OBJECTIVES: The aim of this study was to assess the dimensional accuracy of fused deposition modeling (FDM)-, Polyjet-, and stereolithography (SLA)-produced models by comparing them to traditional plaster casts.
MATERIALS AND METHODS: A total of 12 maxillary and mandibular posttreatment orthodontic plaster casts were selected from the archives of the Orthodontic Department at the Indiana University School of Dentistry. Plaster models were scanned, saved as stereolithography files, and printed as physical models using three different three-dimensional (3D) printers: Makerbot Replicator (FDM), 3D Systems SLA 6000 (SLA), and Objet Eden500V (Polyjet). A digital caliper was used to obtain measurements on the original plaster models as well as on the printed resin models.
RESULTS: Comparison between the 3D printed models and the plaster casts showed no statistically significant differences in most of the parameters. However, FDM was significantly higher on average than were plaster casts in maxillary left mixed plane (MxL-MP) and mandibular intermolar width (Md-IMW). Polyjet was significantly higher on average than were plaster casts in maxillary intercanine width (Mx-ICW), mandibular intercanine width (Md-ICW), and mandibular left mixed plane (MdL-MP). Polyjet was significantly lower on average than were plaster casts in maxillary right vertical plane (MxR-vertical), maxillary left vertical plane (MxL-vertical), mandibular right anteroposterior plane (MdR-AP), mandibular right vertical plane (MdR-vertical), and mandibular left vertical plane (MdL-vertical). SLA was significantly higher on average than were plaster casts in MxL-MP, Md-ICW, and overbite. SLA was significantly lower on average than were plaster casts in MdR-vertical and MdL-vertical.
CONCLUSIONS: Dental models reconstructed by FDM technology had the fewest dimensional measurement differences compared to plaster models.

Entities:  

Keywords:  3D printing; Orthodontic models; Prototyping technology

Mesh:

Substances:

Year:  2018        PMID: 29509023      PMCID: PMC8288316          DOI: 10.2319/071117-460.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  14 in total

1.  Comparison of measurements made on digital and plaster models.

Authors:  Margherita Santoro; Scott Galkin; Monica Teredesai; Olivier F Nicolay; Thomas J Cangialosi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2003-07       Impact factor: 2.650

2.  Accuracy and reproducibility of dental replica models reconstructed by different rapid prototyping techniques.

Authors:  Aletta Hazeveld; James J R Huddleston Slater; Yijin Ren
Journal:  Am J Orthod Dentofacial Orthop       Date:  2014-01       Impact factor: 2.650

3.  Objective grading system for dental casts and panoramic radiographs. American Board of Orthodontics.

Authors:  J S Casko; J L Vaden; V G Kokich; J Damone; R D James; T J Cangialosi; M L Riolo; S E Owens; E D Bills
Journal:  Am J Orthod Dentofacial Orthop       Date:  1998-11       Impact factor: 2.650

4.  Comparison of linear measurements and analyses taken from plaster models and three-dimensional images.

Authors:  Betina Grehs Porto; Thiago Soares Porto; Monica Barros Silva; Renésio Armindo Grehs; Ary dos Santos Pinto; Shilpa H Bhandi; Mateus Rodrigues Tonetto; Matheus Coelho Bandéca; Lourdes Aparecida Martins dos Santos-Pinto
Journal:  J Contemp Dent Pract       Date:  2014-11-01

5.  Comparison of reconstructed rapid prototyping models produced by 3-dimensional printing and conventional stone models with different degrees of crowding.

Authors:  Wan Nurazreena Wan Hassan; Yusnilawati Yusoff; Noor Azizi Mardi
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-01       Impact factor: 2.650

Review 6.  3D printing in dentistry.

Authors:  A Dawood; B Marti Marti; V Sauret-Jackson; A Darwood
Journal:  Br Dent J       Date:  2015-12       Impact factor: 1.626

7.  3D Systems' Technology Overview and New Applications in Manufacturing, Engineering, Science, and Education.

