Integration of reliability analysis into mini-plate fixation strategy used in human mandible fractures: Convalescence and healing periods.

Ghias Kharmanda1, Abdallah Shokry2, Mohamed Y Kharma3.   

Abstract

PURPOSE: The objective was to assess the reliability level of mini-plate fixation used in fracture mandibles in order to evaluate the structure stability in both convalescence and healing periods.
METHODS: In the convalescence period, the failure scenario is measured by the relative displacement between two fracture surfaces which should not exceed an acceptable value in order to obtain a good stability for rapid bone healing and to limit any trauma. However, in the healing period, it is the objective to obtain an acceptable rigidity. Hereby, the failure scenario is measured by the von Mises stresses being as indicator of mandible fractures.
RESULTS: During the surgery operation, some muscles can be cut or harmed and cannot operate at its maximum capability. Thus, there is a strong motivation to introduce the loading uncertainties in order to obtain reliable designs. A 3-dimensional finite element model was developed in order to study the negative effect caused by stabilization of the fracture. The different results were obtained when considering a clinical case of a 35-year-old male patient. The results show the importance of fixation of symphysis fracture by two I-plates with four holes. The structural reliability level was estimated when considering a single failure mode and multiple failure modes.
CONCLUSIONS: The integration of reliability concepts into mini-plate fixation strategy is considered a novel aspect. The reliability evaluation seams to be a reasonable asset in both convalescence and healing periods.

Entities:  

Mesh:

Year:  2017        PMID: 29507437

Source DB:  PubMed          Journal:  Acta Bioeng Biomech        ISSN: 1509-409X            Impact factor:   1.073


  2 in total

1.  Integrity of a Single Superior Border Plate Repair in Mandibular Angle Fracture: A Novel Cadaveric Human Mandible Model.

Authors:  Somsak Sittitavornwong; Douglas Denson; David Ashley; David Cruz Walma; Sarah Potter; Jonathan Freind
Journal:  J Oral Maxillofac Surg       Date:  2018-08-06       Impact factor: 1.895

2.  Efficient System Reliability-Based Design Optimization Study for Replaced Hip Prosthesis Using New Optimized Anisotropic Bone Formulations.

Authors:  Ghais Kharmanda; Samer Gowid; Elsadig Mahdi; Abdallah Shokry
Journal:  Materials (Basel)       Date:  2020-01-13       Impact factor: 3.623

  2 in total