Literature DB >> 29506340

Case of late hematoma after breast augmentation.

Leslie Kim1, Nikki Castel2, Fereydoun Don Parsa1.   

Abstract

We present a case report of a patient who experienced a late, spontaneous breast hematoma 26 years after primary breast augmentation. Late hematomas are a rare complication of breast augmentation with uncertain etiology. In this case, there was no trauma, calcifications, or implant rupture. We believe the patient's hematoma was secondary to erosion of a capsular vessel due to capsular contracture.

Entities:  

Keywords:  Breast implants; Contracture; Hematoma

Year:  2018        PMID: 29506340      PMCID: PMC5869420          DOI: 10.5999/aps.2016.01718

Source DB:  PubMed          Journal:  Arch Plast Surg        ISSN: 2234-6163


INTRODUCTION

Bleeding is a well-known and well-characterized acute complication following breast augmentation. This occurs in about 1% of patients [1-3]. Acute hematoma incidence is not significantly associated with type of implant surface texture or type of surgical procedure [2]. Conversely, late hematomas are a very rare complication of breast augmentation, documented by only 15–20 case reports. Here we describe a case in which capsular contracture appears to have contributed to the development of a late hematoma, in the absence of trauma, calcification, or implant rupture.

CASE

A 58-year-old woman, gravida 2 para 2, underwent a bilateral subglandular breast augmentation in August 1990 with polyurethane-coated, 325 mL silicone gel Replicon implants via inframammary incisions. The patient’s postoperative course was uneventful. The patient had soft breasts until 2011, when she began to experience capsular contractures bilaterally. A mammogram from 2015 suggested rupture of the right implant. In May 2016, the patient began to experience a gradual increase in size and distortion of the right breast, which was associated with mild pain. On physical examination, the patient had evidence of bilateral capsular contracture, Baker IV on the right and Baker III on the left. The right breast was firm and deformed (Figs. 1, 2). There were no palpable masses or lymphadenopathy.
Fig. 1.

Front view of the hematoma

Front view of the hematoma shows the swelling of the upper pole of the right breast with mild bluish discoloration.

Fig. 2.

Lateral view of the hematoma

Right lateral view of same patient shown in Fig. 1.

In May 2016, the patient underwent bilateral implant exchange with total capsulectomies. The capsule on the right was darkly pigmented and 150 mL of uncoagulated dark blood was evacuated from the capsule (Fig. 3). The implant was removed intact and total capsulectomy was performed. The capsule was strongly adherent to surrounding tissues and difficult to excise. There was an area of erosion in the medial aspect of the capsule as shown in Fig. 4. No calcifications were noted. The old implants were exchanged for 322 mL textured gel implants (Allergan).
Fig. 3.

Right opened capsule

The right capsule has been opened with a stab incision, demonstrating outflow of uncoagulated blood.

Fig. 4.

Right opened capsule from interior view

The right capsule is shown from the implant side. The red arrow is pointing to the area of vascular erosion and bleeding.

The capsule on the left was pale and no blood or fluid collections were noted. The implant was removed intact and total capsulectomy was performed without difficulty. The left capsule was barely adherent to the underlying pectoralis muscle and overlying breast tissue. It was easy to excise with minimal blood loss. The removed capsule, shown in Fig. 5, showed mild capsular calcifications primarily involving the anterior surface of the implant.
Fig. 5.

Left opened capsule

The left breast capsule as seen from inside. The hemostat points to a limited area of calcification on the anterior surface. No vascular erosion or bleeding were noted.

DISCUSSION

Late complications of breast augmentation with implants are varied, but fairly rare, including anaplastic large T-cell lymphoma, late seroma, and late hematoma. They often present as late progressive enlargement or deformation of the affected breast [4-7]. The late complications of breast augmentation with implants are varied, but fairly rare, including anaplastic large cell lymphoma, late seroma, and late hematoma. The etiology of late hematoma following breast augmentation has been poorly characterized due to its rarity. The first case was reported by Georgiade et al. [8] in 1979. They proposed that corticosteroid usage at time of placement was responsible for the erosion and subsequent hematoma. Currently, general consensus holds that late hematomas most likely result from erosion of capsular vessels due to trauma, inflammation, microfracture of the capsule, or friction of implant against the capsule [9-12]. In one case, trauma in the form of amorous squeezing was implicated [13]. In this case report, capsular contracture appears to have been the primary mechanism for the late hematoma. Previous case reports have suggested that polyurethane coating, as in this case, may provoke an intense inflammatory reaction which would subsequently place patients at higher risk for developing capsular contracture and, possibly, late hematoma [9]. However, it has since been shown that polyurethane-coating actually decreases the risk of capsular contracture development [14]. In this patient, gradual disintegration of the protective polyurethane coating may have contributed to the development of capsular contracture, culminating in late hematoma development 26 years later due to pressure against capsular vessels (Fig. 4). In conclusion, polyurethane-coated implants have been discontinued in the United States since 1992, however, they are still present in a number of patients. Though polyurethane coating is protective against capsular contracture, as the coating ages and disintegrates, many more patients may begin presenting with complaints of capsular contracture. In rare cases, they may also present with late hematoma likely due to capsular vascular erosion.
  14 in total

