassim Jalbout; Phillip J Taddei
Journal:  Int J Part Ther       Date:  2021-02-17

7.  Out-of-Field Doses Produced by a Proton Scanning Beam Inside Pediatric Anthropomorphic Phantoms and Their Comparison With Different Photon Modalities.

Authors:  Željka Knežević; Liliana Stolarczyk; Iva Ambrožová; Miguel Á Caballero-Pacheco; Marie Davídková; Marijke De Saint-Hubert; Carles Domingo; Kinga Jeleń; Renata Kopeć; Dawid Krzempek; Marija Majer; Saveta Miljanić; Natalia Mojżeszek; Maite Romero-Expósito; Immaculada Martínez-Rovira; Roger M Harrison; Paweł Olko
Journal:  Front Oncol       Date:  2022-07-22       Impact factor: 5.738

8.  Neutron Radiation Dose Measurements in a Scanning Proton Therapy Room: Can Parents Remain Near Their Children During Treatment?

Authors:  Vladimir Mares; Jad Farah; Marijke De Saint-Hubert; Szymon Domański; Carles Domingo; Martin Dommert; Magdalena Kłodowska; Katarzyna Krzempek; Michał Kuć; Immaculada Martínez-Rovira; Edyta Michaś; Natalia Mojżeszek; Łukasz Murawski; Ondrej Ploc; Maite Romero-Expósito; Marco Tisi; François Trompier; Olivier Van Hoey; Laurent Van Ryckeghem; Marek Wielunski; Roger M Harrison; Liliana Stolarczyk; Pawel Olko
Journal:  Front Oncol       Date:  2022-07-14       Impact factor: 5.738

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.