Authors:  Trevor J Snyder; Mike Andrews; Mark Weislogel; Peter Moeck; Jennifer Stone-Sundberg; Derek Birkes; Madeline Paige Hoffert; Adam Lindeman; Jeff Morrill; Ondrej Fercak; Sasha Friedman; Jeff Gunderson; Anh Ha; Jack McCollister; Yongkang Chen; John Geile; Andrew Wollman; Babak Attari; Nathan Botnen; Vasant Vuppuluri; Jennifer Shim; Werner Kaminsky; Dustin Adams; John Graft
Journal:  3D Print Addit Manuf       Date:  2014-09-01       Impact factor: 5.449

8.  Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

Authors:  Fan Zhang; Kyung-Jin Suh; Kyung-Min Lee
Journal:  PLoS One       Date:  2016-06-15       Impact factor: 3.240

9.  Accuracy of three-dimensional printing for manufacturing replica teeth.

Authors:  Keun-Young Lee; Jin-Woo Cho; Na-Young Chang; Jong-Moon Chae; Kyung-Hwa Kang; Sang-Cheol Kim; Jin-Hyoung Cho
Journal:  Korean J Orthod       Date:  2015-09-23       Impact factor: 1.372

10.  Reliability and validity of intraoral and extraoral scanners.

Authors:  Helder B Jacob; Graydon D Wyatt; Peter H Buschang
Journal:  Prog Orthod       Date:  2015-10-27       Impact factor: 2.750

View more
  14 in total

1.  Influence of the three-dimensional printing technique and printing layer thickness on model accuracy.

Authors:  Zhe-Chen Zhang; Pei-Lun Li; Feng-Ting Chu; Gang Shen
Journal:  J Orofac Orthop       Date:  2019-06-06       Impact factor: 1.938

2.  [A method to evaluate the trueness of reconstructed dental models made with photo-curing 3D printing technologies].

Authors:  N Xiao; Y C Sun; Y J Zhao; Y Wang
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2019-02-18

3.  Accuracy of commercial intraoral scanners.

Authors:  Mattia Sacher; Georg Schulz; Hans Deyhle; Kurt Jäger; Bert Müller
Journal:  J Med Imaging (Bellingham)       Date:  2021-05-24

4.  Three-Dimensional (3D) Stereolithographic Tooth Replicas Accuracy Evaluation: In Vitro Pilot Study for Dental Auto-Transplant Surgical Procedures.

Authors:  Filiberto Mastrangelo; Rossella Battaglia; Dario Natale; Raimondo Quaresima
Journal:  Materials (Basel)       Date:  2022-03-23       Impact factor: 3.623

5.  In vitro accuracies of 3D printed models manufactured by two different printing technologies.

Authors:  Faruk Emir; Gulsum Ceylan; Simel Ayyildiz
Journal:  Eur Oral Res       Date:  2021-05-04

6.  Analogical and Digital Workflow in the Design and Preparation of the Emergence Profile of Biologically Oriented Preparation Technique (BOPT) Crowns over Implants in the Working Model.

Authors:  Guillermo Cabanes-Gumbau; David Soto-Peñaloza; Miguel Peñarrocha-Diago; María Peñarrocha-Diago
Journal:  J Clin Med       Date:  2019-09-12       Impact factor: 4.241

7.  Morphological validation of a novel bi-material 3D-printed model of temporal bone for middle ear surgery education.

Authors:  Jordan Chauvelot; Cedric Laurent; Gaël Le Coz; Jean-Philippe Jehl; Nguyen Tran; Marta Szczetynska; Abdelhadi Moufki; Anne-Sophie Bonnet; Cecile Parietti-Winkler
Journal:  Ann Transl Med       Date:  2020-03

8.  Comparison of Dental Stone Models and Their 3D Printed Acrylic Replicas for the Accuracy and Mechanical Properties.

Authors:  Marta Czajkowska; Ewa Walejewska; Łukasz Zadrożny; Monika Wieczorek; Wojciech Święszkowski; Leopold Wagner; Eitan Mijiritsky; Jarosław Markowski
Journal:  Materials (Basel)       Date:  2020-09-13       Impact factor: 3.623

9.  Evaluation of accuracy of 3-dimensional printed dental models in reproducing intermaxillary relational measurements: Based on inter-operator differences.

Authors:  Won-Joon Choi; Su-Jung Lee; Cheol-Hyun Moon
Journal:  Korean J Orthod       Date:  2022-01-25       Impact factor: 1.372

10.  Evaluation of the fused deposition modeling and the digital light processing techniques in terms of dimensional accuracy of printing dental models used for the fabrication of clear aligners.

Authors:  Samer T Jaber; Mohammad Y Hajeer; Tarek Z Khattab; Luai Mahaini
Journal:  Clin Exp Dent Res       Date:  2020-11-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.