1.  Late hematoma after aesthetic breast augmentation with saline-filled, textured silicone prosthesis.

Authors:  Hung-Tao Hsiao; Kwang-Yi Tung; Chung-Shu Lin
Journal:  Aesthetic Plast Surg       Date:  2002 Sep-Oct       Impact factor: 2.326

2.  Late unilateral hematoma after breast augmentation.

Authors:  Walter Peters; Victor Fornasier; David Howarth
Journal:  Plast Surg (Oakv)       Date:  2014       Impact factor: 0.947

Review 3.  Anaplastic large T-cell lymphoma and breast implants: a review of the literature.

Authors:  Mark Jewell; Scott L Spear; Joan Largent; Michael G Oefelein; William P Adams
Journal:  Plast Reconstr Surg       Date:  2011-09       Impact factor: 4.730

4.  Late development of hematoma around a breast implant, necessitating removal.

Authors:  N G Georgiade; D Serafin; W Barwick
Journal:  Plast Reconstr Surg       Date:  1979-11       Impact factor: 4.730

Review 5.  Update on anaplastic large cell lymphoma in women with breast implants.

Authors:  Walter Peters
Journal:  Plast Surg (Oakv)       Date:  2014       Impact factor: 0.947

6.  Polyurethane-coated breast implants revisited: a 30-year follow-up.

Authors:  Nikki Castel; Taylor Soon-Sutton; Peter Deptula; Anna Flaherty; Fereydoun Don Parsa
Journal:  Arch Plast Surg       Date:  2015-03-16

7.  Late recurrent capsular hematoma after augmentation mammaplasty: case report.

Authors:  Schiavon Mauro; Fraccalanza Eugenio; Baraziol Roberto
Journal:  Aesthetic Plast Surg       Date:  2005-03-17       Impact factor: 2.326

8.  Late hematoma after breast implantation.

Authors:  Michael Brickman; Natalie N Parsa; Fereydoun Don Parsa
Journal:  Aesthetic Plast Surg       Date:  2004-06-01       Impact factor: 2.326

Review 9.  Amorous squeezing of the augmented breast may result in late capsular hematoma formation: A report of two cases (and a review of English-language literature on late hematoma formation in the augmented breast).

Authors:  A L van Rijssen; Han Wilmink; Jan J van Wingerden; Berend van der Lei
Journal:  Ann Plast Surg       Date:  2008-04       Impact factor: 1.539

Review 10.  Systematic review of the effectiveness of polyurethane-coated compared with textured silicone implants in breast surgery.

Authors:  Paula J Duxbury; James R Harvey
Journal:  J Plast Reconstr Aesthet Surg       Date:  2016-01-19       Impact factor: 2.740

View more
  3 in total

Review 1.  Current Concepts in Capsular Contracture: Pathophysiology, Prevention, and Management.

Authors:  Tyler Safran; Hillary Nepon; Carrie K Chu; Sebastian Winocour; Amanda M Murphy; Peter G Davison; Tassos Dionisopolos; Joshua Vorstenbosch
Journal:  Semin Plast Surg       Date:  2021-07-13       Impact factor: 2.195

2.  Breast implant seroma: A SARS-CoV-2 mRNA vaccine side effect.

Authors:  Françoise Kayser; Hadrien Fourneau; Olivier C Mazy; Stéphane Mazy
Journal:  J Clin Ultrasound       Date:  2021-08-18       Impact factor: 0.869

3.  Delayed unilateral hematoma after reconstructive and aesthetic breast surgery with implants in Asian patients: two case reports.

Authors:  Jong Ho Lee; Hyun Ki Hong; Won Hwa Kim; Hye Jung Kim; Jeeyeon Lee; Ho Yong Park; Jung Dug Yang; Joon Seok Lee
Journal:  Gland Surg       Date:  2021-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.